Replacing a battery

Remove the old battery.

Install new anti-sulphate pellets, reconnect positive cable ends to positive terminals and then negative cable ends to negative terminals. Install the terminal protection caps. Install the protection plate. CD00E191

!

WARNING: Do not invert battery terminals. Connect positive cable ends to positive (+) terminals and negative cable ends to negative terminals (-).

!

WARNING: Batteries give off explosive gases. Keep all naked flames, sparks and cigarettes away. Ensure adequate ventilation when charging batteries or when using in a confined place. Always protect your eyes when working near batteries.

!

WARNING: The electrolyte in the batteries can cause serious burns. Batteries contain sulphuric acid. Avoid contact with skin, eyes and clothing. Antidote : XTERNAL : rinse thoroughly with water and remove soiled clothes. INTERNAL : do not induce vomiting. Rinse the mouth out with water. Seek medical advice. EYES : rinse thoroughly with water for 15 minutes and seek medical advice.

!

WARNING: Never touch battery terminals with the hands as electrolysis can take place within the human body and damage vital organs.

215

TRIM THIS EDGE RIGHT PAGE

TRIM THIS EDGE

Remove the protection plate, disconnect cables (negative terminals) and then cables (positive terminals). Remove the anti-sulphate pellets.

Template Name: OM_1_col Template Date: 1994_04_29

Clean the cables and battery terminals and coat them with grease.

Alt= to hide template information Alt+ to display template information

Install the new battery.