Error code list
E 090Fuel temperature not being monitored. Short circuit to earthConsult LIEBHERR customer service.
E 091Short circuit +24V or cable break
E 092Fuel pressure not being monitored. Short circuit +24VConsult LIEBHERR customer service.
E 093Short circuit to earth or cable break
E 094Fuel pressure in rail 1 not being monitored. Short circuit +24VConsult LIEBHERR customer service.
E 095Short circuit to earth or cable break
E 096Fuel pressure in rail 2 not being monitored. Short circuit +24VConsult LIEBHERR customer service.
E 097Short circuit to earth or cable break
E 098D+ default on the alternatorConsult LIEBHERR customer service.
E 099Alternator default
E 100Engine RPM not being monitored.
The value registered by the transmitter B12-1 is impossible.
Switch to emergency control speed adjustment S71 and S72 and emergency operation work pumps Y50, consult LIEBHERR customer service.
E 101Engine RPM not being monitored. The value registered by the transmitter B12-2 is impossible.
Switch to emergency control speed adjustment S71 and S72 and emergency operation work pumps Y50, consult LIEBHERR customer service.
E 102Engine can not be started.Cranckshaft synchronisation default Consult LIEBHERR customer service.
E 103Camshaft transmitter defaultConsult LIEBHERR customer service.
E 104The value registered by the camshaft transmitter is impossible.
Consult LIEBHERR customer service.
E 105Engine can not be started.Camshaft synchronisation Consult LIEBHERR customer service.
E 106Cold start command defaultUnit 2 of cold start command over current Consult LIEBHERR customer service.
E 107Unit 2 of cold start command default
E 108Open load for Unit 2 of cold start command
E 109Hardware CAN1 defaultConsult LIEBHERR customer service.
E 110CAN1 data impossible or time out
E 111Injector A1 defaultConsult LIEBHERR customer service.
E 112Injector A1 error BIP / FZM
E 113Injector A2 defaultConsult LIEBHERR customer service.
E 114Injector A2 error BIP / FZM
E 115Injector A3 defaultConsult LIEBHERR customer service.
E 116Injector A3 error BIP / FZM
E 117Injector A4 defaultConsult LIEBHERR customer service.
E 118Injector A4 error BIP / FZM
E 119Injector B1 defaultConsult LIEBHERR customer service.
E 120Injector B1 error BIP / FZM
E 121Injector B2 defaultConsult LIEBHERR customer service.
E 122Injector B2 error BIP / FZM
E 123Injector B3 defaultConsult LIEBHERR customer service.
E 124Injector B3 error BIP / FZM
E 125Injector B4 defaultConsult LIEBHERR customer service.
E 126Injector B4 error BIP / FZM
E 127Parameter default bank AConsult LIEBHERR customer service.
E 128Parameter default bank B
E 129Fuel pressure in rail 1 not being monitored. Short circuit to earth or cable break Consult LIEBHERR customer service.
E 130Short circuit +24V
E 131Incoherent signal
E 132Fuel pressure in rail 2 not being monitored. Short circuit to earth or cable break Consult LIEBHERR customer service.
E 133Short circuit +24V
E 134Incoherent signal
E 135Circuit 5 Volt - REF1
E 136Circuit 5 Volt - REF2
E 137Circuit 5 Volt - REF3
E 138Circuit 5 Volt - REF4
E 139Circuit 5 Volt - REF5
E 140Possible starting difficulties at low ambient temperatures
Left heater flange R51-1 is defective
E 141Right heater flange R52-1 is defective
E 219Possibly incorrect function of the travel pedals U22/U23
The sensors B40/B45 are active, even though the pedals U22/U23 are not actuated . Travel pedals U22/U23 wrong adjusted or defective
Consult LIEBHERR customer service.
E 220Possibly incorrect function of the pressureless lowering
E221 to E223
E 224 to
E 227
Possibly incorrect function of the servo control for additional movement
Short circuit to ground or to +24V in the load circuit of Y401
Short circuit to ground or to +24V in the load circuit of the commutation solenoid valve
Short circuit to ground or to +24V in the load circuit
Check, if necessary replace the heater flange R51-1 .
Check, if necessary replace the heater flange R52-1 .
Check the travel pedals for proper function, if necessary readjust or replace pedals.
Check, if necessary repair the commutation solenoid valve Y401 and its connecting circuit
Check, if necessary repair the commutation solenoid valve for additional movement and its connecting circuit
Check, if necessary repair the load circuit
Error code EffectCauseMeasure / remedy
E 228Possibly incorrect function of the servo control circuit
E 229Possibly incorrect function of the servo control circuit
E230, E231 and E233
Possibly incorrect function of the servo control for additional movement
E 232Possibly incorrect function of the pressureless lowering
E 234Possibly incorrect function of the servo control for swing left
E 235Possibly incorrect function of the servo control for swing right
E220 to E235 Simultan eously
E 236
No or incorrect function of the servo control
Short circuit to ground or to +24V in the load circuit of the commutation solenoid valve Y 369A
Short circuit to ground or to +24V in the load circuit of the commutation solenoid valve Y 370B
Short circuit to ground or to +24V in the load circuit
Short circuit to ground or to +24V in the load circuit Y109
Short circuit to ground or to +24V in the load circuit Y150
Short circuit to ground or to +24V in the load circuit Y151
Missing 24V supply of the servo control plate U46/D
Check, if necessary repair the commutation solenoid valve Y369A and its connecting circuit
Check, if necessary repair the commutation solenoid valve Y370B and its connecting circuit
Check, if necessary repair the load circuit
Check, if necessary repair the commutation solenoid valve Y109 and its connecting circuit
Check, if necessary repair the commutation solenoid valve Y150 and its connecting circuit
Check, if necessary repair the commutation solenoid valve Y151 and its connecting circuit
Check 24V supply circuit, r(epair as necessary (Fuse F153, connectors X830-1 & X830-3, .)
Possibly incorrect function of the servo control for lowering boom.
E 237Broken wire in the load circuit to regulation solenoid valve Yr1A1
E 238
Possibly incorrect function of the servo control for lifting boom.
Short circuit to ground or to +24V in the load circuit Yr1-A1Check, if necessary repair the regulation solenoid valve Yr1A1 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-B1Check, if necessary repair the regulation solenoid valve Yr1B1 and its connecting circuit
E 239Broken wire in the load circuit to regulation solenoid valve Yr1B1
E 240
Possibly incorrect function of the servo control for bucket tilting out.
E 241Broken wire in the load circuit to regulation solenoid valve Yr1A2
E 242
Possibly incorrect function of the servo control for bucket tilting in.
Short circuit to ground or to +24V in the load circuit Yr1-A2Check, if necessary repair the regulation solenoid valve Yr1A2 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-B2Check, if necessary repair the regulation solenoid valve Yr1B2 and its connecting circuit
E 243Broken wire in the load circuit to regulation solenoid valve Yr1B2
E 244
Possibly incorrect function of the servo control for travelling left backwards.
E 245Broken wire in the load circuit to regulation solenoid valve Yr1A3
Short circuit to ground or to +24V in the load circuit Yr1-A3Check, if necessary repair the regulation solenoid valve Yr1A3 and its connecting circuit
E 246
Possibly incorrect function of the servo control for travelling left foreward.
E 247Broken wire in the load circuit to regulation solenoid valve Yr1B3
E 248
Possibly incorrect function of the servo control for retracting or extending stick.
Short circuit to ground or to +24V in the load circuit Yr1-B3Check, if necessary repair the regulation solenoid valve Yr1B3 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-A4Check, if necessary repair the regulation solenoid valve Yr1A4 and its connecting circuit
E 249Broken wire in the load circuit to regulation solenoid valve Yr1A4
E 250
Possibly incorrect function of the servo control for extending or retracting stick.
E 251Broken wire in the load circuit to regulation solenoid valve Yr1B4
E 236 to
E 251 Simultan eously
E 252
No or incorrect function of the servo control
Short circuit to ground or to +24V in the load circuit Yr1-B4Check, if necessary repair the regulation solenoid valve Yr1B4 and its connecting circuit
Missing 24V supply of the servo control plate U48-1/A , connector X840-3
Check 24V supply circuit, r(epair as necessary (Fuse F151, connector X840-3, .)
Possibly incorrect function of the servo control for travelling foreward.
E 253Broken wire in the load circuit to regulation solenoid valve Yr1A5
E 254
Possibly incorrect function of the servo control for lifting boom.
Short circuit to ground or to +24V in the load circuit Yr1-A5Check, if necessary repair the regulation solenoid valve Yr1A5 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-B5Check, if necessary repair the regulation solenoid valve Yr1B5 and its connecting circuit
E 255Broken wire in the load circuit to regulation solenoid valve Yr1B5
E 256Possibly incorrect function of the servo control for travelling right backw. (R964 C) or bucket tilting out (R974 C).
E 257Broken wire in the load circuit to regulation solenoid valve Yr1A6
E 258Possibly incorrect function of the servo control for travelling right foreward (R964 C) or bucket tilting in (R974 C).
Short circuit to ground or to +24V in the load circuit Yr1-A6Check, if necessary repair the regulation solenoid valve Yr1A6 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-B6Check, if necessary repair the regulation solenoid valve Yr1B6 and its connecting circuit
E 259Broken wire in load circuit to regulation solenoid valve Yr1B6
E 260Possibly incorrect function of the servo control for travelling right backw. (R974 C) or bucket tilting out (R964 C).
E 261Broken wire in load circuit to regulation solenoid valve Yr1A7
Short circuit to ground or to +24V in the load circuit Yr1-A7Check, if necessary repair the regulation solenoid valve Yr1A7 and its connecting circuit
E 262Possibly incorrect function of the servo control for travelling right foreward (R974 C) or bucket tilting in (R964 C).
E 263Broken wire in load circuit to regulation solenoid valve Yr1B7
E 264
Possibly incorrect function of the servo control for retracting stick (only R974C)
Short circuit to ground or to +24V in the load circuit Yr1-B7Check, if necessary repair the regulation solenoid valve Yr1B7 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr1-A8Check, if necessary repair the regulation solenoid valve Yr1A8 and its connecting circuit
E 265Broken wire in load circuit to regulation solenoid valve Yr1A8
E 266
Possibly incorrect function of the servo control for extending stick (only R974C)
E 267Broken wire in load circuit to regulation solenoid valve Yr1B8
E252 to E267
Simultan eously
E 268
No or incorrect function of the servo control
Short circuit to ground or to +24V in the load circuit Yr1-B8Check, if necessary repair the regulation solenoid valve Yr1B8 and its connecting circuit
Missing 24V supply of the servo control plate U48-1/A , connector X840-1
Check 24V supply circuit, r(epair as necessary (Fuse F151, connector X840-1, .)
Possibly incorrect function of the servo control for shovel flap opening. (only R964C)
E 269Broken wire in load circuit to regulation solenoid valve Yr2A2
E 270
Possibly incorrect function of the servo control for shovel flap closing (only R964C)
Short circuit to ground or to +24V in the load circuit Yr2-A2Check, if necessary repair the regulation solenoid valve Yr2A2 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr2-B2Check, if necessary repair the regulation solenoid valve Yr2B2 and its connecting circuit
E 271Broken wire in load circuit to regulation solenoid valve Yr2B2
E 272Possibly incorrect function of the servo control for shovel stick retraction (R964C) or shovel flap opening (R974C)
E 273Broken wire in load circuit to regulation solenoid valve Yr2A1
E 274Possibly incorrect function of the servo control for shovel stick extension (R964C) or shovel flap closing (R974C)
Short circuit to ground or to +24V in the load circuit Yr2-A1Check, if necessary repair the regulation solenoid valve Yr2A1 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr2-B1Check, if necessary repair the regulation solenoid valve Yr2B1 and its connecting circuit
E 275Broken wire in load circuit to regulation solenoid valve Yr2B1
E 276
Possibly incorrect function of the servo control for extension of additional cylinder
E 277Broken wire in load circuit to regulation solenoid valve Yr3B1
E 278
Possibly incorrect function of the servo control for retraction of additional cylinder
Short circuit to ground or to +24V in the load circuit Yr3-B1Check, if necessary repair the regulation solenoid valve Yr3B1 and its connecting circuit
Short circuit to ground or to +24V in the load circuit Yr3-A1Check, if necessary repair the regulation solenoid valve Yr3A1 and its connecting circuit
E 279Broken wire in load circuit to regulation solenoid valve Yr3A1
E 280
Possibly incorrect function of the servo control for swing left
E 281Broken wire in load circuit to regulation solenoid valve Yr150
Short circuit to ground or to +24V in the load circuit Yr150Check, if necessary repair the regulation solenoid valve Yr150 and its connecting circuit
E 282
Possibly incorrect function of the servo control for swing right
E 283Broken wire in load circuit to regulation solenoid valve Yr151
E 268 to E 283 Simultan eously
E 284
No or incorrect function of the servo control
Short circuit to ground or to +24V in the load circuit Yr151Check, if necessary repair the regulation solenoid valve Yr151 and its connecting circuit
Missing 24V supply of the servo control plate U48-2/A , connector X850-3
Check 24V supply circuit, r(epair as necessary (Fuse F152, connector X850-3, .)
Possibly incorrect function of the servo control for pressureless lowering
E 285Broken wire in load circuit to regulation solenoid valve Yr401
E286, 88, 90, to E298
E287, 89, 91, to E299
E284 to E299 Simultan eously
Possibly incorrect function of the servo control for additional movement
No or incorrect function of the servo control
Short circuit to ground or to +24V in the load circuit Yr401Check, if necessary repair the regulation solenoid valve Yr401 and its connecting circuit
Short circuit to ground or to +24V in the load circuit
Broken wire in load circuit to regulation solenoid valve
Missing 24V supply of the servo control plate U48-2/A , connector X850-1
Check, if necessary repair the regulation solenoid valve for additional movement and its connecting circuit
Check 24V supply circuit, r(epair as necessary (Fuse F152, connector X850-1, .)
E 302No entry possible using keypadNo coding plugConsult LIEBHERR customer service.
E 303Diesel engine speed cannot be adjusted using keypad, hydraulic power is reduced.
E 305Malfunctions, eg. swing gear brake, servo control
No CAN bus connection between keypad and BST plate (message also appears if bus arbiter not operating, eg. if no power supply is present).
No CAN bus connection between keypad and ESP01 board (message also appears if ESP01 not operating).
E 307No CAN bus connection between keypad and engine control system PLD
Switch to emergency control speed adjustment S71 and S72 and emergency operation work pumps Y50, consult LIEBHERR customer service.
Switch to emergency switching of servo pressure circuits S73, consult LIEBHERR customer service.
Switch to emergency control speed adjustment S71 and S72 and emergency operation work pumps Y50, consult LIEBHERR customer service.
E 308No display or incorrect display on screen No connection keypad / screen or keypad not operating Consult LIEBHERR customer service.
E 309No Software compatibility between screen and keypad
E 310For boring excavators, Hardware coding and software coding are not in concordance.
Consult LIEBHERR customer service.