Every 10 hours

Next Article
Every 100 hours

Every 100 hours

1. INNER TRACK FRAME SUPPORTS -

Lubrication Inject grease in the two linkage fittings (one on either track frame.) Before injecting grease, accurately clean fittings. 2. CAB VENTILATION AIR FILTER - Check For access to this filter, open the rear door on the left side of the machine. Release the retainers on the filter housing Remove frame C and pull-out filter F.

WARNING

Wear safety glasses with side shields or goggles when using compressed air for cleaning to reduce the danger of personal injury from flying particles. Limit the pressure to 2 bar according to local or national requirements.

Inspect filter: if restricted clean as follows: - tap filter delicately, with holes lowermost, on a flat hard surface; - using dry and clean compressed air, blow through filter in a direction opposite the arrows stamped on back. Move air jet up and down the pleats until dust is completely removed; - re-fit filter in the direction of the stamped arrows showing the inlet air path.

Important – Keep air jet sufficiently clear of filter element, to avoid damaging it.

Note – Before fitting back the filter, clean container accurately.

Study SAFETY RULES in the front of this manual thoroughly for the protection of machine and safety of personnel