02 Transmission/clutch "Revershift" hydraulic reverser
Measurements and checks Control of general lubrication pressure Test conditions: – Engine running at 2 200 rpm. – Transmission oil temperature: 60°C.
T
1
HYDRO TESTER
Fig. 17
394msm2k
– Connect the tester #00 0178 310 0 onto the (1) fitting of the lubrication feed. The pressure should be approximately 3 bar.
Arion 430-410 – 12.2009 – GB