Information Center Electronic Display
Screens
Note: Values may not display for all parameters, depending upon installed options and equipment.
Table 7: Status, Maintenance and Error Code Screens
Display Mode Description
Status Screens
Dual Gauge Display
A.Fuel level.
B.Engine coolant temperature.
C.Accumulated operation time.
Note: Time is displayed in hours, and accumulates when the engine is running.
D.Amber error condition warning. Causes DM1/DM2 errors screen(s) to display. See page42.
E.Red critical error warning. Causes DM1/DM2 errors screen(s) to display. See page42.
F.Engine coolant temperature amber warning region. Indicates elevated coolant temperature.
G.Engine coolant temperature red stop warning region. Indicates serious coolant overheating condition.
Note: Running the engine in an overheated condition can damage the engine.
H.Fuel level amber warning region. Indicates low fuel level.
I.Fuel level red stop region. Indicates almost empty fuel tank.
Quad Gauge Display
Displays four different status parameters simultaneously. To change the displayed parameters, press and hold the ok button (N, Figure 20) until orange bar (T) displays. Press the left/right side of navigation rocker button (M, Figure 20) to select the parameter and press the top/bottom of navigation rocker button to change the selected parameter. Press the ok button again to dismiss orange bar (T).
Single Gauge Display
Displays single real time operating parameters. Switch between parameters using the navigation button (M, Figure 20). Used for various functions, depending upon screen and context.
Table 7: Status, Maintenance and Error Code Screens
Regeneration Screens (DPF Models)
These screens are associated with Diesel Particulate Filter (DPF) regeneration procedures and maintenance. See “Diesel Particulate Filter (DPF) Regeneration Procedures (DPF Models)” on page74.
Secondary Screens
All Secondary Screens
Secondary screens are accessed by holding down the ok button (N, Figure 20) for 10 seconds while the Dual Gauge Display screen is displayed. Press the left/right side of navigation rocker button (M, Figure 20) to switch between secondary screens.
Revision Screen
Displays information center electronic display software information.
Units Screen
Press the top/bottom of navigation rocker button (M, Figure 20) to switch between SAE or metric units for values displayed in screens.
Language Screen