Operator’s 履带起重机操作手册 Manual for Crawler Crane

At least 33ft (10 m) in the case of a high-voltage cable, or if uncertain about the voltage of the underground cable.

4)

Inform the relevant power station of the accident. Prevent access to the area around the fault location: fence off an area with a radius of 33ft (10 m).

5) d)

Thoroughly inspect the machine before resuming operation.

If the control no longer functions, use the radio or call 1)

To everyone in the vicinity not to come any closer to or touch the machine, the hoisting rope or load; tell them to keep at least 33ft (10 m) away.

2)

To arrange for the power lines to be switched off by the relevant power station.

CAUTION Only leave the driver’s cab if you have reliable confirmation that the underground cable has been switched off. Safety Guidelines

DANGER

安 全 准 则

Even an underground cable that has been switched off can be switched on again manually, or by automatic safety devices, for fault detection purposes.