Control and operation

Operating manual

Operating and control elements

Should more than two symbols be shown, so the clock is not displayed any more and up to four symbols can be shown at the same time in the field SY. If more than 4 symbols must be shown, then every 10 seconds, the symbols move to the left by one symbol. See the list of the possible symbols in section "Warning symbols in the SY field", further in this chapter.

EC field The EC window displays the error codes for electrical faults which occur in the excavator's electronics system (line errors, sensor errors etc.). A maximum of 7 error codes are displayed simultaneously. If there are more than these 7 errors present, an arrow which points to where the other error codes are located will be displayed next to the error code window. Press the Up or Down button. The error code list is shifted in the selected direction. See the complete list of the error codes in section "Error codes charts", in chapter 4.

INF field The INF field displays temporary information in graphic form. If more than 3 symbols are to be displayed, the symbols will shift one symbol to the left approx. every 10 seconds. The information is displayed in graphic or text form and indicates specific operating states on the machine (also see the section "Information symbols in the INF field", further in this chapter).

TI field The machine operating hours and the daily operating hours counter are displayed in this field at the bottom right of the screen. During the start-up phase, the operator will be alerted about a possible up-coming service time, by a graphic symbol and an hour indication displayed instead of the machine hour-meter during about 8 seconds. The symbol ® is displayed when an external flow limitation is activated (see the description of the menu "Info In/Outputs", further in this chapter). The symbol " " indicates that no external flow limitation is actually activated. But an internal flow limitation (travel, swing,...) may be activated. In this field can also be indicated the denomination (for example HM2000) of the option which is actually assigned to the external flow limitation input I1 (see the description of the menu "Set option", further in this chapter).

Control of the screen at error recognition In case a new operating fault displayed in the field SY is recognized, the presentation will return to the main screen, and the relevant symbol is displayed. Depending on the fault (level of urgency), the buzzer will sound either continuously or in short consecutive bursts. At the same time the symbol "acknowledge error" will be displayed in the INF field.

copyright by

3 - 16

MJFCIFSS

R 974 C / 10069856


Turn static files into dynamic content formats.

Create a flipbook

Articles inside

5.2Cleaning machine

1hr
pages 290-394

5Maintenance

2min
pages 287-289

Troubleshooting

1min
pages 284-285

Troubleshooting

6min
pages 278-283

Troubleshooting

10min
pages 266-271

4Troubleshooting

3min
pages 263-265

Control and operation

1min
pages 260-262

Control and operation

3min
pages 256-259

Control and operation

2min
pages 254-255

Control and operation

4min
pages 248-253

Control and operation

2min
pages 246-247

Control and operation

1min
pages 244-245

Control and operation

10min
pages 230-243

Control and operation

5min
pages 224-229

Control and operation

4min
pages 220-223

Control and operation

8min
pages 212-219

Control and operation

1min
pages 210-211

Control and operation

2min
pages 206-209

Control and operation

1min
pages 204-205

Control and operation

1min
pages 202-203

Control and operation

3min
pages 198-201

Control and operation

3min
pages 194-197

Control and operation

1min
pages 192-193

Control and operation

6min
pages 186-191

Control and operation

1min
pages 184-185

Control and operation

4min
pages 180-183

Control and operation

1min
pages 178-179

Control and operation

2min
pages 176-177

3.4Working with the machine

4min
pages 170-175

the machine into operation

14min
pages 157-169

Control and operation

1min
pages 156-157

Control and operation

12min
pages 142-155

Control and operation

3min
pages 138-141

Control and operation

1min
pages 136-137

Control and operation

2min
pages 134-135

Control and operation

9min
pages 126-133

Control and operation

4min
pages 120-125

Control and operation

1min
pages 118-119

Control and operation

6min
pages 112-117

Control and operation

8min
pages 106-111

Control and operation

1min
pages 104-105

Control and operation

1min
pages 102-103

Control and operation

1min
pages 100-101

Control and operation

3min
pages 96-99

Safety instructions, Signs on the machine

1min
pages 86-87

Safety instructions, Signs on the machine

4min
pages 78-81

Safety instructions, Signs on the machine

3min
pages 76-77

2Safety instructions, Signs on the machine

28min
pages 61-75

1Product description

1min
pages 11-15
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Liebherr Hydraulic excavator R 974 C Operating manual 30724 - PDF DOWNLOAD by www.heydownloads.com - Issuu