1 minute read

10.1.3 Determining full load

Order number Date Valid from serial number T-code

232020-040 2006-06-19 3 300 000- 805, 813, 830

•Important: Before full load (or any other weight) can be calibrated, any previous calibration points must be deleted. If this is not done, the scale may exhibit erratic behaviour for certain weight graduation ranges. •Press and hold the “PT” button for 18 seconds to access the calibration menu. •Place a load on the pallet truck scale equivalent to the truck’s maximum load and enter the weight using the arrow keys. •Press the “Enter” button to confirm the entered weight. The indicator then automatically calibrates the scale guided by the weight on the forks. •Press “Enter” once to return to normal weighing mode.

NOTE:

In practice, recalibration is generally performed by the customer using a single, known weight, e.g. a pallet that has been weighed on another scale.

NOTE:

When the power to the indicator is switched on, a calibration number appears briefly in the display. This number changes automatically after each calibration. With pallet trucks with commercial weighing status, this number is recorded by an authorised inspector to enable them to determine whether any subsequent recalibration has been performed by a non-authorised individual.

Checking the calibration number

Switch off the scale and then switch it on again. The indicator shows the following information: -8888.8 (test of LCD segment) -P 7.3 (software version) -1342 (calibration number) -1234.5 (current weight, normal weighing mode).