Claas QUANTUM 6800 SQUANTUM5500 S-18QUANTUM 5500S-16QUANTUM 5500 S QUANTUM 4500 S Operator’s Manual

Page 39

Assembly Install the top plate (68) with rod (82) on the front plate and fasten on both sides with washer (83) and split pin (81).

QUANTUM 5500 S-16 / 5500 S / 4500 S from serial no. 614 0 02243

68

(Fig. 25) 81

83 82 25

73073

Install fill indicators (88) (reed contacts) on bracket (69) with two screws each.

QUANTUM 5500 S-16 / 5500 S / 4500 S from serial no. 614 0 02243

68

84

69

ON OFF

ATTENTION! Look out for pinch and crush points when laying out the wiring.

84 ON

89

– Lay out wiring so it cannot be pinched or crushed during operation.

OFF

88 86

87

85 26

73074

Install wiring (84) through the cross member of the top plate (68) on the right side. Connect wires (ON-ON; OFF-OFF). The top reed contact is connected to the “ON” connection. Fasten wiring with self-locking straps. Insert the strap (87) with the sensor magnet through the guides of the bracket (69). Fasten strap (87) and top plate (68) with the pins (89) to the bracket (69). Secure pins (89) with washer (86) and roll pin (85). (Fig. 26)

Wind tension ropes (92) around the hoop (73) at the rear.

QUANTUM 5500 S-16 / 5500 S / 4500 S from serial no. 614 0 02243

70

91

73

Run tension rope from the top through the eyelet (91) on the bracket (70).

90 92

Attach tension rope at front to the hook (90) on the bracket (69). (Fig. 27)

69

73083

27

0299 615.8 - BA QUANTUM 6800 S / 5500 S-18 / 5500 S-16 / 5500 S / 4500 S