1 minute read

HOIST BRAKE SOLENOID VALVE

• Swing Break Valve (Q 17.0)

A “1” at this output activates Swing Brake Solenoid Valve and releases brake.

Hoist Brake Solenoid Valve

• Hoist Drive Minimum Current (DB3410.dbx0.4) • Hoist Drive On (To SiBas) (Q 24.1)

This is a command bit to SiBas to turn on the Hoist drive.

• Hoist Brake Valve (Q 16.0)

A “1” at this output activates Hoist Brake Solenoid Valve and releases brake. • Hoist Speed < 2.5 Hz (DB3410.dbx1.7) • Hoist In Regeneration (DB3418.dbx1.1) • Hoist Gate Blocked (DB3418.dbx0.0)

The Hoist Gate Blocked signal from SiBas indicates either a Hoist drive fault or Hoist drive is not on.

• Machine Stop Pushbutton (I 33.0)

• Power Off Emergency Pushbutton (I 33.1)

POEB button is a NC switch which is on when no emergency..