MEASUREMENTS AND CHECKS

Checking low pressure of the front power take-off

Test conditions: – Engine running at 2200 rpm. – Casing oil temperature at 20°C.

HYDRO TESTER HYDRO TESTER 1

a2108004

– Fit the pressure sensor of the 0001783100 kit onto the low pressure connector (1). – Connect tester Nr.0001783100 to the pressure sensor. – Measure the pressure which must be 21 bar.

Fig. 2

Checking pressure of the front power take-off command

Test conditions: – Engine running at 2200 rpm. – Casing oil temperature at 20°C.

HYDRO TESTER HYDRO TESTER 1

a2108003

– Fit the pressure sensor of kit No.0001783100 onto the pressure tap (1). – Connect tester Nr.0001783100 to the pressure sensor. – Actuate the "S113" front power take-off engaging command contact. – Measure the pressure which must be 21 bar.

Fig. 3