FAILURE CODE [DR81MA]
40 TROUBLESHOOTING
FAILURE CODE [DR81MA] Action level
Failure code
E03 Detail of failure
Failure
DR81MA
Option Setting Mismatch (Translator Controller) (Retarder controller system)
When starting switch is turned to ON position, the option setting information sent from translator controller differs from that stored in the retarder controller.
Action of conNone troller Phenomenon on machine
•
The option system caution lamp lights up and the alarm buzzer sounds.
•
Even if cause of failure is eliminated, machine does not become normal until starting switch is turned to OFF position.
Related inforMethod of reproducing failure code: Turn the starting switch to the ON position. mation No.
Cause
Procedure, measurement location, criteria and remarks
1
Defective translator controller and retarder controller
The option setting of the translator controller or the retarder controller is probably incorrect. After replacing the translator controller or the retarder controller, set the options correctly. For details, see TESTING AND ADJUSTING.
2
3
Open circuit in wiring har- 1. ness 2.
Starting switch: OFF Disconnect the connector TLC3. Connect a T-adapter to the female side.
(wire breakage or defective contact)
Resistance
Defective translator controller
If no failure is found by the checks above, the translator controller is defective. (Because this is an internal defect, troubleshooting cannot be done.)
Between TLC3 (female) (20) and ground
Max. 1Ω
Circuit diagram of option setting
40-14
HD785-7