1 minute read

ELECTRICAL SYSTEM SISTEMA ELÉCTRICO [1] STARTER / ARRANCADOR

Checking

Motor Test

1. Disconnect the connecting lead from the “C” terminal of the starter and connect a jumper lead from the connecting lead to the positive battery terminal.

2. Connect a jumper lead momentarily between the starter body and the negative battery terminal.

3. If the motor does not run, check the motor

Control

Prueba del motor

C057F067

1. Desconectar el conductor de conexión desde la terminal “C” del arrancador y conectar un conductor puente desde el conductor de conexión a la terminal positiva de la batería.

2. Conectar un conductor puente momentáneamente entre el cuerpo del arrancador y la terminal negativa de la batería.

3. Si el motor no funciona, revisar el motor

Magnet Switch

1. Connect jumper leads from the negative terminal of 6V battery to the body and “C” terminal of magnet switch.

2. The plunger should be attracted, when a jumper lead is connected between the positive terminal of battery to the lead of the magnet switch.

3. The attracted plunger should stay attracted without the jumper from the negative terminal to the “C” terminal.

Llave magneto

0104P109

1. Conectar el conductor puente desde la terminal negativa de la batería 6V al cuerpo y a la terminal “C” de la llave magneto.

2. El vástago debe ser atraído, cuando un conductor puente es conectado entre la terminal positiva de la batería y el conductor de la llave magneto.

3. El vástago atraído debería permanecer así sin el puente, desde la terminal negativa a la terminal “C”.

This article is from: