MACHINE OPERATIONS AND CONTROLS

Check Oil Level in PTO Case, Add Oil

WARNING Parts and oil are at high temperature immediately after the engine is stopped and may cause serious burns. Wait for the oil temperature to go down before performing this operation.

NOTICE Park the machine on flat ground and stop the engine. After waiting for more than 30 minutes after stopping the engine, check the oil level. 1. Open the cover at the front of the engine room and check the level with dipstick (F).

2. The oil level should be between the L and H marks. If necessary, add oil at the dipstick guide hole.

Check Air Cleaner For Clogging 1. Confirm that the air cleaner clogging monitor does not light up. 2. If it lights up, immediately clean or replace the element. For details of method of cleaning the element, see "CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT (PAGE 4-19)".