1 minute read

1.5.2 Error messages appearing after shutdown by the Working Range Limiter . . . 2

1.5.2 Error messages appearing after shutdown by the Working Range Limiter

After shutdown by the Working Range Limiter, the Information display shows one of the following error messages.

Error message Cause Remedy

9.05.1 Maximum overall height exceeded – Retract or extend the main boom – Lower the lattice extension (additional equipment)

9.07.1 Maximum working radius exceeded

9.07.2 Slewing range exceeded

9.07.3 Shutdown area of a monitored object reached – Raise or retract the main boom – Raise the lattice extension (additional equipment)

–Slew to the right (when reaching slewing angle A) –Slew to the left (when reaching slewing angle B) Move to a permissible operating area

Error causes and effects

For further information about Error messages about power units; à Operating instructions GMK 5100, chapter Malfunctions on the superstructure, paragraph Crane control error messages.

Defective part or area Number code in the third line on the display Cause of error Effect / Remedy

Slewing gear service brake IN2301 0 0 0 0 0 0 0 1 Line breakage / earth contact

0 0 0 0 0 0 1 0 24 V short Inform GROVE Customer Support

Blank page