1 minute read

Alternator

Error Code Flashes Error Reason Result

1 Overspeed of the Then engine ran at over 3000 The throttle shuts down engine rpm for more than 0.3 seconds and will not operate until restart.

Advertisement

2 Input signal from The voltage of the input signal The throttle shuts down the accelerator from the accelerator sensor and prevents the starter motor sensor is out of exceeded limitation. from activating.Will not operate spec The Input signal from the until restart. accelerator sensor does not increase when the idle switch on the carburetor is off.

3 The idle position The idle position sensing switch The maximum speed is sensing switch on on the carburetor stays at on limited to 150 rpm. the carburetor is when the input signal from not correct accelerator sensor opens more than 1/2.

4 The throttle close During calibration, the ECU did See #2 above. sensing switch on not receive an on-signal from the carburetor is the throttle close-sensing switch. not correct

5 The throttle open During calibration, the ECU did See #3 above. sensing switch is not receive an on-signal from not correct the throttle open-sensing switch.

6 The stepping The ECU received a throttle See #1 above. motor is not close or open signal from the correct sensing switch during the normal throttle lever stroke (expect high or low idle).

7 The revolution No revolution signal pulse from See #1 above. signalpulse from the distributor while the voltage the distributor is of the “L”terminal of the not correct alternator is in the normal operating range.

8 Alternator is not The voltage of the “L”terminal See #1 above. correct of the alternator remains lower than limitation over 30 seconds when a revolution signal pulse exists.

-114-

Ignition System and Distributor

Removal and Installation

Removal steps

A A 1.Spark Plug Wires A A 2.Ignition Coil Wire B B 3.Coil C C 4.Distributor 5.Gasket

D 6.Spark Plugs 4

5 2

3

6

-115-

This article is from: