RG 200.B
OPERATOR´S COMPARTMENT AIR CONDITIONING, HEATING AND AIR RECIRCULATION SYSTEM 1-
B4 - AIR CONDITIONING SWITCH ON/OFF button for the compressor for environment cooling.
OPERA TION OPERATION
The air conditioning control panel located inside the cab is fitted to the right over the operator´s console. Therefore, for operation of the air conditioning, recirculation or heating systems, follow these steps:1- Turn starter key (8) to ON, to activate basic machine functions and start the engine. 2- Turn cab fan switch (1) on to high speed position (3). 3- Finally, push the system operating button B2,B3 or B4 B4. A- STARTER SWITCH
2 - MAINTENANCE Maintenance of the air conditioning / heating system is in three points.
B 1-
CAB FAN SWITCH This is a rotary type switch, with four positions, as follows:
A- Evaporator box air filter B- Air compressor C- Condenser
0 - OFF 1 - Low speed 2 - Medium speed 3 - High speed B 2-
CAB HEATING SWITCH
The machine has a system that uses the heat absorbed in the engine cooling. To switch it on, keep the engine coolant valve permanently open, as the engine water recirculation for heating is done through the solenoid valve when the heating switch is turned on. ON/OFF button to stard and end the operation of the heating system and front and rear glass defroster. B 3-
AIR RECIRCULATION SWITCH ON/OFF button to stard and end the operation of the air recirculation or air renewal system.
Read the SAFETY RULES on the preceding pages for machine protection and the safety of employees
44