1 minute read
Model 9600/9700 Swing-Reach ® Lift Truck
Section 8.Theory of Operation
Pinout Matrix
212JPT24-6DGND B– for Mini Lift Pressure Transducer.Measure B+ at TP1 to verify connections. Then check for <0.5V wrt TP4.
TMMini Lift Pressure Transducer
213JPT24-7DGND B– for Custom In T2.
214JPT24-8DGND B– to the optional End-of-Aisle Sensor (S46B) at S46B-8. It is then routed through the switch module to S46B-7 to S46A-8.
215JPT24-9DGND B– to the optional End-of-Aisle Sensor (S47B) at S47B-8. It is then routed through the switch module to S46B-7 to S46A-8. It is connected on the TM through Fuse FU13 to JPS14-3 and 4, and on to TP4. There is no harness wiring connected at this point.
TMCustom In T2
TMS46A/B
TMS47A/B
217JPT24-11DGND B– for the Load Handler Motor Temp Sensor.
216JPT24-10DGND B– for the Main Lift Pressure transducer.Measure B+ at TP1 to verify connections. Then check for <0.5V wrt TP4.
TMMain Lift Pressure transducer
TMLoad Handler Temp Sensor
218JPT24-16VMIDO Jumper used to identify module as the TM.<0.5VTMTM
219JPT24-17SENSOR 2Input voltage to the TM. It is generated by either S47A or S47B when one or both of them detect the presence of a floor magnet. SENSOR 2 is used along with SENSOR 1 (JPT12-10) to determine if the truck is in or out of the aisle. This information is used to control travel speed based on truck location and the position of the AUTO/MAN switch.
220JPT24-18MAIN LIFT PRESS.
Analog DC voltage that varies directly with the weight on the carriage. Approx. 1V per 1000 lb. (453 kg). It is necessar y to have the TM supply approx. 12V as well as DGND in order for the transducer to function correctly.
221JPT24-19MINI LIFT PRESS.Analog DC voltage that varies directly with the weight on the mini-mast. Approx. 1V per 1000 lb. (453 kg). It is necessar y to have the TM supply approx. 12V as well as DGND in order for the transducer to function correctly.
222JPT24-20BATTERY GATE RT
Input voltage to the TM from the optional Battery Gate Prox 2 (S58). The proximity switch is used to detect the right battery gate is correctly installed. Travel is inhibited when the switch does not detect a correctly installed gate.
Magnet not sensed: >4V
Magnet sensed: <1V
S47A/BTM
Forks Fully Lowered: 1V
Main Lift Pressure Transducer
TM
Forks Fully Lowered: 1V
Mini Lift Pressure Transducer
TM installed: <1V Not installed: >4V
Publication: 1089040, Issued: 08 Apr 2016 8-35