1 minute read
Electrical Control System
from Gehl AL550 Mustang AL508 Manitou MLA 5-60 Articulated Loader Service Manual 50940658 - PDF DOWNLOAD
Table 41: CAN System Inputs Screen ItemInput/OutputDescriptionStatusCondition
•ON/OFF digital electrical Aux Detent SW signal (5VDC ON/ OFF) from joystick trigger toggle switch to MCU. NOTE: self-canceling switch; subsequent pressings toggles ON/OFF.
Advertisement
Aux Detent SW
•When toggled ON, CAN “Aux Detent SW” messages output from MCU to display.
•When toggled ON, analog output signal (12VDC ON/ OFF) from MCU to auxiliary hydraulics valve.
Auxiliary hydraulics detent lock ON/OFF status; if ON (green), current auxiliary flow is maintained without operator input (Aux Hyd Forward/ Reverse Output analog signal 0-12VDC).
Green
•Auxiliary hydraulics detent trigger button (on joystick) is closed (PRESSED); aux. detent flow lock is ON.
•GREEN “Aux Flow Active” on OUTPUTS screen.
•Either GREEN “Aux Hyd Fwd. Out” or “Aux Hyd Rev. Out” on OUTPUTS screen.
Blank
Auxiliary hydraulics detent trigger button (on joystick) is open (NOT PRESSED); aux. detent flow lock is OFF.
High/Lower Speed SW
•ON/OFF digital electrical High Speed SW signal (12VDC ON/OFF) from joystick trigger toggle switch to MCU. NOTE: selfcanceling switch; subsequent pressings toggles ON/OFF.
•When ON, CAN “High/Low Speed SW” message output from MCU to display.
•When ON, digital electrical output signal (12VDC ON/ OFF) from MCU to TCU.
•ON/OFF low beams digital electrical signal (12VDC ON/ OFF) from control lever switch to MCU.
High/Low speed mode select status. If ON (green), high speed travel mode is enabled. If OFF (blank), low speed travel mode is enabled.
NOTE: Pressing and holding high/low speed button on joystick for 0.5 seconds toggles high/low speed ON/ OFF; rabbit (High/ON) or turtle (Low/OFF) displayed on display.
Green
High/Low speed mode select button (on joystick) is closed (Toggled to High Speed).
Blank
High/Low speed mode select button (on joystick) is open (Toggled to Low Speed).
Green
•Control lever in the low beam road lights ON position.
Low Beams SW
•CAN “Low Beams SW” message output from MCU to display.
•ON/OFF digital electrical signal (12VDC ON/OFF) from MCU to low beam lights.
Road lights switch (on control lever) low beam road lights position status (control lever BACK).
Blank
•Low beam road lights activated.
•Control lever NOT in the low beam road lights ON position.
•Low beam road lights deactivated.