Value Proposition:
The HF1200 and HFT1200 regulators offer high flow capability with an inlet pressure up to 1,250 psig. The large convoluted Hastelloy C22® diaphragm provides stable pressure control over the operational range of the regulator.
The combined high flow and high inlet pressure increases the application range of the regulator thus reducing regulator inventories.
The HFT1200’s tied diaphragm provides positive shut off for hazardous gas applications.
Veri flo Contact Information: Parker Hannifin Corporation Veriflo Division 250 Canal Blvd Richmond, California 94804 phone 510 235 9590 fax 510 232 7396 veriflo.sales@parker.com www.parker.com/veriflo Mobile App: m.parker.com/veriflo
UHP Single Stage, Pressure Regulator High Flow, Welded, Stainless Steel HF1200W & HFT1200W Series Product Features: • Seat
media
•
competitive
•
• Standard
•
•
•
material selection for
compatibility
59% greater effective diaphragm area over
products
HFT offers Hastelloy trim for corrosive applications
full internal electropolish
High inlet pressure with 1.2 Cv to meet a variety of applications
Hastelloy C-22® diaphragm for high corrosion resistance
HFT offers a tied diaphragm for positive shut off • Large convoluted diaphragm provides stable pressure control
HF1200 Regulator with 3/4” tube fittings
Inlet Pressure: 50 psig, N2 Outlet Pressure: 30 psig
HF1201 Regulator with 3/4” tube fittings
Inlet Pressure: 100 psig, N2 Outlet Pressure: 50 psig
HF1202 Regulator with 3/4” tube fittings
Inlet Pressure: 120 psig, N2 Outlet Pressure: 100 psig
HFT1200 Regulator with 1/2” Face Seal Connections
Inlet Pressure: 50 psig, N2 Outlet Pressure: 30 psig
HFT1201
with 1/2” Face Seal Connections
psig,
HFT1202 Regulator with 1/2” Face Seal Connections
Inlet Pressure: 600 psig, N2 Outlet Pressure: 150 psig
50.0 0 Flow
100200300400 600 500 700 06/08/2007 Flow Media = N2 Test Performed By: J. Isaacs
tube fittings
0 10 20 30 40 50 0 Flow(lpm) Outlet Press u re (p si g)
100 200 300 400 600 500 06/08/2007 Flow Media = N Test Performed By: J. Isaacs
tube fittings
psig 5 15 25 35 45 55 65 75 85 95 0 Flow(lpm) Outlet Press u re (p si g)
200400600800 1200
06/08/2007 Flow Media = N2 Test Performed By:
0 20 40 60 80 100 0
Outlet Press u re (p si g)
200400600800 1200
Safety Guide and Installation and Operating Instructions available at www.parker.com/veriflo HF1200W & HFT1200W Series Flow Curves 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
(lpm) Outlet Pressure (psig) HFT1200 Regulator with 1/2" Face Seal Connections Inlet Pressure: 50 psig, N2 Outlet Pressure: 30 psig Date: 9/16/2008
HR1200-1 Regulator with 3/4"
Inlet Pressures: 50 psig, N2 Outlet Pressures: 30 psig
Date:08/24/07
HR1200-2 Regulator with 3/4"
Inlet Pressures: 100 psig, N2 Outlet Pressures: 50
Date: 8/24/07
1000 1400
J. Isaacs HR1200-2 Regulator with 3/4" tube fittings Inlet Pressures: 120 psig, N2 Outlet Pressures: 100 psig
Flow(lpm)
Date: 8/24/07
1000 1400
0.0 20.0 40.0 60.0 80.0 100.0 120.0
0 Flow
Face Seal
Date:
200400600800 1200 1000 14001600 50
40 30 20 10 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 0 1400 95
65 55 45 15 5 25 35 75 85
100 Outlet
80 60 40 20 0 200 400 600 800 1000 1200 0 1400
200 400 600 800 1000 1200 0 1400
1600
120 100 80 20 0 40 60 140 160 200 400 600 800 1000 1200
1400
1600 100
80 60 40 20 0 120 0 100 200 300 400 500
50
35 30 25 10 5 15 20 40 45 700 Additional
Regulator
Inlet Pressure: 120
N2 Outlet Pressure: 100 psig 0.0 20.0 40.0 60.0 80.0 100.0 120.0 0 Flow (lpm) Outlet Press u re (psig) HFT1201 Regulator with 1/2" Face Seal Connections Inlet Pressure: 120 psig, N2 Outlet Pressure: 100 psig Date: 9/16/2008 200400600800 1200 1000 14001600
140.0 160.0
(lpm) Outlet Pressure (psig) HFT1202 Regulator with 1/2"
Connections Inlet Pressure: 600 psig, N2 Outlet Pressure: 150 psig
9/16/2008
Outlet Pressure(psig) Flow(lpm)
Outlet Pressure(psig)
Flow(lpm)
Pressure(psig)
Flow(lpm)
Flow(lpm)
Outlet Pressure(psig)
0
Flow(lpm)
Outlet Pressure(psig)
600 0
Outlet Pressure(psig)
flow curves available upon request
HF1200W & HFT1200W Series Dimensional Drawing Ordering Information Basic Series HF12 (Non-Tied Diaphragm) HFT12 (Tied Diaphragm) Pressure Ranges Range 3P Outlet Gauge 00 = 5 - 50 psig 01 = 5 - 100 psig 01 15 = 5 - 150 psig 2 02 = 20 - 200 psig 2 Body Material W = Welded 316L Stainless Steel Seat Material K = PCTFE V = Vespel® Porting 2P = 2 Ports No X required for gauges, Inlet & outlet ports only 3P = 3 Ports One X for gauge port 4P = 4 Ports Two X for gauge port 4PB = 4 Ports One X for gauge port See Regulator Porting Guide for additional options and port layouts Outlet Gauge VX = -30 in Hg 0 - 150 psig - HFT1200 only. OL = 0 - 60 psig 01 = 0 - 100 psig 2 = 0 - 200 psig X = No Gauge Additional ranges available upon request Inlet Gauge 20 = 0 - 2000 psig X = No Gauge Additional ranges available upon request Port Style 8T = 1/2” A-LOK® 12T = 3/4” A-LOK® FS8 = 1/2” Face Seal FS12 = 3/4” Face Seal TS8 = 1/2” Tube Stub TS12 = 3/4” Tube Stub Port Configuration M = Male F = Female I = Internal Face Seal 1/4” FS-M Gauge Ports are Standard 1 2 3 5 6 7 8 1 2 3 4 5 6 7 HFT12 00 W K 3P OL FS8 FMF HFT1200WK3POLFS8FMF Sample: Finished Order: 8 4 Build a HF1200W or HFT1200W Series regulator by replacing the numbered symbols with an option from the corresponding tables below. Color Explanations: 9 9 For an explanation of Ordering options please reference literature 25000275 at www.parker.com/veriflo Black = Standard Lead Time Configurations Blue = Extended Lead Time Configurations
Materials of Construction
Wetted
Body 316L Stainless Steel Diaphragm Hastelloy C-22®
Poppet 316L Stainless Steel
Poppet Spring 316L Stainless Steel Seat Retainer 316L Stainless Steel Seat Options PCTFE (std) or Vespel® Non-wetted Cap Nickel Plated Brass Nut 17 - 4 PH Knob ABS (Black)
Operating Conditions
Maximum Inlet 1,250 psig (86 barg)
Outlet Options 5 -50 psig (3 barg) 5 -100 psig (7 barg) 5 -150 psig (10 barg) 20 - 200 psig (14 barg)
Temperature
PCTFE -40°F to 150°F (-40°C to 66°C)
For additional information on materials of construction, functional performance and operating conditions, please contact factory.
Functional Performance Design
Burst Pressure 3,750 psig (259 barg)
Proof Pressure 1,875 psig (129 barg) Flow Capacity Cv 1.2 Leak Rate
Internal Bubble Tight at 70 psig minimum External < 1 x 10-9 scc/sec He Inboard Test Method Supply Pressure Effect 5.4 psig / 100 psig
Approx. Weight 4.2 lbs. (1.9 kg) Surface Finish 10 micro inches Ra
Vespel® is a registered trademark of DuPont Performance Elastomers L.L.C. Hastelloy C-22® is a registered trademark of Haynes International, Inc. A-LOK® is a registered trademark of Parker Hannifin Corporation
OFFER OF SALE:
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” elsewhere in this document or available at www.parker.com/veriflo WARNING USER RESPONSIBILITY
!
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. THIS DOCUMENT IS FOR REFERENCE ONLY. PLEASE CONSULT FACTORY FOR LATEST PRODUCT DRAWINGS AND SPECIFICATIONS
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing are subject to change by Parker Hannifin Corp and it’s subsidiaries at any time without notice.
Proposition 65 Warning: This product contains chemicals known to the state of California to cause cancer or birth defects or other reproductive harm.
Use mobile device to scan this QR Code.