Manitou Telehandler MVT 665 MVT 675 Repair Manual 547654 - PDF DOWNLOAD

Page 34

MVT 665 - MVT 675

R E PA I R M A N UA L

HYDRAULICS PRESSURE CHECKING AND CONTROL FOR PISTON PUMP AND LOAD SENSING DISTRIBUTOR OF MOVEMENTS Use a 0-600 bar (0-8700 PSI) pressure gauge for checking the system pressures. Connect pipe rif. 72340 and pressure gauge ref. 58179 to the pressure test connection.

STAND-BY PRESSURE - With internal combustion engine at minimum speed, without making any movements. - Ensure that pressure gauge “M” shows 22 bar (314 PSI). Adjustment, if necessary: use the capacity adjustment screws “F” remove the cap using a 17 mm wrench unlock the lock nut using a 17 mm wrench adjust the required value, using a 3 mm socket head wrench on the adjustment screws turning the adjustment screws clockwise increases the stand-by pressure turning the adjustment screws anticlockwise decreases the stand-by pressure

PISTON PUMP MAXIMUM PRESSURE (To be checked only during the first startup of the piston pump) - Completely tighten the pressure cut-off valve “T” on the load sensing distributor. - With the internal combustion engine operating at medium-high speed (2000 min-1), perform end-of-travel with arm raised. - Ensure that pressure gauge “M” shows 300 bar (4286 PSI). Adjustment, if necessary: use the pressure adjustment screws “D” remove the cap using a 17 mm wrench unlock the lock nut using a 17 mm wrench adjust the desired value, using a 3 mm socket head wrench on the adjustment screw turning the adjustment screw clockwise increases the maximum pressure turning the adjustment screw anticlockwise decreases the maximum pressure

Page

29


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Manitou Telehandler MVT 665 MVT 675 Repair Manual 547654 - PDF DOWNLOAD by www.heydownloads.com - Issuu