08 Power and control outputs Front power take-off

Measurements and checks Checking low pressure of the front power take-off Test conditions: – Engine running at 2 200 rpm. – Casing oil temperature at 20°C.

1 HYDRO TESTER

Fig. 2

a2108004

– Fit the pressure sensor of the 00 0178 310 0 kit onto the low pressure connector (1). – Connect tester Nr.00 0178 310 0 to the pressure sensor. – Measure the pressure which must be 21 bar.