BOQ ESTIMATES

Page 1

SUMMARY OF ESTIMATES

NB:ALLWORKSSHALLBECARRIEDOUTASPER ARCHITECT'SSPECIFICATIONS ALLWORKSSHALLBECARRIEDOUTASPERAPPROVEDDRAWINGSONLY

1
Zahra-Bagasrawala PublicSchool Sr.No. DescriptionofItem Amount(Rs.) Contingencies@10% 3,981,755.51 GrandTotal 43,799,310.59 1 SitePreparationandCleaning 25,00000 2 CivilWork 31,192,190.08 3 CarpentryandBuiltinFurniture4 MiscellaneousItems 5,00000 5 Electrical 6,768,000.00 6 Plumbing 1,827,36500 7 LandscapingandGardeningTOTAL 39,817,555.08

BILL OF QUANTITIES

ForallItemsinallSections:Rateshallincludetransportation,loading/unloading,providing/supplying/laying/fixing/installing/ fabricating/testing/commissioningetc onsite RateshallalsoincludealltaxessuchasVAT,excise,salestax,octroi,etc

SECTION-I: SitePreparation&Cleaning

Cleaningandclearingthesiteofallrocks,boulders,brick-bats,stone,bushes, shrubs,etccomplete,asdirectedbythearchitectforstartofconstructionactivity

Note:

1)TheitemsgivenbelowshallbeasperSectionA""Earthwork,MetalPacking& SubsurfaceDrainage"ofthespecifications

2)Rateforexcavationshallincludedewateringduringtheexcavationincluding shoring,struttingetcandkeepingitdryduringexcavationandconstruction

3)AllearthworkshallbecarriedoutasperConservationArchitect'sinstructions andsafetynormsasperrelevantIScode Therateshallincludeallscaffolding andmeasuresforcordoningoffareasduringdismantling,providingsignboards etc

4)Alldebrisandscrapmaterialsfromearthworkshallbecontractorspropertyother thanthatwhichisreusedforback-fillingetc andthisdebrisandscrapmaterials shallberemovedawayfromsiteimmediatelyonhisown Thecontractortogive rebateinratesagainstmaterialsandscrap/debrisfromsuchdismantledwork whichshallbecontractor'sproperty

5)Forallearthworkitems,thecontractorshouldcarefullystackallexcavated materialatsiteaspertheinstructionsoftheArchitect Alldebrisassociatedwith theearthworkshouldhoweverbedisposedoffbytheContractor

6)Themeasurementofexcavationshallbetakenincum asperrectangular trenchofbottomwidthofconcretemultipliedbyverticaldepthoffoundationfrom groundeventhoughcontractormighthaveexcavatedwithslopingside/fulllength trenchforhisconviency

Surfaceexcavationandexcavationforretainingwalls,basement,watertanks, effluenttreatmenttanks,etc includingbackfillingofapprovedexcavatedmaterials infoundations, &behindretainingwallsaftercompletionofwaterproofingetc wateringandconsolidating,cartingawaysurplusearth, includingpreparingthe surface (Note:Allbackfilling&spreadingofearthshallbecarriedoutinlayersnot exceeding200mmandcompactedto90%ordinaryproctordrydensity)

Fillinginplinthandinotherplaceswithapprovedmurumbroughtfromoutside, includingwateringconsolidatinginlayersnotexceeding200mmby8-10tonnes roadrollerorotherapprovedmechanicalequipmentetc

Anti-termitePreconstructionTreatment:(AsperIS:6313Part-III)(Note: Anti-termitetreatmentshallbecarriedoutthroughspecialisedagencyreputedin PestControltreatmentandapprovedbytheArchitect Thecontractortogive10

Providingpost-constructionalanti-termitetreatmentbydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor

Providingpost-constructionalanti-termitetreatmentbydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor termites,borers,wetrotsanddryrots

Providing,chasing,inserting/layingDampproofcourse50mmthickM-20cement concretelayerandbitumenusingcementwithapprovedwaterproofingcompound

Note: 1)TheitemsgivenbelowshallbeasperSectionB"Concrete-Plain&Reinforced" ofthespecifications

1
Sr No Description Qty Unit Rate(Rs) Amount (Rs)
461090 Cum 286 13187174
completeasdirected 408590 Cum 780 3187002
yearsguaranteeonasuitablebond) 228960 Sqm 195 446472
termites borers wetrotsanddryrots Coveredfloorareashallbemeasuredfor payment (GroundFloor) 83130 Sqm 195 1621035
Coveredfloorareashallbemeasuredfor payment (FirstFloor) 30510 Sqm 195 594945
attherateof1Kgper50kgofcementetc complete 77940 Sqm 364 2837016 5457491
TOTALOFSECTION-I
CIVILWORK a1 A EARTHWORKANDMETALPACKING a1 a2 a3 a4 a5 a6 TOTALOFSUBSECTION-A B CONCRETE-PLAIN&REINFORCED LUMPSUM 25000 250000
SECTION-II:

BILL OF QUANTITIES

2)ForsmallconcreteonapprovalofConservationArchitect,weighbatched concreteasperdesignmix,inmanuallyormechanicaltypeoperatedweigh batcherdialtypeormechanicaltypeofminimumcapacity650Kgsshallbeused Weighbatchershallbecalibratedregularly

3)Forallmajorconcretepours,Contractorshallusereadymixedconcrete(RMC) ofUnitechPrefabLtd orM/s Larsen&ToubroLtd approvedAgencies Only53 gradecementshallbeusedinRMC Aggregatepropertiesandgradingdesign mix quantityofsuperplasticiser settingtime amountofslumpatthepouringsite shallbegotapprovedbeforeitsuseineachmajorconcreting

4)Concretemixproportionwillbebasedon50kg weightofcementbags deliveredatthemixer

5)TheContractorisentirelyresponsibleforthedesignofconcretemixes The designishowever,tobeapprovedbytheArchitect

6)ConcreteM-20/20meansconcretemixM-20gradeusingmaximumsizeof coarseaggregates20mm

7)Shuttering,formwork,centeringshallnotbepaidseparatelyandshallconform toSection-C

8)Curingcompoundmaybepermittedonlyforinaccessiblelocations

9)OnlyRiverSandshouldbeused Washingofsandinrotaryscrewtypewashing machinesisamust

10)RatesshallbeinclusiveofcostofSuperplasticiserofapprovedqualityandof approveddosage

11)Ratesshallbeinclusiveofprovidingpockets,holes,inserts,pipes,etc

12)Mechanicalvibrators,internaland/orexternaltobeused

13)AlldefectiveconcreteifapprovedbyArchitect,shallberepairedbythe contractorathisowncost,usingapprovedepoxymortarorPolymermodified mortarasperManufacturer'sspecifications

14)Therateshallincludethecostofapplying2coatsofpolymerbondingagenton allsurfaceofoldornewconcreteatconstructionjointpriortoconcretingagainst thesame

15)Useoffinesandwithpropergradingisamust

16)Screeningofmetal-IandIIforremovingexcessiveflakyunderandoversize material,stonedustetc isamust

17)Onlyapprovedmouldreleasingagentshouldbeused

18)Cleaningofshutteringplatesbymechanicalbuffingaftereveryuseisamust

19)Allconcretesurfacesshallbeformfinished

20)Whereplasteringisspecified,concretesurfacesarerequiredtobehacked immediatelyaftertheremovalofformworkasdirectedbytheArchitectwherever required Additionalrateshallnotbepaidtocontractorforhacking

21)Contractorshouldmakearrangementfortablevibratorforcastingthecover blocksofrequiredsizeandgrade

22)Rateshallbeinclusiveofprovidingcoverblocks Coverblocksshallbemade ofthesamegradeofconcreteofstructuralmemberinwhichtheblocksaretobe used

23)Alljointsinshutteringshallbesealedbyuseof5mmthickcompressible materialgasketsandfixingagent

24)Constructionjointshallbeminimuminnumbersandtheirlocationshallbe approvedbytheConsultant Constructionjointsshallbetreatedproperlywith bondingcoatofapprovedmaterialtobeappliedattheoldconcretebefore commencingthefreshconcretingoperations

25)Informfinishsurfacesthepatternstobeprovidedfortheformworkshallbeas perarchitectssuggestions

26)Allsack-rubbedsurfaceshallbesackrubbedwithwhitecementofsuggested proportionasperArchitectsapproval

27)Allconcealeditemslikeconduits,junctionboxes,fixturesetc shallbelocated asperdetailsandlocationstobeapprovedbeforecasting

NotesforFormwork:

Note:1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications

2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping

3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework

4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed

5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorathiscost

6)Ratesquotedshallbeinclusiveofallformworkatalllevels

7)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates

8)Onlyapprovedmouldreleaseagentshouldbeused

9)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust

10)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork

11)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect

2
Sr No Description Qty Unit Rate(Rs) Amount (Rs)

BILL OF QUANTITIES

12)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately

13)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect

14)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection

15)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant

ProvidingandlayingConcreteM20/40usingRMCforallPCCworksbelowraft slab,plinthbeams,foundations,etc includingsideformsifrequired Therateshall beinclusiveofalltaxes,towardsplants&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,centering,formwork, compacting rougheningthesurfaceifspecialfinishistobeprovidedandcuring

ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc

Providing&layingM30/20,usingRMCforRCCincludingpumpingforfoundation, pilecaps,raftslab,column,walls,shearwalls,boxcolumn,retainingwalls,plinth beams,floorbeams,invertedbeams,slabs,staircase,droppardis,chajja, parapets,pergolas,trenchslabandbeamsinstructuralfloors,loftslabsatall levels lintelbeams/verticalstiffenersetcincludingRCCundergroundwatertanks septictanks,effluenttreatmenttanks,overheadwatertanksetccomplete Therate shallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads&lifts, allfloorsallchargesrequiredincludingtransportation,shuttering,centering, formworkasperconditionsbelowetc

ProvidingandlayingconcreteM25/20usingRMCforstaircaseongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow,

ProvidingandlayingCC M25/15inbrickjali-precastorcastinsituusinggraded aggregatesandnominalreinforcement6mm,asperdesign&sizeapprovedby theConsultant Theconcretetobemachinemixedandtoincludeallnecessary shutteringofwaterproofplyandadequatestrutting&scaffolding,andadequate curing,etc

Providing&layingConcreteM20/40,usingRMC,inalternatebaysfor75MM plinthprotectionandpavingincludingcompacting,vibrating,curing,finishingto correctline&levelwiththeuseofwoodenbottomandsurfacefinallyfinishedwith broomsasdirectedbyArchitect Jointsofandasprovidedinalternatebaysshall befilledwithbitumenetc allcompletetothesatisfactiontotheArchitect

ProvidingandconstructingRCCundergroundwatertankincludingexcavationinall typesofsoil,refillinginsidesoftank,trimming,dressing,leveling,stackingand disposalofsurplussoilandincluding:

i)Rubblesoling230thk

ii)PCC,M20/30belowraft

iii)M-25/20RCCworkinraftslabs,sumpbase,beams,RCCwalls,columns,top slabsetc includingunwrotshutteringtoRCwallsatalllevels

iv)TMTreinforcement

v)Waterproofcementplastertoinsideofwatertanks

vi)BoxtypewaterproofingtreatmentforraftandwallsofUGtank

vii)Patentedcementbasedwaterproofingtreatmenttotopofslabs

viii)50mm thk IPStoraftslab

ix)Providingandfixingcastironmanholecovers2nos 600mmdia withlocking arrangements

x)PVCwaterstop150mmdia;embeddedintakeandoutletpipesetc

UGtankcapacity

Providing,erecting,fixingandcommissioningSintexorapprovedequivalent doublelayeredtanksonoverheadelevatedpedestalasdirectedincluding scaffoldingallalliedplumbing,valves,stopcocks,MCGMcertifiedwatertankcap, includingcleaningetc completeasperthesatisfactionoftheArchitect

Notes:

1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications

3
Sr No Description Qty Unit Rate(Rs) Amount (Rs)
etccomplete 15711 Cum 7800 12254346
complete (FloorSlabs) 21730 Cum 12740
complete 80123 Cum 8450 67703935
etc complete 275 SqMt 8450 2319525
complete 24948 SqMt 900 224532
19485 Runningmt 7800 1519830
1350000 Litres 65 87750
675 Litres 8694 586845
276838926 126782091 b1* b2-4 b5 b6 b7 b8 b9* b10 TOTALOFSUBSECTION-B C FORMWORK

BILL OF QUANTITIES

2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping

3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework

4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed

5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorat hiscost

6)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates

7)Onlyapprovedmouldreleaseagentshouldbeused

8)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust

9)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork

10)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect

11)Providingcutouts holes slits depressionetc forelectricalfixturesshallnotbe paidseparately

12)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect/consultants

13)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel andverticalityoftheshuttering stagingtoachieve requireddegreeofperfection

14)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant

Notes:

1)TheitemsgivenbelowshallbeasperSectionD:'Reinforcement'ofthe specifications

2)CoverblocksshallbeofgoodqualityconcreteM30/10andshallbevibratedon atablevibratortoreducethepermeability

3)Whereverweldingofreinforcementisspecified,thesameshallbecarriedout conformingtoIS:9417orIS:2751 Weldingshallbecarriedoutbyapproved qualifiedweldersonly Onepercenttestingofweldsshallbecarriedforalltypesof welds

4)Overweightofthesteelshallnotbeconsideredforcalculatingconsumptionand paymentpurpose,IS constantforweightofdifferentdia ofbarsshallbe consideredforpaymentaswellasconsumptionpurpose

5)Columnreinforcementbarsarerequiredtobelappedinthemiddleportionof columnsasperIS13920 Properarrangementshallbemadetosupport reinforcementprojectingabovefloorlevel Similarlylapswithinadistanceof2D (depthofbeam)or1/4spanfromthefaceofthecolumnarenotallowed The overhangingbarsshouldbeproperlysupported Thecostoftheseworksis deemedtohavebeenincludedintherate

ProvidingandfixinginpositionmildsteelreinforcementofTATA/Vizag/SailSteel ofvariousdiametersforRCC piles pilecaps footings foundations slabs beams columns,canopies,staircases,dowels,chajjas,lintels,pardis,copings,fins,arches etc asperthedetaileddesigns,drawingsandschedulesincludingcutting, welding,bending,hookingthebars,bindingwithGIwiresandconcretecover blocksetc complete Noseparatepaymentforchairs,laps,wastageandbinding

Supplying,fabricating,erecting,aligninginposition,fixing,StructuralSteel ofTATA /Vizag/SailSteelinalltypesofmembers(Box,Ropes,I-sections,C-sections, L-anglesetc)forColumns,Beams,TrussRafter,Purlinforroofs,lofts,stairs, mezzanines,storageracksforparaffinboxes,portals,braces,underpinning, shoring,frames etc Theratetoincludecutting,anchorfasteners,bolting, welding wastageandapplicationofepoxybasedpaints(Asianmake)asper manufacturer'sspecificationsandasdirected Therateshouldincludepaintingof thesteelasstatediniteme3below

4
Sr No Description Qty. Unit Rate(Rs.) Amount (Rs)
wirewillbemade 147130 78500 11549705 11549705
Squarehollowsection200mmx200mm 480 10400000 499200 D REINFORCEMENT d1* TOTALOFSUBSECTION-D
e1 ThisitemisworkedoutbytheStructuralConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted ThisitemisworkedoutbytheStructuralConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
E STRUCTURALSTEELWORKSANDOTHERFABRICATIONITEMS

BILL OF QUANTITIES

Providing fabricating erectingandfixingatalllevelsstructuralsteelofTATA/ Vizag/SailSteelinalltypesofmembersforColumns,Beams,TrussRafter, Canopies,roofcovers,purlinforroofs,lofts,mezzanines,storageracksforparaffin boxes,portals,braces,underpinning,shoring,frames,workforallstructuraland otherpurposes,includingcuttingedgestotherequiredprofile,bolting,welding, anchorfastening,riveting,groutingetc completeinallrespects,includingepoxy

PaintingofSteelWork

Supplyingpaintingandothermaterialsandlabourrequiredforpaintingofstructural steelasdetailedbelow:

i) Surfacepreparation:

Mechanicalcleaning,removinglooserust/scaleusinghardtools,powertools,use ofaromaticsolventstoremovesoil/greasepresentandtoensureacleananddry surfacebeforepriming

ii) Primer:

SinglecoatofEpoxyresinandzincphosphateoftotaldryfilmthicknessof25 microns

iii) Finish-Coat1:

Singlecoatofhighbuildchlorinatedrubbermediumwithmicaceousironoxideof totaldryfilmthickness of75microns

iv)FinishCoat2&3:

Twocoatsofplasticchlorinatedrubbermediumsuitablypigmentedof25microns dryfilmthickeach TotalDFTofpaintsystemshallnotbelessthan200micron

Providingfabrications,erectingandfixingSS Railing

i)SS PoleMadein16gauge50mm DiameterISapprovedSS304pipewitha ornamentalSSringatthebottomendsSS topatapexforassemblyofupper Handholdpipewholeunitprovidedwithmirrorfinish

Note:

Measurementshallbetakenforcompletelaidroofinsquaremeter Overlapswill notbepaidextra Therateshallincludeallthematerial,labourbolts,nut,washers andtoolsandplantsetc complete

SteelFramedRoofingSystem

ProvidingandfixingofSteelFramedRoofingSystem ExternalSheet:Klippon/ SteellockAZ150SMPcolourcoatedGalvalumein058mmTCTandincluding screwsandclips InternalSheet:Hi-Rib/HispanAZ150BareGalvalume/SMP colourcoatedGalvalumein047mmTCTincludingscrews Insulation:Supply andLayingof50mmthicklogfiberresinbondedfiberglassrollinsulation16kg/m3 densitytobefixedbetweeninternalandexternalsheets SubGirt:G I Purlins40 x50x40mmx16G(16mm)galvanisedsteelfixedtopurlins/girtwithselfdrilling

Providingandfixingofflashingofallsizesforf1above

ThisitemisworkedoutbytheConsultant

Forthepurposeofthiscourseanapproximateamountisbudgeted

Note:

1)Theitemsgivenbelowshallbeasper'MasonryWork'ofthespecifications

2)Rateshouldbeinclusiveofscaffolding curingandalsodewatering&keeping surfacedryduringconstruction

3)CementformanufacturingconcreteblockstobeprovidedbyContractor

4)Onlyselfsupportingscaffoldingwillbeallowed,noholesinmasonrywouldbe permitted

5)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc

6)Factoryincludingblockmakingmachineformanufacturingofconcreteblocks shallbeapprovedby Architect-in-charge

7)Thecementforblockmasonryshallconfirmtotherequirementofminimum cementrequirementforPCC ofconcretespecifications

8)Requiredquantityofconcreteblocksaretobemanufacturedwithgroovesto accommodatetheconduitpipes/waterpipesetc Thegroovesshouldbestaggered onbothsides

9)Therateforconcreteblockmasonrywallsshallbeinclusiveofproducinghalf blocksandoddsizedblockstosuittheconstruction

10)Mortarsforallmasonryworkshallbemixedinanapprovedmortarmixeror concretemixer

5
Sr No Description Qty Unit Rate(Rs) Amount (Rs) e2* e3 e4 TOTALOFSUBSECTION-E F ROOFING f1 f2 TOTALOFSUBSECTION-F G MASONRYWORK
paintingasspecifiedine3 910 10400000 946400
(Foraheightof12M) 163500 50000 817500 24732489
fastenersatmax 500mmcenters 79400 100000 794000
794000

BILL OF QUANTITIES

11)Handmixingofmortarwillnotbeallowed

12)Onlyriversandand43gradecementshallbeused

13)Washingofsandinrotaryscrewtypewashingmachinesisamust

14)Bricksusedshallbeoffirstclassandshallbeofregularinshapeandtheir edgesshouldbesharpandshallbefreefromcrack Brickshallbefullysoakedin cleanwaterbysubmerginginatankforaperiodof12hoursimmediatelybefore use

15)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical telecommunicationandwatersupplyandplumbingetc

Providingandlayingbrick(firstclass)masonrywallin1:6C:M,aboveplinthorat alllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstriking joints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15

Providingandlayingbrick(firstclass)masonrywallin1:6C:M,aboveplinthorat alllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstriking joints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15

Providingandfixingbasalt/Maladstonecopingoverterraceparapethaving dimensions450mmwide100mm thicknessinpiecesof600mmlengthovera

Notes:

1)Theitemsgivenbelowshallbeasper'Plasteringofthespecifications

2)Scaffoldingforplasteringshallbeofselfsupportingtype Holeswillnotbe allowed tobemadeinthemasonryorRCCworkforanchoringthescaffolding

3)OnlyRiverSandshouldbeused Howeverwashingofsandinrotaryscrewtype washingmachinesisamust

4)Mortarforplasteringworkshallbemachinemixedinamortarmixerorconcrete mixer Handmixingofmortarwillnotbeallowed

5)Therateforplasteringshallalsoincludeprovidingandmixing/applyingan approvedbondingagentasperdirectionofArchitect-in-charge,andalsoapplying approvedhack-aidonsurfacereceivingplaster

6)Only43gradecementshallbeused

7)Rateshouldbeinclusiveofscaffoldingandcuringshallbestartedassoonas theplasterhashardenedsufficientlynottobedamagedwhenwatered Theplaster shallbekeptwetforatleast10days

Providing12mmthickInternalcementplasterintwocoatsincementmortar1:4 with/withoutneeru,finished smoothforallRCC/brickblockmasonrywork

Providingsandfaceplasterexternallyintwocoatsusingapprovedscreenedsand inallpositionincludingprovidingbasecoatof15mmthickincementmortar1:4 mixingapprovedwaterproofcompoundattherateof1kg/50kgofcementand curingthesamefornotlessthantwoweeksandkeepingthesurfaceofbasecoat roughtoreceivethesandfacedtreatment8mmthickincementmortar1:4and finishingthesurfacebytakingoutgrainsandcuringfor14daysincludingpreparing

6
Sr No Description Qty Unit Rate(Rs) Amount (Rs)
Bag/cum) (groundfloor) 91302 182000 16616964
Bag/cum) (firstfloor) 39250 182000 714350
mortarbeddingofCM1:6/Limemortar1:3 3360 Providingandfixing inpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3(groundfloor) 471 1274000 5994807 Providingandfixing inpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3(firstfloor) 125 1274000 158613 Providingandfixing inpiecesof600mmlengthoveramortarbeddingof CM1:6/Limemortar1:3(groundfloor) 254 1274000 3237234 Providingandfixing inpiecesof600mmlengthoveramortarbeddingof CM1:6/Limemortar1:3(firstfloor) 076 1274000 966966
includingcuring,andscaffoldingetccomplete 289036 39000 11272404
surface wateringandscaffoldingetc complete 88008 78000 6864624 Providing&applyingacontinuouscementplasterdripmouldofsize50mmwide and15mmthickunderRCCpardi chajjaandaroundwindowopeningsatalllevels includingnecessaryscaffolding,stagingetc andcuringcomplete 4360 20000 8720 18224228 249389777 g1 g2 g3 g4 RCCLintels g5 RCCLintels g6 RCCSill g6 RCCSill TOTALOFSUBSECTION-G H PLASTERING,POINTING h1* h2 h3 TOTALOFSUBSECTION-H J PAINTING

BILL OF QUANTITIES

Notes:

1)Theitemsgivenbelowshallbeasper'Paintingofthespecifications

2)ScaffoldingforPaintingshallbeofselfsupportingtype Holeswillnotbe allowed,tobemadeinthemasonryorRCCworkforanchoringthescaffolding

3)ThebrandsofthePaintshallbespecifiedandreadymadepaintofrequired shadeshouldbeused

4)Thesurfaceshallbemadeperfectlysmoothbyrubbingwithsandpaperof differentgrades

5)Allholesandopenjointsshouldbefilledwithstrongputtyorwithamixtureof glueandplasterofparisandsmoothenedbyrubbingwithsandpaper

6)Insteelwork,allscales,dirt,suppliersdeliverymark,oil,greaseetcshallbe removedwithsandpaperbeforepainting Specialcareshallbetakenforcleaning thecorners

7)Eachcoatsshallbeallowedtodryupperfectlybeforethesucceedingcoatis laidoverit

8)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction

Providingandapplying3coatsoveracoatofprimer,ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces,scaffoldingetc

Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces,

Notes:

1)Theitemsgivenbelowshallbeasper'Flooring'ofthespecifications

2)Atleast6samplesforallfinishingitemsofwork,fromdifferentapproved sourcesshallbesubmittedbeforestartingtheworkforapproval Architectin chargedecisionregardingtheshade,qualityandthesourceisfinal Alllike materialsofflooring,cladding,etctobefromsamebatchasperapprovedsample

3)Rateshallbeinclusiveofallexposedstone/tileedgestobechamfered,hand polishedandmouldedasdirected

4)Ratesforverticalcladdinginstoneofthicknessfrom6mmto25mmshallinclude exposedrightangularcornerjointsfinishedandedgespolishedandmouldedas perArchitect'sinstruction,withcutting6mmgroovesandalsoedgepreparationto suitcornerangles

5)Skirting/dado/cladding,becauseofvaryingheightwillbemeasuredandpaidon squaremetrebasisinsteadofonrunningmetrebasis

6)Therateforflooring/claddingshouldbeinclusiveofbedding/backcoatas specified Thethicknessofmortarbeddingorbackcoatspecifiedisminimum Thisthicknesswillvaryaccordingtothethicknessofflooringorcladdingmaterial soastosuitthespecifiedlevelorline TheContractorshallberesponsiblefor properbondingbetweenbackingcoat&masonryworkorRCCworkandhisrate shallbeinclusiveofprovidingandapplyingapprovedbondingagent

7)Forallverticalcladding,anapprovedchemicaladhesivefortilesasper manufacturer'sinstructionsshallbeusedandtheratesquotedshallbeinclusiveof thecostofthisadhesive,forathickness3mmto4mm

8)Unlessotherwisespecified,allsizestobeinmetricsystem

9)Scaffoldingforexternalcladdingshallbeofselfsupportingtype Holeswillnot beallowedtobemadeinthemasonryorRCCworkforanchoringthescaffolding

10)Therateforverticalcladdingshouldalsoincludetheworkonisolatedcolumns, chamfers,etc

11)Noseparatepaymentwillbemadeforprovidingandfixing,oddsizedtilesof anyshapeandsizetosuitconsultantrequirement

12)White/ColouredcementwithmatchingpigmentsorJohnsonBALgroutwith appropriatecolourshallbeprovidedbyContractorathiscost

13)TheContractorshallprovidesuitablesupportsforsupportingthecladdingtiles andremoveitonlyafterthetileshavefirmlyadheredtoitslocation

14)Edgesofcladdingtilesfixedonthecornersofthecolumnsandwallsshouldbe polishedasperdirectiveofArchitect,orasindicatedinthedrawings

15)Themaximumthicknessofthepastepreparedbyusingtileadhesiveand appliedonthewallandcolumnsurfacesshouldnotbemorethan3mm

Contractorshallhavenoextraclaimsonaccountofincreaseinthethicknessofthe pastebeyondmaximumthicknessasspecifiedaboveduetofaultyworkmanshipor anyotherreason

16)Mortarrequiredforbedding/backcoatshallbemixedmechanicallyinmortar mill Onlyriversandshallbeusedinthemortar

17)Allfixtures,electricalpoints,lightsetctobealightedwithtiling,groovesand pattern,flushwiththewallfaceasperdetailsanddrawings Amockupforthe sameshallbegotapprovedfromArchitect

18)Thecontractorsarerequiredtostudydrawingscarefullytounderstandfixing detailsofflooring,skirting,claddingetc,tokeeprequiredgroovesbetweendifferent finishesatdoorandwindowlocationsflooringandskirtingjunction,wallandceiling junctionetctomatchflushlinei e verticalplaneofwallandskirtingetc

7
Sr No. Description Qty Unit Rate(Rs) Amount (Rs.)
completeinallrespects 277076 17000 4710292
applyingprimer,putty,etc complete 88008 18500 1628148 633844
j1* j2* TOTALOFSUBSECTION-J K FLOORING&PAVING&SKIRTING

BILL OF QUANTITIES

19)Rateshallbeinclusiveofcostofscaffolding,grouting,curing,finalpolishingby non-slipwaxpolishandcleaningofsurfacesandalsodewatering&keeping surfacedryduringconstruction

20)Asample/mockupofflooring,cladding,etctobegotapprovedfrom,Architect

21)Alladditionalgroovestobeprovidedinvertical,horizontalanddirectionas shownindetaileddrawingsorasdirected

22)Tomakewallcladdingsurfaceandskirtingsurfaceflush,wallatskirtinglevel shallberequiredtorecessinsideasperfixingdetails Thenecessaryrecessesin RCCwalletcshallbetakenatthetimeofconstructionitself

23)Only43gradecementshallbeused

k1 shahabad stoneflooringforclassrooms

Providingandlaying25mmthickhandcutandmirrormachinepolished

,square300mmx300mmfinishedsizeandof approvedcolourandshadeinsmallerpatchesforrepairorinlargerareas including20mmthick1:2limemortarbeddingor1:6cementmortarbedding,tobe compactedproperlybysuitablemethodasapprovedbytheArchitect,beforelaying shahabadstoneinposition

Jointsfinishedwithneatcementslurry,widthofjoint shallbebetween10mmto150mmlayingasperdesign,including3coatsof machinepolishingafterlaying,curing,cleaningcompleteasdirected

b)FirstFloor

k2 green kotahstoneflooring forplinthsandmidlanding,

Providingandlaying25mmthickhandcutandmirrormachinepolished square600mmx600mm finishedsizeandofapprovedcolourandshadeinsmallerpatchesforrepairorin largerareasincluding20mmthick1:2limemortarbeddingor1:6cementmortar bedding,tobecompactedproperlybysuitablemethodasapprovedbythe Architect,beforelayingKotahstoneinposition Jointsfinishedwithneatcement slurry,widthofjointshallbebetween10mmto150mmlayingasperdesign, including3coatsofmachinepolishingafterlaying curing cleaningcompleteas

k3 risersandtreads

k4 dadoofheight1500 5mmthickkotahstone300x300mm

-Do-sameasinitemNok2abovebutfor ,mirrorpolished andmachinecut andsizetomatchthe

k5 anti-skidvitrifiedtilesof300mmx300mm toiletblocksandkitchen

Providingandfixing and10mm thickness(Santron)greycolourfor asdirectedincluding 15mmthickbackingcoatplastering1:4cementmortar,fixingwithadhesivesas specified,jointsfilledwithwhitecementpasteorofapprovedcolourgrouting materialsincludingcuring,scaffoldingetc complete (Overalltilevariation

k6 skirting

-Do-sameasinitemNok1abovebutfor ofheight100mm,mirror polishedandmachinecut20mmthickshahabadstone,andsizetomatchthe jointsinflooring,etccomplete

k7 chinamosaicflooring

Providingandlayinginrequiredposition overconventional waterproofingtreatmentoratgroundleveloverPCCorIPSbaseofapproved colourandpatternon40mmthickbeddingof1:4cementmortarincludingneat cementfloat,givingproperslopes,compaction,curingetc complete

k8 washbasinandkitchencounters

Providingandfixing25-32mmthick ofpolished jetblackgranitestoneofapprovedshape,qualityandcolourincludingrough granitebase,samegranitebothsidepolishedverticalframes,cuttingholesof requiredsizesinappropriatelocationstoreceivesinkpipesetc horizontalshelves asdirectedbyArchitect Doublestonefasciaupto300mmskirting,edge moulding,rounding/polishing,fixinginthecementmortar1:3,curing,cleaning, withallvisibleedgesofgranitestonestobefinishedashalfroundorother specifiedmoulding,withheavygauge(18BWG)stainlesssteelsinkofavg 450mmx600mm,asapprovedofmakeslikeNirali,orCeramiclab(parryware/ Hindustanorapprovedequivalent)etccomplete

k9 PaverBlocks

Providingandlayingprecastconcreteshotblasted,blackcolouredsquarepaving blocksofsize150x150x60mmthkeach(M:35gradeconcrete)ofapproved pattern colourandmake(BasantBetonorapprovedequivalent)ofcompressive strengthof450kg/sqcm,homogeneouscross-section,granitechips,overa50mm thk(orasrequiredtoadjustlevelsonsite)layerofcleansandcushionincluding spreadingsand,layingtheblockstotherequiredslope,leveling,compactingwith vibratorycompactor,fillingthejointswithdrysand,cleaningthesurfaceetc With alllabourandtransportationtositeandasperthedirectionsoftheArchitect

8
Sr No Description Qty Unit Rate(Rs) Amount (Rs)
-- --
47470 35000 166145
a)GroundFloor
19030 35000 66605
directed -- -a)Groundfloor 29500 130000 383500 b)FirstFloor 7640 130000 99320 Sameasitemk2abovebutfor withmouldingfornosing,anti skidgroovesetc complete 1660 -- 26000 4316
jointsinflooring,etccomplete 20535 26000 53391
allowance+10mm)(BasepriceoftileRs500/Sqm) 9160 -- 195000 178620
a)GroundFloor 30240 26000 78624 b)FirstFloor 16660 26000 43316
6970 -- 40000 27880
840 -- 45000 3780
8680 -- 78000 67704

BILL OF QUANTITIES

Notes:

1)CarpentryandJoinery,Timber,Steelcasement,AluminumDoorsWindows, skylightsopenable,slidingwindows,rollingshuttersandpolycarbonatesheet, curtainwalls etc

2)Forallaluminumworks,thecontractorshallsubmitshopdrawingforeachitem ofworkindicatingthesectionofaluminum itsweightandjoinerydetailandtotal weightofwindow/door/partitionwallsetc Whereverpossiblerivetingshallbe resortedtoforconnection Alternativelyhotdippedgalvanizedpinheadedsheet metal/brass,screwscouldbeused Nomildsteelwithouthotdippedgalvanizing shallbeusedforanyfastenings,etc

3)TheratesshallnotbepaidseparatelyforAluminumsectionsusedonweight basis

4) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc

5)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal

6)Alljointsbetweencivilworkandaluminumframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost

7)Ratesforrepairsaswellasprovidingandfixingofnewdoors windows sky light,rollingshutters,etc inthissectionshallbeinclusiveofalltheitemsof hardware/fittingsandnoextrashallbepaidtothecontractortowardsthecostof hardware/fittings

8)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including,fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:

9)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)

10)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand

11)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)

12)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized

13)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete

14)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect

15)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob,Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal

16)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release

17)PlainMorticelocks6leversLatchBoltofGodrejmakeequivalentwithbrass bodyandchromeplatedflatplatetoedgeofdoorincludingfixingtotimberor aluminiumshutterframesetccomplete

18)Sameasaboveitem(16)butwithdeadlock

19) 3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)

20) Doorbufferwithrubber/PVCbushshutterorwallmounted

21)Providingandfixing andrepairrateswillalsobeinclusivealdrops,handles stopperetc allcomplete

D1-SingleleafhingedSunmicadoor

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing 6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete

D2-singleleafhingedwooddoorwithglasspanel

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding

D3-singleleafhingedsunmicadoor

9
Sr No Description Qty Unit Rate(Rs) Amount (Rs) k10 ramps TOTALOFSUBSECTION-K M DOORS,WINDOWSANDPARTITIONS m1 m2 m3 Providingandlaying40-60mm
RoughGranite{shotblasted/flamefinished} Flooring,for orasmentionedunderofsizes12x12m orasmentioned onacementmortarbeddingof1:6with10mmgroovebetweentheslabsand recessedby5mmandfinishedinrichcementslurry 900 -- 130000 11700 1184901
thk
1150 175000 20125
4600 845000 388700

BILL OF QUANTITIES

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal

D4-3panelcollapsiblewoodendoorwithgrillweighing25kg /sqm asper detaileddrawingsanddesignincludingnecessaryanchoring,includingcleaning, sandblasting,threeormorecoatsofepoxypaintetc completetothesatisfaction

D5-3panelcollapsiblewoodendoorwithgrillweighing25kg /sqm asper detaileddrawingsanddesignincludingnecessaryanchoring,includingcleaning, sandblasting,threeormorecoatsofepoxypaintetc completetothesatisfaction

W1- Providingandfixingteakwoodwindowframesalongtheedgeof10mmthick WPCorientable4panellouveredwindow

W2-AluminiumOpenablePanelsWindow

Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium heavysectionsJindalorequivalentmakeforwindows/ventilators,sidehungortop hungopenable/fixedcomprisingofouterframe(035kg/rm) shutterframe(050 kg/Rm),shutter--(040kg/Rm),mullionforouterframe(055kg/Rm),locking handlesandpullhandleforeachshutter,onepairSS frictionhingesforeach shutterand5mmthickclearfloatglassModiorwiredglassorequivalent with neoprene/rubbergasketwithhinges,lockingarrangementandwooden encasementwherevernecessaryincludingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan

W3-FixedwindowsGrills

i)Providing,fabricatingandfixinginpositionboxtype/windowgrills,weighing25 kg /sqm asperdetaileddrawingsanddesignincludingnecessaryanchoring, includingcleaning,sandblasting,threeormorecoatsofepoxypaintetc complete tothesatisfactionofArchitect,etc

W5-Aluminiumopenable4panelslidingwindow

Providing,fabricatingandfixinginpositioncolouranodisedextrudedaluminium slidingwindowsfabricatedoutofextrudedwindowsectionofheavy11/4"seriesof Jindal/orequivalentsections(ie pipes,framesandtracksetc)comprisingof lockingarrangement,55mmthickplainModiglassorequivalentincluding necessaryaccessoriessuchashandles,withneoprene/rubbergasketwithhinges, lockingarrangementandwoodenencasementwherevernecessaryincluding maskingofwindowsillsbeforecompletionofwork,demaskingaftercompletion, cleaning,ratetoincludecolouranodisingallaluminiumsectionstoathicknessof anodicfilmnotlessthan20micronsetc completeasdirected

Notes:

1)Thecontractorwillgivea10yearsguaranteeoftheworkundertakenon Rs100/-Stamppaperontheapprovedformatdulyregistered

2)Tenpercentamountofvalueofworkswillberetainedfortheperiodoffiveyears fromthedateofactualcompletionofthework,willbereleasedprogressivelyat fourpercentaftertwoyearssubjecttoattendinganyrectificationofdefectsand balanceamountsbytheendoffiveyears

3)Allworktobedonethroughspecialistwaterproofingandstructuralrepair agenciesshallbeundertakenonlyontheapprovaloftheArchitect

Providingandapplying70mmto75mmthickproprietarybrandcementbased waterproofing(boxtype)for ,septictanks,effluenttreatmenttanks,etc including providingleak prooftreatmentby injectiongrouting toconcretemembersat10mcentresinboth directionsandalsoatallconstructionjoints,andprovidingandfixing20mmto 25mmthickroughShahabadstoneorotherapprovedstonetilessetin20mmthick 1:3waterproofcementmortarandfinishingthebylaying/plastering with20-30 mmthickC:Min1:3withwaterproofcompound(Contractortogivecomplete specificationsforwaterproofingsystemheproposetocarryout)

Providingandlayingwaterproofingin in allpositionconsistingofspecialisedapprovedwaterproofingcompoundand materialasperspecificationswithallleadandlift

10
Sr. No Description Qty Unit Rate(Rs) Amount (Rs) 2100 175000 36750
ofArchitect,etc complete 1020 000 0
ofArchitect,etc complete 2520 000 0
880 845000 74360
20micronsetc completeasdirected 550 585000 32175
complete 600 299000 17940 W4-Providingandfixingfrostedglass6mmthickforlouvered/glazedwindows 375 468000 17550
4400 559000 245960 833560
104650 140000 1465100
7290 90000 65610
m4 m5 m6 m7 m8 m9 m10 TOTALOFSUBSECTION-M N WATERPROOFING n1* bottomRCCraftslabandsidesofRCCwallsof watertanks n2 WCandbathroomincludingBB coba

Providingandlayingcementbased laidinrequiredslopetodrainthewaterfor anyspanaftercleaningthe basesurfaceapplyingacoat ofcementslurry admixedwithapprovedwaterproofingcompoundandlayingthebrickbatson bottomlayerinC:M1:5admixedwithapprovedwaterproofingcompoundfilling uptohalfdepthofthebrickbats,curingthislayerfor3daysapplyingcementslurry overthislayerjointingofbrickbatswithC:M1:3admixedwithapproved waterproofcompoundandfinallytopfinishingwithaverage20mmthicklayersof cementmortaraddedwithjutefiberat1kgperbagincludingfinishingthesurface smoothwithcementslurryadmixedwithapprovedwaterproofingcompound

Providingandapplyingwaterproofingtreatmentoverchajjausingproprietary cementbasedsystemlikeIndiaWaterproofingusingbrickbatsof50mmormetal no2,averagethicknessoftreatment50mm,finishedwithsmoothcementfinish withfalsetilemarks includingbreaking/removingexistingwaterproofingand cartingawaythedebrisetc

Providingandfillingcementbasedtilejointsealingcompound(JohnsonBalGrout orequivalent)inbath/WC/toilet/flooringtilesincludingrakingoutoldloose jointingmaterial,curingetc

Providingandfixing shallbehoused approximately300mmabovechajjainamortarjointofadjoiningmasonrywall,this sheetctshallbeslopingoutwards Fasteningdown –Thesheets,shallbe fastenedwiththebestSSorBrassscrews/boltsandleadwashersAllen’s,Fisher orotherapprovedfasteningsasdirectedbytheConservationArchitect Thelead sheetingshallbegoodmilledleadnotlessthan10Kg/Sqmbenttotheshape fastenedintothewall groove20mm,withbrass/sswallhookswithjointsatright anglestotheflowbyadripwithaproperlap,iflevelspermit,orby75mmjointsof foldedlead 311921900

TOTALOFSECTION-II

SECTION-IV: MISC

Notes:

1)Rateshallincludeminorcivilwork,scaffolding,electricalworks,dismantling, liasoningcost,steelitems,etc

2)Thequotedpriceshallbeinclusiveofcentralexciseduty,VAT,octroiandservice taxandallotherapplicabletaxes Thisquotationshallnotbesubjecttoprice variationcost

3)Thecontractorshallmakenecessaryarrangementstoprovidesuitablelockable weatherproofstoragespaceforthematerialsandshallalsostacktheexisting dismantledmaterialinasafesecureplaceforthedisposalofthemunicipal authorities

4)Thecontractorshallincludeinthequotation60monthsfreemaintenance,which willbecommencedfromthedateofcompletionofproject

5)Thecostshallbeinclusiveofallpreparatoryworkandnoextracostwillbe providedtowardsthisitem

7) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws etc

6)Forallworksinthissectionasspecifiedbytheconservationarchitect,the contractorshallsubmitshopdrawingforeachitemofworkindicatingthesections materials,its joinerydetailetc Whereverpossiblewoodenpinsshallberesorted toforconnection Alternativelystainlesssteel/brass,screws/boltscouldbeused Noothernails/screwsshallbeusedforanyfastenings,etc

8)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal

9)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost

FabricationandinstallationofInformationSignasspecifiedinthedrawings

Providing&fixinginposition inaluminiumextrudedbrown anodizedsectionwithlettersinvinylonbothsidescoveredwithacrylicsheetand

Providingandfixingseatingaroundtreeasperdrawings Internaldiameterofthe seatingtobeconsideredas15m Seatmadeof150mmdiaSS pipe35mmthick andbackrestof50mmdiaSS pipe35mmthick Bothpipestobebent&grouted intothegroundateitherend Seat&backresttobeweldedtointermediateleg support,eachlegconsistingof2nos 'Z'shapedSS plate4mmthk spaced 40mmapart&connectedat4pointswithSS

TOTALOFSECTION-IV

11
Sr No Description Qty. Unit Rate(Rs.) Amount (Rs) n3 n4 WaterProofingChajja n5 Tilejointfilling n6 TOTALOFSUBSECTION-N 1 a) signageboard 2 waterproofingtreatmenttoterraceand waterdrinkingareawithbricksbats LeadFlashing750mmoverChajja 6970 105000 73185
BILL OF QUANTITIES
complete 550 90000 4950
complete 112800 2500 28200 1100 260000 28600 1665645
asperapprovedsamplebyArchitectfixingasdirected 100 500000 5000
bolts&cylindricalspacers 200 5000

Supply,Installation,TestingandCommissioningofEarthingstationasperIS3043 consistingof40mmGI3000mmlongpipe suppliedwithfunnelattopincluding saltcharcoal,masonrychamber,testlinkbox,hardwareincludingexcavationand masonryworkwithcastironcoverforthechamber

Supply&Layingof followingsizesofstrips &wiresfromearthingchamber/Gridto theelectricalequipment&terminatingthesame Theportionofthestripunder groundshallbelaidatadepthof600mmandonsurfaceshallbefixedwith spacers&clamps&alsoonTray Excavation&allcivilworktobeincluded 25mmx3mmGI stripforDistributionBoard(FirstDistributionBoardinacluster ofDistributionBoards)

8SWGGI EarthingwireforLighting&PowerDistributionBoard

Supply,Installation,testing andcommissioningof3phaseenergymetersuitable forunbalanceloadandincludingnecessarycutoutandjumperwiresetccomplete aspersupplycompany'srequirement

Supply,Installation,testing andcommissioningofTPNMCB16A andincluding ncessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement

Supply,Installation,testing andcommissioningofTPNMCB40A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement

Supply,Installation,testing andcommissioningofTPNMCB32A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement

Supply&InstallationofstandardmanufacturersDistributionBoardforLighting It shallbeastandardBoardwithdoubledoor&suitableforrecess mounting&shall beasfollows Scopeincludesmountingarrangementincludingnecessarysteel, hardwareetcWiresinDB tobeproperlydressedwithbuttontapeandwithlugs, labelsetc

MCB-24Nos

(LDB)

Supply,Installation,Testing&CommissioningofPVCArmouredCablefixedto walls,Ceilingswithclamps,spacerssaddlesorlaidinreadymadetrenchortiedto cablestraywithcableties,tagsetc asfollows 1100VgradeasperIS

Installation,Testing&Commissioningofcables(onwalls,trays) PVCinsulated, 1100Vgrade,steelarmoredasperIS1554withlatestamendmentincluding spacers,saddles,tags, etcThecablesto beproperlydressed

4Cx16SqmmALAYFY

3Cx10SqmmALAYFY

4Cx10SqmmAYFY 3Cx4SqmmAYFY 3Cx6SqmmAYFY 3Cx25SqmmAYFY

TerminationofcableswithHeavydutySiemenstypeglands&lugs Lugsused shouldbeCopperforcoppercables&Aluminiumforaluminiumcable Scopeto includeallmaterial&labourincludingpropertools,Insulationtape

4Cx16SqmmALAYFY

3Cx10SqmmALAYFY

4Cx10SqmmAYFY

3Cx4SqmmAYFY

3Cx6SqmmAYFY

3Cx25SqmmAYFY

Pointwiringforlight,bellpoint ScopetoincludecircuitWiringforlighting&the lightswitchboardwithswitches&furtherwiringtolightpoints Theswitchboard shallberecessmounted/surfacemountedofGIstandardasperthesupplier The pointWiringshallconsistof3x15Sq mmcopperwire,PVCinsulated,1100V gradeinPVCconduit/PVCcasingcaping Thewires&conduitsshallrunfromthe switchboardtotheindividualpoint&circuitwiringshallbeof3x25mm2copper wirefromdistributionboardtothe switchboard Modularplatetypeswitchestobe used6ASwitchSocketonswitchboardtobeincludedInmajorityofthecasesthe lightsaregroupswitchedfromtheDistributionBoardinwhichcasethewireshall be3x25mm2 AllwiresshallbeFRLS

PrimaryLightPointwiringofaveragelengthupto5meterslengthofwire

PrimaryLightPointwiringofaveragelengthupto55to10meterslengthofwire

PrimaryLightPointwiringofaveragelengthupto105to15meterslengthofwire;

12
Sr. No Description Qty Unit Rate(Rs) Amount (Rs) SECTION-V: ELECTRICAL 112800 600000 6768000 ThisitemisworkedoutbytheElectricalConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted 1 EARTHING a 2 EARTHINGSTRIPS/CONDUCTOR a b 3 METER a b c d 4 DISTRIBUTIONBOARD a 5 CABLES&TERMINATIONS a b c d e f 6 TERMINATIONOFCABLE a b c d e f 7 POINTWIRING ai aii aiii
BILL OF QUANTITIES
Incomer40ATPNMCB-1No 40A,30mA,2P,RCBO-3NosOutgoing
6/10ASP

BILL OF QUANTITIES

PrimaryLightPointwiringofaveragelengthupto155to20meterslengthofwire;

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto5metersof lengthofwire3x15sq mmwires

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto55to10 metersoflengthofwire3x15sq mmwires

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto105to15 metersoflengthofwire3x15sq mmwires

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto155to20 metersoflengthofwire3x15sq mmwires

FanpointwiringshallbesameasPrimarylightpointpointwithindividual controlWireofsize3x15sq mmsizeshallrunfromtheswitchboardtothefan pointthroughPVCconduit/PVCcasingcaping ThecircuitfromtheDBtothe switchboardshallbe3x25sq mmwiresSpaceforregulatortobeprovidedinthe switchboard Upto5Metersof lengthofwire

FanPointwiringwiringlength55to10meterlength

FanPointwiringwiringlength105to15meterlength

FanPointwiringwiringlength155to20meterlength

Exhaustfan/WallFanpointswiringshallbesameasPrimarylightpointwith individualcontrol&6Asocket&top@thefanpoint Wireofsize3x15mm2size shallrunfromtheSwitchBoardtothefanpointthroughconduit Thecircuitfrom theDB totheSwitchBoard with3x25mm2wire

Pointwiringfor6Ampswitchsocketpoint Scopetoincluderunningof3x25mm2 copperwire,PVCinsulated,1100VgradeinPVCconduit Wirestoberunfromthe PowerDistributionboardtotheIndividualsocketsupto4socketscanbeloopedon onecircuitWorkstationRawpowerAllwiresshallbeFRLSWiringlengthupto5

meters

6Asocketpointwiringlength55to10meters

6Asocketpointwiringlength105to15meters

6Asocketpointwiringlength155to20meters

Pointwiringfor6/16Amp switchsocketpoint ScopetoincludecircuitfromDB toindividualpoints Conduit,accessories&wireswith3x4mm2copperwiretobe laidfromDBtoindividualsocket TwosocketpercircuittobeconsideredAllwires shallbeFRLSWiringlengthupto5meters

6/16APointwiring55to10meterlengthofwire

6/16APointwiring105to15meterlengthofwire

6/16APointwiring155to20meterlengthofwire

6/16APointwiring205to25meterlengthofwire

Supply,Installation,Testing&Commissioning6Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections

Supply,Installation,Testing&Commissioning6/16Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections

Supply Installation Testing&Commissioningof20AReyrollPlugsocketwith3pin MetalTop,inmetalboardwith20ASPMCB

Supply,Installation,Testing&Commissioningof225mmDia ExhaustFanwith connection

Providingandinstalling,connectingandcommissioning32ATPNSFUwithHRC Fuse

ProvidingandlayingTwopairTelephonecableinexistingconduit/casingcaping Providingandinstallingoutlet fortelephonecable

Providingandinstallingcelingfan1200mmsweepwithfivestepselectronic regulator

Supply&InstallationoflightfixtureswithSigmaBallastincludinglamps,junction boxes,downrod/supports,hardwares rawlplugs,wires/cablesetc asrequired andconnectingittoswitchboards

SupplyandInstallationofPortableEmergencyLightonBatterysuitableforupto10

hours Installite/Canaramake Mountingarrangementforlamptobeincluded 1x18WBracketlight

WST71150withGI waterpipearm1mlongweldedtothecap

WFZ42250

WIF22228SGW

Liasoningchargeswithrespectiveauthoritiesforshiftingofpointofelectrical serviceandothers

Excavationinoutsidesoilincludingrefilling

Supplyinganderectingsteeltubulerpole1651x1397x1143mmthickwith 45x45x365mmthickand(56x27x27mm)respectively11mtrs LongasperIS 2713withtestcertificatefrommanufacturercompleteerecteddulypaintedwithtwo paintsofredoxideandtwocoatsofaluminiumpaintcompleteerectedinposition withMS baseplateof30x30x06cmsthickweldedatthebottomandsuitable polecaperactedwithsetscrewsorwieldedcompleteerectedCC foundationand plinthJunction/Loopingboxincluded

13
Sr No Description Qty Unit Rate(Rs) Amount (Rs) aiv bi bii biii biv ci cii ciii civ d ei eii eiii eiv 8(i) (ii) (iii) (iv) (v) 9a b c d e 10a b 11 12 LIGHTFIXTURESINCLUDINGCONNECTIONANDBULB a b c d e 13 14 15

BILL OF QUANTITIES

16,17and18,ratesshouldbeinclusiveofa comprehensivemaintenancefor60monthsbythevendor

Supplyinganderectingcentrifugalwaterpump(Monoblock)withCI impler, primingfunelcockandcommonflangemountedonacommonshaftofinduction motorof400V3phaseAC supplyofminimum3H P Motorcapableof dischargingwater600to170litesperminutesat125to275meterstotalhead fromallclauseswithfoundationandwith50mmsuctionand50mmdelivery,water pumpshallbeconfirmingtoIS1520complete(Crompton/Kirloskar/Grundfosor anyotherequivalentmake)

Waterlevelcontrollerwithnecessaryprobesforcontrollingmotorforcutoffwhen uppertankwaterlevelisfull whenwaterlevelinthetankcomestopredetermined levelpumpshallstartautomatically When waterlevelinthesuctiontankisbelow thewaterlevel,thepumpshouldnotstart Alsopumpshouldnotrundry The controllershallhavemanual,autoswitchesandselectionofpump Therateshall includenecessarywiringwithcopperwires

DOLStartersuitablefor3HP motorincludingoverload

Providingandfixing25mmPVCconduits/Casingcapingincludingallfittings

Note: Allcataloguenos referredinvariousitemsofsanitaryfittingsareasperHindustan /ParrywareSanitarywareCataloguesandallfixturesareJaguarContinental series

Providingandfixingapproved'Indian make white/colouredglazedvitreous chinawarewallhungEuropeanwaterclosetcisternincluding-

a)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc

b)CIchairsupportsforthewatercloset

c)Whiteorcoloured solidplasticseat&cover veryheavyqualitywith rubber buffersfixedtotheclosetwithCPbrasspillarhinges

100mmdiaconnectorpipefromPtraptothejunctionofthesoilstackonexternal faceofbuilding

ProvidingandfixingapprovedISImarkedmakewhite/colouredglazed'vitreous chinawarewash'handbasincountertoporsuitableformountingbelow'counter comprising:

a)White/colouredglazedvitreouschinawareovalshapedwashbasin size 570mmx425mmwithsupportingMSorCIbrackets

b)1No15mmCPbrasspillarcockwithallfittings

c)1No32mmCPcastbrassbottletrapwithextensionpiecetowall,wallflange withrubberadopterwasteconnection

d)1NoheavyqualityCPbrassangularstopcock15mmsizewithCPbrassflexible connectorpipe Thesupportingbracketshallbeprovidedwith3coatsofapproved paintofapprovedshade

Providingandfixingvitreouswhite/colourchinawareurinalcomprising

a)Largeflatbackwallhungurinalsize250x330x460mm

b)flushingtankof10ltrssupplyingto3urinalswithallfittings

c)CPbrasschromiumplatedflushpipingfromflushvalvetourinalterminatedwith a15mmscrewedspreader

d)32mmdomeCPcastbrasswaste

e)32mmnbCPcastrunningtrapwithextensionpipetowall,wallflange,rubber adopterforwasteconnection

Providingandfixing15mmsizeCPbrassbibtapISImarkedheavyqualityonGI

Providingandfixing25mmthickwhite/colouredgranitepartitionswithmachine cutedges,roundedexposedcornersfixedtowallbycuttingchasesandfixingin

14
Sr No Description Qty. Unit Rate(Rs.) Amount (Rs) Note:Foritemnos
16 17 18 19 A SANITARYSYSTEM 11 12 13 14 15 16 170 18
6768000
800 700000 56000
800 23500 1880
1400 159000 22260
600 300000 18000
lineswithflangeandCPconnectorofapprovedmake 700 40000 280000
cementsandmortar1:4etc complete 600 45000 270000 Size750mmx600mmclearofwall Size1800mmx600mmclearofwall ProvidingandfixingheavyISImarkedmakeheavyqualityCPbrassconcealed typestopcockwithheavyqualitycastwallflange 700 70000 490000 Size15mm ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareOrissawaterclosetcomprising: 700 174000 1218000
SECTION-VI: PLUMBING
TOTALOFSECTION-V

BILL OF QUANTITIES

a)Orissapansize580mmx440mmwithboxriminletwithPorStrapasrequired

b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc 100diaCI connectorpipefromPorStraptothejunctionofsoilstackonexternal

SupplyandfixingHindustanPilkingtonmakemirrors 6mmthickwithplainor bevelededge,8mmthickplywoodbacking,4NosCPbrassscrewswithCPbrass

ThisitemisworkedoutbytheServicesConsultant

Forthepurposeofthiscourseanapproximateamountisbudgeted

Providing laying fixingjointingwithscrewedjointsusingteflontapeGIpipes heavyqualityconformingtoIS1239includingallfittingssuchassockets,unions reducers,longorshortbends,elbows,nipples,flanges,checknuts,clampsetc testingthepipesandspecialsandpaintingthepipesandfittingswithonecoatof approvedprimer&finishingcoatsallasperspecificationsForpipesinexposed conditions:

Providing laying fixingjointingwithscrewedjoints'C'classheavyGIpipes conformingtoIS1239includingallfittings,testing,paintingwithbitumasticpaint protectionwrappingwithHessienfacedpolyethylenetaping&paintingcompleteas perspecifications Forpipelineslaidbelowgroundlevelandlaidinchasesin walls Therateincludesexcavationandcuttingchasesinwallsandreinstatement)

Providing,fixingandtestingheavyqualitygunmetalorbrassballvalvewith screwedends20kgmclassonGIorcopperpipelines(Leader/ZOLOTOmake)

ProvidingandfixinginpositiontestedheavyqualityISImarkedfullwaygunmetal gatevalveofneworequivalentmakehavingbothendsscrewedfemale conformingtoIS778:1984etc complete

i)50mmdia

ii)40mmdia

iii)32mmdia

iv)25mmdia

v)20mmdia

vi)15mmdia

Providing,erecting,fixingandcommissioningPVCoverheadwatertank(BMC approved)includingmakingofproperplatformasperconsultant'sdirection,lifting oftanktoterracefloorlevel placingoftankonplatforminproperalignment makingofinlet/outletconnectionsasperbye-lawsetc complete

i)5000litrescapacity

ii)2000litrescapacity

iii)1000litrescapacity

Providing,fixinggunmetalnonreturnvalveofapprovedquality 80mm 65mm 50mm 40mm 32mm

ProvidingandfixingapprovedISImarkedmakeCIflangedwatermetersdirect readingtypecalibratedinlitres&kilolitrestestedandapprovedbyMCGMwithdirt box(strainer)includingmakingnecessaryflangedjoints testingetc complete

15
Sr No Description Qty Unit Rate(Rs) Amount (Rs)
faceofbuilding 700 23500 164500
capsscrewedtorawlplugsembeddedinwall 400 250000 1000000 Supplyingsinglebowlstainlesssteelsinkofapprovedmakewithwastecoupling& requiredfittingsetc complete 100 300000 300000 112800 150000 1692000 15mmnb 20mmnb 25mmnb 32mmnb 40mmnb 50mmnb 65mmnb 80mmnb 100mmnb
15mm 20mm 25mm 32mm
80mm 65mm 50mm 40mm 32mm 25mm 20mm 15mm
19 1 10 111 B WATERSUPPLYSYSTEM 21* 22* 23* 24* 25* 26* 27*

BILL OF QUANTITIES

40mmsize

50mmsize

Constructingbrickmasonryvalve&meterchambersin230mmthickbrickmasonry incementmortar15usingfirstclassbricksconstructedoverabedof150mmthick cementconcrete1:2:4plasteringinsideoutsideandallexposedsurfacewith 20mmthickcementmortar13,finishing'insidewithafloatingcoatofneatcement providing&fixingCIframe&coversize, weightmentionedbelowpaintingallCI itemswith3coatsofapprovedbitumasticpaintetc complete Chamber600x600mmclearinsidewith600x600CIframe&coverweightingnot lessthan72kgms Depthofchambernotexceeding1000mm

ProvidingStructuralsupportforpipelinesusingchannels,tees,angles,flats& platesfabricationbycuttingthreading&weldingifrequired applyingonecoatof redoxideprimerandthreecoatsofsyntheticenamelpaint,includingnecessary boltsnuts,washeretc asrequiredbytheEngineer-in-charge Theweightofthe supportshallbecalculatedonthebasisofcatalogueweightsofsectionsused (weightofbolts,nutsetc willnotbeconsidered)

Providing&fixingbrassfloatvalveswithbrassrodandcopperfloat suitableto withstandapressure2 kg/sqcm

50mmnb

40mmnb

Excavationintrenchesforpipelinesofrequiredwidthanddepthasdirectedby Engineer-in-chargeincludingtrimmingbottomandsides,excavationforsockets includingrefillingwithselectedexcavatedmaterial(afterlayingofpipeline)in 200mmlayers,wateringconsolidationdisposalofsurplusearthwithin50metc

complete

Inordinarysoil(forCIpipelineslaidoutsidethebuildingonly)depthnotexceeding

15m

-Do-insoftrock

ProvidingandfixingbestIndianmakeCPbrassairvalveswithisolationvalvefixed onGIlines

15mmnbairvalvewith15mmisolationvalve

20mmnbairvalvewith20mmisolationvalve

Providingconnectionstoequipments(Kitchen/Laundryetc includingprovisionof controlvalve,runningjointwithunionetc complete

65mmconnections

50mmconnections

40mmconnections

32mmconnections

25mmconnections

20mmconnections

15mmconnections

SupplyingandinstallingBourdentypepressuregaugesrange0to20Kg/sqcm calibratedbothinpsiandkg/sqcm with10mmbrassgaugecocketc complete

Providingandfixingpipesleevesupto600mmlong,cutfromheavyqualityMS pipesconformingtoIS1239or3589(dependingonsizeofpipewithMSflange conformingtotable13ofIS 6392onbothendsanda6mmpuddleflangeatthe centreofthesleeve,allflangesweldedtopipe,fixingthesleeveinpositionbytack weldingtoreinforcementetc complete

40mmnb

50mmnb

65mmnb

80mmnb 100mmnb

Providingandfixingcastiron traps of selfcleansing design with watersealnot lessthan50mmwith or without vent,including setting the trapin1:2:4cement concreteetc complete Thetrapshall be `P' or `S'type as required Trapwith 100mm inlet and100mmdiaoutlet

Asinitem31buttrapwith75mmoutlet

Asinitem31buttrapinPVC

Asinitem32butwithPVCtrap -Do-gratingofsize150mmx150mm

Providingandfixingstainless steel gratingof 18 gaugethick withcircular perforationofapprovedpatternoverCItraps Thegratingshallbeofsize100mmx 100mmorcircularof100mmdia(asdirected) and shallbesetin cement,sand mortar1:3etc complete

16
Sr No. Description Qty Unit Rate(Rs) Amount (Rs.)
28* 29* 210* 211* 212* 213* 214* 215* C INTERNALDRAINAGESYSTEM 3.1* 32* 33* 34* 35* 36 ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted

BILL OF QUANTITIES

Providing fixing jointingand testingPVCWCpanconnectorofapprovedcolour with or withoutvent horn all as perrequirementsofEngineer-in-charge Size 100mmi/d-Length300mmto400mm

Supplying,laying,fixingjointing&testingheavyISImarkedcastiron spun soil pipes/centricastpipesincludingallfittingswithorwithoutinspectiondoors,vents, cowls at topetc jointing with leadcaulked joints all as perspecification and as directedbyEngineer-in-charge

150mmi/d

100mmi/d

75mmi/d

65mmi/d

50mmi/d

Providing, laying, jointing with screwed jointsusing teflon tape GI pipesof classTataorZenithconformingtoclassheavyofIS1239withallfittingstestingthe piping, painting with 2coatsofbitumasticpaintwrapping with Hasseinfaced polyethylenetapeintwo layers and againpaintingwith2coatsofbitumastic paint Therateincludesforcuttingchasesinwall&floorsforembeddingthepipe andreinstatementofsurfacetooriginalconditions

50mmi/d

40mmi/d

32mmi/d

Providing and fixing inposition cast iron rain water inlets withgravelguard anddometypegratingspeciallycastgenerallyconformingtodrgs

Inletfor:

150mmi/dpipes

100mmi/dpipes

Providing and fixingleadsheet flashing madeoutof3mmthickleadsheets settinginalayerofcoldbitumenetc complete Thesheetshallprojectatleast 150mmallaroundthepipeand shallbetuckedintothepipeatleastby100mm

150mmi/dpipes

100mmi/dpipes

ProvidingandfixingMSsupportsforpipesfabricatedfromMSflatsanglesand platesincludingfixingthebracketstowalls slab beametc withanchor fasteners 12mm'U'or'J'boltsforfixingthepipestoclamppaintingwithonecoatofprimer andtwocoatsofapprovedpaintetc complete

Providingandlayingcementconcrete1:2:4forbedding,envelopeshaunchesetc forthepipesincludingmixingplacingformworkcuringetc complete

SupplyinglayingfixingjointingandtestingPVCdrainagesystem(SWR)including fittingswithorwithoutinspectiondoors,vents,cowlsetc allasdirectedby engineerincharge 110OD 75OD

ProvidingandfixingPVCplainor multi floor traps of selfcleansingdesignwith watersealnotlessthan50mmwithorwithoutventincludingsettingthetrapsin cementmortaretc complete Trapswith125mminletand75mmoutlets

Providingcleanoutsincastiron drainpipingcomprisingGIheavyclasssocket andscrewed plug,connectingCI pipewithleadcaulked jointetc complete 150mm 100mm 75mm

Supply,laying,jointingandtestingPVCpipesincludingallmouldedfittings conformingtoIS4985(10Kg/sqcmvariety)etc complete

ProvidingandfixinginpositionheavyISImarkedlongarmCI nahanitrapofIS 1729weighing9kgofNecoorEquivalentmakeofsize100x75x500mmdiaoutlet includingembeddingonflooringatrequiredlevelwithM150cementconcreteall aroundandbelowthetrap,supplyingandfixingbrassCP squaregratingofsizeof 150x150mmwithbrassCP coverplateasspecifiedetc complete

Providing,fixingandjointinginproperalignment&positionheavyISImarked 50mmdia CI pipeofNecoorEquivalentforventconformingtoIS1729withall necessaryfittings likeoffset bend cowletc includingerectionofscaffoldingat requiredlevel,makingholesinwallsasrequired,fixingofpipe&fittinginposition, leadjointing/fillingofjointswithCM1:3(onlyonapprovalofconsultant), reinstatementofsurfacesetc complete

17
Sr No Description Qty. Unit Rate(Rs.) Amount (Rs) 37* 38* 39 310* 311* 312* 3.13* 314* 315* 316* 317 318 319
50mm
40mm
32mm
OD
OD
OD

Providing,fixingandjointinginproperalignment&positionheavyISImarkedCI CentripipesofKapilanshorEquivalentmake(withinbuildingline)fordrainage conformingtoIS3929of150mmdiameter sizewithallnecessaryfittings like offset,bend,etc includingexcavationuptorequiredlevel,makingholesinwallsif required,layingofpipeatpropergradient,leadjointing/fillingofjointswithCM1:3 (onlyonapprovalofconsultant),reinstatementofsurfacesetc complete

Providingandconstructing300x300mminternalsizebrickmasonrygullytrap chamberincludinglayingof100mmthickPCC1:3:6inbed,115mmthickbrick wallsinCM1:5,fixingofglazedstonewaregullytrapofsize150x100mm, makingconnectionofwastewaterpipetoit,plasteringinsidethechamberwithCM

1:3toformhopper,fixingofheavyCI coverwithframeweighingnotlessthan7

kg inPCC1:2:4&makingflooringlevelontopetc complete

Providing,layingandjointingISImarkedfirstquality‘A’gradesaltglazed stonewarepipe&bend includingexcavationtothelevelofrequireddepth laying of100mmthickPCC,placingofpipeonPCCasspecifiedatproperalignmentand gradient,sealingthejointswithtarredgasketofhemporropeyarn,caulkingwith cementmortar1:2,testingofpipeline,encasingofpipeasspecified,curing, refillingetc complete

i)100mmdia

ii)150mmdiafordepthbetween045and060Mtrs

iii)150mmdiafordepthbetween060and100Mtrs

Providing&fixing150mmdiameterISImarkedfirstquality‘A’gradesaltglazed stonewaresewertrapasspecified

i)150mmdiameter

Constructingbrickmasonryinspectionchamberofsizeof900x450mmanddepth asmentionedinitw\esmbelowincludingexcavationupto requireddepth,layingof 100mmthickPCCfoundationbedin1:3:6mix,230mmthickbrickworkinCM1:3, 20mmthickplasteringofwallsinside&outsideasspecified makingofsmooth channel&haunchinCM1:2,150mmthickPCCcopingontop,fixingofCI manholecoverofNecomakeweighingnotlessthan75kg,backfilling,removalof surplusearthasspecifiedetc complete

i)Depthbetween045and060m

ii)Depthbetween060and100m

PlantingofFloweringtreesonsoftsurface:

Diggingofpitforplantationoftreebyexcavatingthegroundintheearth/murum/ sandof10mx10mx10msize removingexcavatedmaterialfromsite filling RedHillEarth(033Cum),Cowdungmanure(033Cum)andgoodexcavated earthfrompit(033Cum),mixingofRedHillearthandcowdungmanureand plantationoftreesapling,stakingoftreesapling,preparationoftreebasin, levelling,wateringandmaintainingfor30dayssftercompletionofplantationand

PlantingofFloweringtreesonhardsurface:

Diggingofpitforplantationoftreebyexcavatingthegroundintheconcrete/ masonary/asphaltof10mx10mx10msize,removingexcavatedmaterialfrom site,fillingRedHillEarth(033Cum),Cowdungmanure(033Cum)andgood excavatedearthfrompit(033Cum),mixingofRedHillearthandcowdung manureandplantationoftreesapling,stakingoftreesapling,preparationoftree basin,levelling,wateringandmaintainingfor30dayssftercompletionofplantation

18
Sr No Description Qty Unit Rate(Rs) Amount (Rs) 320 321 322 323 324* A* Developmentwork a1 a2 B* Providingplantsandtreesaplings: b1* b2* b3* b4* b5* b6* b7* b8* b9* b11* b12* b13*
BILL OF QUANTITIES
(Excludingcostoftheplant) 000 SQMT 000 0
replacementofcasualtiestill30days
andreplacementofcasualtiestill30days (Excludingcostoftheplant) 000 SQMT 000 0 Plant1 1000 Nos 000 0 Plant2 1000 Nos 000 0 Plant3 1000 Nos 000 0 Plant4 1000 Nos 000 0 Plant5 1000 Nos 000 0 Plant6 1000 Nos 000 0 Plant7 1000 Nos 000 0 Plant8 1000 Nos 000 0 Plant9 1000 Nos 000 0 Plant10 1000 Nos 000 0 Plant11 1000 Nos 000 0 Plant12 1000 Nos 000 0 398175550 TOTALOFSECTION-VI: PLUMBING SECTION-VII: LANDSCAPINGANDGARDENING TOTALOFSECTION-VII: LANDSCAPINGANDGARDENING 1827365 0 GRANDTOTAL(SECTIONSI+II+III+IV+V+VI+VII)

MEASUREMENT SHEET

ForallItemsinallSections:Rateshallincludetransportation,loading/unloading,providing/supplying/laying/fixing/installing/ fabricating/testing/commissioningetconsite RateshallalsoincludealltaxessuchasVAT excise salestax octroi etc

SECTION-I: SitePreparation&Cleaning

Cleaningandclearingthesiteofallrocks,boulders,brick-bats,stone,bushes, shrubs,etccomplete,asdirectedbythearchitectforstartofconstructionactivity

SECTION-II: CIVILWORK

Note:

1)TheitemsgivenbelowshallbeasperSectionA""Earthwork MetalPacking& SubsurfaceDrainage"ofthespecifications

2)Rateforexcavationshallincludedewateringduringtheexcavationincluding shoring,struttingetcandkeepingitdryduringexcavationandconstruction

3)AllearthworkshallbecarriedoutasperConservationArchitect'sinstructions andsafetynormsasperrelevantIScode Therateshallincludeallscaffolding andmeasuresforcordoningoffareasduringdismantling,providingsignboards etc

4)Alldebrisandscrapmaterialsfromearthworkshallbecontractorspropertyother thanthatwhichisreusedforback-fillingetc andthisdebrisandscrapmaterials shallberemovedawayfromsiteimmediatelyonhisown Thecontractortogive rebateinratesagainstmaterialsandscrap/debrisfromsuchdismantledwork whichshallbecontractor'sproperty

5)Forallearthworkitems thecontractorshouldcarefullystackallexcavated materialatsiteaspertheinstructionsoftheConservationArchitect Alldebris associatedwiththeearthworkshouldhoweverbedisposedoffbytheContractor

6)Themeasurementofexcavationshallbetakenincum asperrectangular trenchofbottomwidthofconcretemultipliedbyverticaldepthoffoundationfrom groundeventhoughcontractormighthaveexcavatedwithslopingside/fulllength trenchforhisconviency

andexcavationforretainingwalls,basement,watertanks, effluenttreatmenttanks etc includingbackfillingofapprovedexcavatedmaterials infoundations, &behindretainingwallsaftercompletionofwaterproofingetc wateringandconsolidating,cartingawaysurplusearth, includingpreparingthe surface (Note:Allbackfilling&spreadingofearthshallbecarriedoutinlayersnot exceeding200mmandcompactedto90%ordinaryproctordrydensity)

andinotherplaceswithapproved broughtfromoutside, includingwateringconsolidatinginlayersnotexceeding200mmby8-10tonnes roadrollerorotherapprovedmechanicalequipmentetc

:(AsperIS:6313Part-III)(Note: Anti-termitetreatmentshallbecarriedoutthroughspecialisedagencyreputedin PestControltreatmentandapprovedbytheArchitect Thecontractortogive10

Providing bydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC ISIapprovedconforming(IS8944) Includingtreatmentofwoodfor

Providing bydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor termites borers wetrotsanddryrots Coveredfloorareashallbemeasuredfor payment

Providing,chasing,inserting/laying 50mmthickM-20 cementconcretelayerandbitumenusingcementwithapprovedwaterproofing compoundattherateof1Kgper50kgofcementetc complete

Note:

1)TheitemsgivenbelowshallbeasperSectionB"Concrete-Plain&Reinforced" ofthespecifications

2)ForsmallconcreteonapprovalofConservationArchitect,weighbatched concreteasperdesignmix,inmanuallyormechanicaltypeoperatedweigh batcherdialtypeormechanicaltypeofminimumcapacity650Kgsshallbeused Weighbatchershallbecalibratedregularly

3)Forallmajorconcretepours,Contractorshallusereadymixedconcrete(RMC) ofUnitechPrefabLtd orM/s Larsen&ToubroLtd approvedAgencies Only53 gradecementshallbeusedinRMC Aggregatepropertiesandgradingdesign mix,quantityofsuperplasticiser,settingtime,amountofslumpatthepouringsite shallbegotapprovedbeforeitsuseineachmajorconcreting

4)Concretemixproportionwillbebasedon50kg weightofcementbags deliveredatthemixer

1
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units a1 A EARTHWORKANDMETALPACKING a1 Surfaceexcavation a2 Fillinginplinth murum a3 Anti-termitePreconstructionTreatment a4 post-constructionalanti-termitetreatment (GroundFloor) a5 post-constructionalanti-termitetreatment (FirstFloor) a6 Dampproofcourse B CONCRETE-PLAIN&REINFORCED
131740 350 -- 46109 CUM
completeasdirected 116740 350 -- 40859 CUM
yearsguaranteeonasuitablebond) 76320 300 -- 22896 SQ M
Coveredfloorareashallbemeasuredfor payment 83130 -- -- 83130 SQ M
termites,borers,wetrotsanddryrots
30510 -- -- 30510 SQ M
25980 300 -- 77940 SQ M
25000

MEASUREMENT SHEET

5)TheContractorisentirelyresponsibleforthedesignofconcretemixes The designishowever,tobeapprovedbytheArchitect

6)ConcreteM-20/20meansconcretemixM-20gradeusingmaximumsizeof coarseaggregates20mm

7)Shuttering formwork centeringshallnotbepaidseparatelyandshallconform toSection-C

8)Curingcompoundmaybepermittedonlyforinaccessiblelocations

9)OnlyRiverSandshouldbeused Washingofsandinrotaryscrewtypewashing machinesisamust

10)RatesshallbeinclusiveofcostofSuperplasticiserofapprovedqualityandof approveddosage

11)Ratesshallbeinclusiveofprovidingpockets holes inserts pipes etc

12)Mechanicalvibrators,internaland/orexternaltobeused

13)AlldefectiveconcreteifapprovedbyArchitect,shallberepairedbythe contractorathisowncost usingapprovedepoxymortarorPolymermodified mortarasperManufacturer'sspecifications

14)Therateshallincludethecostofapplying2coatsofpolymerbondingagenton allsurfaceofoldornewconcreteatconstructionjointpriortoconcretingagainst thesame

15)Useoffinesandwithpropergradingisamust

16)Screeningofmetal-IandIIforremovingexcessiveflakyunderandoversize material,stonedustetc isamust

17)Onlyapprovedmouldreleasingagentshouldbeused

18)Cleaningofshutteringplatesbymechanicalbuffingaftereveryuseisamust

19)Allconcretesurfacesshallbeformfinished

20)Whereplasteringisspecified,concretesurfacesarerequiredtobehacked immediatelyaftertheremovalofformworkasdirectedbytheArchitectwherever required Additionalrateshallnotbepaidtocontractorforhacking

21)Contractorshouldmakearrangementfortablevibratorforcastingthecover blocksofrequiredsizeandgrade

22)Rateshallbeinclusiveofprovidingcoverblocks Coverblocksshallbemade ofthesamegradeofconcreteofstructuralmemberinwhichtheblocksaretobe used

23)Alljointsinshutteringshallbesealedbyuseof5mmthickcompressible materialgasketsandfixingagent

24)Constructionjointshallbeminimuminnumbersandtheirlocationshallbe approvedbytheConsultant Constructionjointsshallbetreatedproperlywith bondingcoatofapprovedmaterialtobeappliedattheoldconcretebefore commencingthefreshconcretingoperations

25)Informfinishsurfacesthepatternstobeprovidedfortheformworkshallbeas perarchitectssuggestions

26)Allsack-rubbedsurfaceshallbesackrubbedwithwhitecementofsuggested proportionasperArchitectsapproval

27)Allconcealeditemslikeconduits,junctionboxes,fixturesetc shallbelocated asperdetailsandlocationstobeapprovedbeforecasting

NotesforFormwork:

Note:1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications

2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping

3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup thecontractor willbeallowedtoproceedwiththework

4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed

5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorathiscost

6)Ratesquotedshallbeinclusiveofallformworkatalllevels

7)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates

8)Onlyapprovedmouldreleaseagentshouldbeused

9)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust

10)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork

11)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect

12)Providingcutouts holes slits depressionetc forelectricalfixturesshallnotbe paidseparately

13)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect

14)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel andverticalityoftheshuttering stagingtoachieve requireddegreeofperfection

15)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant

2
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units

MEASUREMENT SHEET

ProvidingandlayingConcreteM20/40usingRMCforall includingsideformsifrequired Therate shallbeinclusiveofalltaxes towardsplants&machinery labour allleads&lifts allfloorsallchargesrequiredincludingtransportation,centering,formwork, compacting,rougheningthesurfaceifspecialfinishistobeprovidedandcuring

ProvidingandlayingconcreteM25/20using on gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper

ProvidingandlayingconcreteM25/20using on gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,allfloors allchargesrequiredincludingtransportation shuttering centering formworkasper

ProvidingandlayingconcreteM25/20using on gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc

Providing&layingM30/20 using ,column,walls,shearwalls,boxcolumn,retaining walls,plinthbeams,floorbeams,invertedbeams,slabs,staircase,droppardis, chajja,parapets,pergolas,trenchslabandbeamsinstructuralfloors,loftslabsat alllevels,lintelbeams/verticalstiffenersetcincludingRCCundergroundwater tanks septictanks effluenttreatmenttanks overheadwatertanksetccomplete Therateshallbeinclusiveofalltaxes,towardsplants&machinery,labour,all leads&lifts,allfloorsallchargesrequiredincludingtransportation,shuttering, centering,formworkasperconditionsbelowetc

ProvidingandlayingconcreteM25/20using ongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery labour allleads&lifts allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc

Providing&layingConcreteM20/40,usingRMC,inalternatebaysfor andpavingincludingcompacting,vibrating,curing,finishingtocorrect line&levelwiththeuseofwoodenbottomandsurfacefinallyfinishedwithbrooms asdirectedbyArchitect Jointsofandasprovidedinalternatebaysshallbefilled withbitumenetc allcompletetothesatisfactiontotheArchitect

Providingandconstructing includingexcavationin alltypesofsoil refillinginsidesoftank trimming dressing leveling stackingand disposalofsurplussoilandincluding:

i)Rubblesoling230thk

ii)PCC M20/30belowraft

iii)M-25/20RCCworkinraftslabs,sumpbase,beams,RCCwalls,columns,top slabsetc includingunwrotshutteringtoRCwallsatalllevels

iv)TMTreinforcement

v)Waterproofcementplastertoinsideofwatertanks

vi)BoxtypewaterproofingtreatmentforraftandwallsofUGtank

vii)Patentedcementbasedwaterproofingtreatmenttotopofslabs

viii)50mm thk IPStoraftslab

ix)Providingandfixingcastironmanholecovers2nos 600mmdia withlocking arrangements

x)PVCwaterstop150mmdia;embeddedintakeandoutletpipesetc

Providing,erecting,fixingandcommissioningSintexorapprovedequivalent doublelayeredtanksonoverheadelevatedpedestalasdirectedincluding scaffoldingallalliedplumbing,valves,stopcocks,MCGMcertifiedwatertankcap, includingcleaningetc

Notes:

1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications

2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping

3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup thecontractor willbeallowedtoproceedwiththework

4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed

3
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units b1* PCCworksbelowraft slab,plinthbeams,foundations,etc b2* RMCforRCCworkoffloorslab (GroundFloor) b3* RMCforRCCworkoffloorslab (FirstFloor) b4* RMCforRCCworkoffloorslab (SecondFloor) b5 RMCforRCCincludingpumpingfor foundation,pilecaps,raftslab b6 RMCforstaircase b7 Brickjali b8 plinth protection b9 RCCundergroundwatertank b10 C FORMWORK
etccomplete 104738 015 -- 157107 CUM
conditionbelow etc complete 96712 015 -- 145068 CUM
conditionbelow,etc complete 43064 015 -- 64596 CUM
complete 5090 015 -- 7635 CUM
complete a)RaftSlab 100780 035 -- 35273 CUM b)RaftCellularWalls 14950 300 -- 4485 CUM
complete 1830 015 2745 Providingandlaying asperdesign&sizeapprovedbytheConsultant 8910 -- 280 24948 SQ M
25980 075 -- 19485 RUNNING MT
litres
1000000
UGtankcapacity 1000 130 13500 CU M
completeasperthesatisfactionoftheArchitect 314 180 200 6570 Cu m

MEASUREMENT SHEET

5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorat hiscost

6)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates

7)Onlyapprovedmouldreleaseagentshouldbeused

8)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust

9)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork

10)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect

11)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately

12)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect/consultants

13)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection

14)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant

ThisitemisworkedoutbytheStructuralConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted

Notes:

1)TheitemsgivenbelowshallbeasperSectionD:'Reinforcement'ofthe specifications

2)CoverblocksshallbeofgoodqualityconcreteM30/10andshallbevibratedon atablevibratortoreducethepermeability

3)Whereverweldingofreinforcementisspecified,thesameshallbecarriedout conformingtoIS:9417orIS:2751 Weldingshallbecarriedoutbyapproved qualifiedweldersonly Onepercenttestingofweldsshallbecarriedforalltypesof welds

4)Overweightofthesteelshallnotbeconsideredforcalculatingconsumptionand paymentpurpose,IS constantforweightofdifferentdia ofbarsshallbe consideredforpaymentaswellasconsumptionpurpose

5)Columnreinforcementbarsarerequiredtobelappedinthemiddleportionof columnsasperIS13920 Properarrangementshallbemadetosupport reinforcementprojectingabovefloorlevel Similarlylapswithinadistanceof2D (depthofbeam)or1/4spanfromthefaceofthecolumnarenotallowed The overhangingbarsshouldbeproperlysupported Thecostoftheseworksis deemedtohavebeenincludedintherate

ProvidingandfixinginpositionmildsteelreinforcementofTATA/Vizag/SailSteel ofvariousdiametersforRCC piles,pilecaps,footings,foundations,slabs,beams, columns,canopies,staircases,dowels,chajjas,lintels,pardis,copings,fins,arches etc asperthedetaileddesigns,drawingsandschedulesincludingcutting, welding,bending,hookingthebars,bindingwithGIwiresandconcretecover blocksetc complete Noseparatepaymentforchairs laps wastageandbinding

Supplying,fabricating,erecting,aligninginposition,fixing,StructuralSteel ofTATA /Vizag/SailSteelinalltypesofmembers(Box Ropes I-sections C-sections L-anglesetc)forColumns,Beams,TrussRafter,Purlinforroofs,lofts,stairs, mezzanines,storageracksforparaffinboxes,portals,braces,underpinning, shoring,frames etc Theratetoincludecutting,anchorfasteners,bolting, welding wastageandapplicationofepoxybasedpaints(Asianmake)asper manufacturer'sspecificationsandasdirected

Providing,fabricating,erectingandfixingatalllevelsstructuralsteelofTATA/ Vizag/SailSteelinalltypesofmembersforColumns Beams TrussRafter Canopies,roofcovers,purlinforroofs,lofts,mezzanines,storageracksforparaffin boxes,portals,braces,underpinning,shoring,frames,workforallstructuraland otherpurposes,includingcuttingedgestotherequiredprofile,bolting,welding, anchorfastening riveting groutingetc completeinallrespects includingepoxy paintingasspecifiedine3 kg

4
No Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr
147130 147130 SQMT
wirewillbemade
Therateshouldincludepaintingof thesteelasstatediniteme3below Squarehollowsections200mmx200mm 480 480 MTTON
i)Usingrolledangletrussouterframe75x75x8 17088 500 8544 kg ii)Usingrolledangletrussinnermembers75x75x6 10200 500 510 kg ii)purlinsismc75 13490 900 12141 kg i)Usingrolledangletrussouterframe75x75x8 11748 400 46992 kg ii)Usingrolledangletrussinnermembers75x75x6 7000 400 280 kg ii)purlinsismc75 11360 600 6816 kg i)Usingrolledangletrussouterframe75x75x8 18957 300 56871 kg ii)Usingrolledangletrussinnermembers75x75x6 11356 300 34068 kg ii)purlinsismc75 9940 1000 994 kg D REINFORCEMENT d1* E STRUCTURALSTEELWORKSANDOTHERFABRICATIONITEMS e1 e2*

MEASUREMENT SHEET

PaintingofSteelWork

Supplyingpaintingandothermaterialsandlabourrequiredforpaintingofstructural steelasdetailedbelow:

i) Surfacepreparation:

Mechanicalcleaning,removinglooserust/scaleusinghardtools,powertools,use ofaromaticsolventstoremovesoil/greasepresentandtoensureacleananddry surfacebeforepriming

ii) Primer:

SinglecoatofEpoxyresinandzincphosphateoftotaldryfilmthicknessof25 microns

iii) Finish-Coat1:

Singlecoatofhighbuildchlorinatedrubbermediumwithmicaceousironoxideof totaldryfilmthickness of75microns

iv)FinishCoat2&3:

Twocoatsofplasticchlorinatedrubbermediumsuitablypigmentedof25microns dryfilmthickeach TotalDFTofpaintsystemshallnotbelessthan200micron

Providingfabrications,erectingandfixing

SS Railing

i)SS PoleMadein16gauge50mm DiameterISapprovedSS304pipewitha

Note:

Measurementshallbetakenforcompletelaidroofinsquaremeter Overlapswill notbepaidextra Therateshallincludeallthematerial,labourbolts,nut,washers andtoolsandplantsetc complete

SteelFramedRoofingSystem

Providing supplyingandinstallingcellular(doublewalled)polycarbonatesheet/ tetrapacksheet(dupontorequivalent)roofinginclusive offixingtostructuralsteel supportsystemasperdesignandmanufacturer'sspecification Thecostshallbe inclusiveofalltaxes Allnecessaryscaffolding,craneandaccessoryworktobe usedincarryingouttheworksistobeincludedinthecost Thecontractorshall havetotakeduecareofthesurroundingbuildingandseetoitthatthefacadeskin anditselementsarenotdamagedintheprocessofcarryingoutthiswork

Providingandfixingofflashingofallsizesforf1above

ThisitemisworkedoutbytheConsultant Forthepurposeofthiscoursean approximateamountisbudgeted

Note:

1)Theitemsgivenbelowshallbeasper'MasonryWork'ofthespecifications

2)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction

3)CementformanufacturingconcreteblockstobeprovidedbyContractor

4)Onlyselfsupportingscaffoldingwillbeallowed,noholesinmasonrywouldbe permitted

5)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc

6)Factoryincludingblockmakingmachineformanufacturingofconcreteblocks shallbeapprovedby Architect-in-charge

7)Thecementforblockmasonryshallconfirmtotherequirementofminimum cementrequirementforPCC ofconcretespecifications

8)Requiredquantityofconcreteblocksaretobemanufacturedwithgroovesto accommodatetheconduitpipes/waterpipesetc Thegroovesshouldbestaggered onbothsides

9)Therateforconcreteblockmasonrywallsshallbeinclusiveofproducinghalf blocksandoddsizedblockstosuittheconstruction

10)Mortarsforallmasonryworkshallbemixedinanapprovedmortarmixeror concretemixer

11)Handmixingofmortarwillnotbeallowed

12)Onlyriversandand43gradecementshallbeused

13)Washingofsandinrotaryscrewtypewashingmachinesisamust

14)Bricksusedshallbeoffirstclassandshallbeofregularinshapeandtheir edgesshouldbesharpandshallbefreefromcrack Brickshallbefullysoakedin cleanwaterbysubmerginginatankforaperiodof12hoursimmediatelybefore use

15)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical telecommunicationandwatersupplyandplumbingetc

LengthofRunningWall

5
Sr No. Description Quantity PLineArea/Perimeter Height/Width No Total Units i)Usingrolledangletrussouterframe75x75x8 17088 600 102528 kg ii)Usingrolledangletrussinnermembers75x75x6 10200 600 612 kg ii)purlinsismc75 17750 900 15975 kg TOTAL 91 MTTON
ornamentalSSringatthebottomendsSS topatapexforassemblyofupper Handholdpipewholeunitprovidedwithmirrorfinish (Foraheightof12M) 6540 -- 000 1635 KG
LengthinPlan InclinedLengthinSection
79400 000 -- 79400 SQM
e3 e4
F
f1 f2 G MASONRYWORK
ROOFING

MEASUREMENT SHEET

g1 brick (GroundFloor)

Providingandlaying (firstclass)masonrywallin1:6C:M aboveplinthorat alllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstriking joints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15 Bag/cum)

350mmthickbrick 230mmthickbrick 150mmthickbrick

g2 brick (FirstFloor)

Providingandlaying (firstclass)masonrywallin1:6C:M,aboveplinthorat alllevelsincludingforoddshapedwalls brickfins columns etc includingstriking joints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15 Bag/cum)

230mmthickbrick 150mmthickbrick

g3 PCC/stonestonecopingoverterraceparapet

having dimensions450mmwide100mm thicknessinpiecesof600mmlengthovera

g4 RCCLintels (GroundFloor)

350mmwide 230mmwide 150mmwide

g5 RCCLintels (FirstFloor) 230mmwide 150mmwide

g6 RCCSill (GroundFloor) 350mmwide 230mmwide

g7 RCCSill (FirstFloor)

H PLASTERING,POINTING

Notes:

1)Theitemsgivenbelowshallbeasper'Plasteringofthespecifications

2)Scaffoldingforplasteringshallbeofselfsupportingtype Holeswillnotbe allowed,tobemadeinthemasonryorRCCworkforanchoringthescaffolding

3)OnlyRiverSandshouldbeused Howeverwashingofsandinrotaryscrewtype washingmachinesisamust

4)Mortarforplasteringworkshallbemachinemixedinamortarmixerorconcrete mixer Handmixingofmortarwillnotbeallowed

5)Therateforplasteringshallalsoincludeprovidingandmixing/applyingan approvedbondingagentasperdirectionofArchitect-in-charge,andalsoapplying approvedhack-aidonsurfacereceivingplaster

6)Only43gradecementshallbeused

7)Rateshouldbeinclusiveofscaffoldingandcuringshallbestartedassoonas theplasterhashardenedsufficientlynottobedamagedwhenwatered Theplaster shallbekeptwetforatleast10days

h1* Internalcementplaster (GroundFloor)

Providing12mmthick intwocoatsincementmortar1:4 with/withoutneeru,finished smoothforallRCC/brickblockmasonrywork includingcuring,andscaffoldingetccomplete

h2 Internalcementplaster (FirstFloor)

Providing12mmthick intwocoatsincementmortar1:4 with/withoutneeru,finished smoothforallRCC/brickblockmasonrywork includingcuring,andscaffoldingetccomplete

h3 plasterexternally (GroundFloor)

Providingsandface intwocoatsusingapprovedscreened sandinallpositionincludingprovidingbasecoatof18mmthickincementmortar

1:4mixingapprovedwaterproofcompoundattherateof1kg/50kgofcement andcuringthesamefornotlessthantwoweeksandkeepingthesurfaceofbase coatroughtoreceivethesandfacedtreatment8mmthickincementmortar1:4 andfinishingthesurfacebytakingoutgrainsandcuringfor14daysincluding preparingsurface,wateringandscaffoldingetc

6
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No.
a) 18010 280 - 44138 SQMT b) 14770 280 - 34686 SQMT c) 5260 280 - 12478 SQMT
a) 12890 280 - 3231 SQMT b) 2800 280 - 694 SQMT Providingandfixing
mortarbeddingofCM1:6/Limemortar1:3 3360 -- 3360 RUNNING MT Providingandfixing inpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3 a) and150mmthickness 1687 015 25305 CU MT b) and150mm thickness 1220 015 183 CU MT c) and150mmthickness 230 015 0345 CU MT Providingandfixing inpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3 a) and150mmthickness 740 015 111 CU MT b) and150mmthickness 090 015 0135 CU MT Providingandfixing inpiecesof600mmlengthoveramortarbeddingof CM1:6/Limemortar1:3 a) and150mmthickness 1134 015 1701 CU MT b) and150mmthickness 560 015 084 CU MT Providingandfixing havingdimensions230mmwide150mm
inpiecesof600mmlengthoveramortarbeddingofCM1:6/Limemortar 1:3 506 015 0759 CU MT
thickness
203520 280 -- 203520 SQMT
85516 280 -- 85516 SQMT
complete 61436 280 -- 61436 SQMT

MEASUREMENT SHEET

Providingsandface intwocoatsusingapprovedscreened sandinallpositionincludingprovidingbasecoatof18mmthickincementmortar

1:4mixingapprovedwaterproofcompoundattherateof1kg/50kgofcement andcuringthesamefornotlessthantwoweeksandkeepingthesurfaceofbase coatroughtoreceivethesandfacedtreatment8mmthickincementmortar1:4 andfinishingthesurfacebytakingoutgrainsandcuringfor14daysincluding preparingsurface,wateringandscaffoldingetc

Providing&applyingacontinuouscementplaster ofsize50mmwide and15mmthickunderRCCpardi chajjaandaroundwindowopeningsatalllevels includingnecessaryscaffolding,stagingetc

Notes:

1)Theitemsgivenbelowshallbeasper'Paintingofthespecifications

2)ScaffoldingforPaintingshallbeofselfsupportingtype Holeswillnotbe allowed tobemadeinthemasonryorRCCworkforanchoringthescaffolding

3)ThebrandsofthePaintshallbespecifiedandreadymadepaintofrequired shadeshouldbeused

4)Thesurfaceshallbemadeperfectlysmoothbyrubbingwithsandpaperof differentgrades

5)Allholesandopenjointsshouldbefilledwithstrongputtyorwithamixtureof glueandplasterofparisandsmoothenedbyrubbingwithsandpaper

6)Insteelwork,allscales,dirt,suppliersdeliverymark,oil,greaseetcshallbe removedwithsandpaperbeforepainting Specialcareshallbetakenforcleaning thecorners

7)Eachcoatsshallbeallowedtodryupperfectlybeforethesucceedingcoatis laidoverit

8)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction

Providingandapplying3coatsoveracoatofprimer ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces,scaffoldingetc completeinall

Providingandapplying3coatsoveracoatofprimer,ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces

Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces,

Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces

Notes:

1)Theitemsgivenbelowshallbeasper'Flooring'ofthespecifications

2)Atleast6samplesforallfinishingitemsofwork fromdifferentapproved sourcesshallbesubmittedbeforestartingtheworkforapproval Architectin chargedecisionregardingtheshade,qualityandthesourceisfinal Alllike materialsofflooring,cladding,etctobefromsamebatchasperapprovedsample

3)Rateshallbeinclusiveofallexposedstone/tileedgestobechamfered,hand polishedandmouldedasdirected

4)Ratesforverticalcladdinginstoneofthicknessfrom6mmto25mmshallinclude exposedrightangularcornerjointsfinishedandedgespolishedandmouldedas perArchitect'sinstruction,withcutting6mmgroovesandalsoedgepreparationto suitcornerangles

5)Skirting/dado/cladding,becauseofvaryingheightwillbemeasuredandpaidon squaremetrebasisinsteadofonrunningmetrebasis

6)Therateforflooring/claddingshouldbeinclusiveofbedding/backcoatas specified Thethicknessofmortarbeddingorbackcoatspecifiedisminimum Thisthicknesswillvaryaccordingtothethicknessofflooringorcladdingmaterial soastosuitthespecifiedlevelorline TheContractorshallberesponsiblefor properbondingbetweenbackingcoat&masonryworkorRCCworkandhisrate shallbeinclusiveofprovidingandapplyingapprovedbondingagent

7)Forallverticalcladding,anapprovedchemicaladhesivefortilesasper manufacturer'sinstructionsshallbeusedandtheratesquotedshallbeinclusiveof thecostofthisadhesive forathickness3mmto4mm

8)Unlessotherwisespecified allsizestobeinmetricsystem

9)Scaffoldingforexternalcladdingshallbeofselfsupportingtype Holeswillnot beallowedtobemadeinthemasonryorRCCworkforanchoringthescaffolding

10)Therateforverticalcladdingshouldalsoincludetheworkonisolatedcolumns, chamfers,etc

11)Noseparatepaymentwillbemadeforprovidingandfixing,oddsizedtilesof anyshapeandsizetosuitconsultantrequirement

12)White/ColouredcementwithmatchingpigmentsorJohnsonBALgroutwith appropriatecolourshallbeprovidedbyContractorathiscost

13)TheContractorshallprovidesuitablesupportsforsupportingthecladdingtiles andremoveitonlyafterthetileshavefirmlyadheredtoitslocation

7
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units h4 plasterexternally (FirstFloor) h5* dripmould J PAINTING j1* (Internal-GroundFloor) j2 (Internal-FirstFloor) j3 (External-GroundFloor) j4 (External-GroundFloor) K FLOORING&PAVING&SKIRTING
complete 26572 280 -- 26572 SQMT
andcuringcomplete 4360 -- -- 4360 R MT
respects 197540 -- -- 197540 SQMT
scaffoldingetc
respects 79536 -- -- 79536 SQMT
completeinall
applyingprimer putty etc complete 61436 -- -- 61436 SQMT
applyingprimer,putty,etc complete 26572 -- -- 26572 SQMT

MEASUREMENT SHEET

14)Edgesofcladdingtilesfixedonthecornersofthecolumnsandwallsshouldbe polishedasperdirectiveofArchitect,orasindicatedinthedrawings

15)Themaximumthicknessofthepastepreparedbyusingtileadhesiveand appliedonthewallandcolumnsurfacesshouldnotbemorethan3mm Contractorshallhavenoextraclaimsonaccountofincreaseinthethicknessofthe pastebeyondmaximumthicknessasspecifiedaboveduetofaultyworkmanshipor anyotherreason

16)Mortarrequiredforbedding/backcoatshallbemixedmechanicallyinmortar mill Onlyriversandshallbeusedinthemortar

17)Allfixtures,electricalpoints,lightsetctobealightedwithtiling,groovesand pattern,flushwiththewallfaceasperdetailsanddrawings Amockupforthe sameshallbegotapprovedfromArchitect

18)Thecontractorsarerequiredtostudydrawingscarefullytounderstandfixing detailsofflooring,skirting,claddingetc,tokeeprequiredgroovesbetweendifferent finishesatdoorandwindowlocationsflooringandskirtingjunction,wallandceiling junctionetctomatchflushlinei e verticalplaneofwallandskirtingetc

19)Rateshallbeinclusiveofcostofscaffolding,grouting,curing,finalpolishingby non-slipwaxpolishandcleaningofsurfacesandalsodewatering&keeping surfacedryduringconstruction

20)Asample/mockupofflooring cladding etctobegotapprovedfrom Architect

21)Alladditionalgroovestobeprovidedinvertical horizontalanddirectionas shownindetaileddrawingsorasdirected

22)Tomakewallcladdingsurfaceandskirtingsurfaceflush,wallatskirtinglevel shallberequiredtorecessinsideasperfixingdetails Thenecessaryrecessesin RCCwalletcshallbetakenatthetimeofconstructionitself

23)Only43gradecementshallbeused

k1 shahabad stoneflooringforclassrooms

Providingandlaying25mmthickhandcutandmirrormachinepolished ,square300mmx300mmfinishedsizeandof approvedcolourandshadeinsmallerpatchesforrepairorinlargerareas including20mmthick1:2limemortarbeddingor1:6cementmortarbedding tobe compactedproperlybysuitablemethodasapprovedbytheArchitect,beforelaying shahabadstoneinposition Jointsfinishedwithneatcementslurry,widthofjoint shallbebetween10mmto150mmlayingasperdesign,including3coatsof machinepolishingafterlaying

k2 green kotahstoneflooring forplinthsandmidlanding,

Providingandlaying25mmthickhandcutandmirrormachinepolished square600mmx600mm finishedsizeandofapprovedcolourandshadeinsmallerpatchesforrepairorin largerareasincluding20mmthick1:2limemortarbeddingor1:6cementmortar bedding,tobecompactedproperlybysuitablemethodasapprovedbythe Architect,beforelayingKotahstoneinposition Jointsfinishedwithneatcement slurry widthofjointshallbebetween10mmto150mmlayingasperdesign including3coatsofmachinepolishingafterlaying,curing,cleaningcompleteas

5mmthickkotahstone300x300mm

Providingandfixing and10mm thickness(Santron)greycolourfor asdirectedincluding 15mmthickbackingcoatplastering1:4cementmortar,fixingwithadhesivesas

ofheight100mm mirror polishedandmachinecut20mmthickshahabadstone,andsizetomatchthe jointsinflooring,etccomplete

Providingandlayinginrequiredposition overconventional waterproofingtreatmentoratgroundleveloverPCCorIPSbaseofapproved colourandpatternon40mmthickbeddingof1:4cementmortarincludingneat

Providingandfixing25-32mmthick ofpolished jetblackgranitestoneofapprovedshape qualityandcolourincludingrough granitebase,samegranitebothsidepolishedverticalframes,cuttingholesof requiredsizesinappropriatelocationstoreceivesinkpipesetc horizontalshelves asdirectedbyArchitect Doublestonefasciaupto300mmskirting,edge moulding rounding/polishing fixinginthecementmortar1:3 curing cleaning withallvisibleedgesofgranitestonestobefinishedashalfroundorother specifiedmoulding,withheavygauge(18BWG)stainlesssteelsinkofavg 450mmx600mm,asapprovedofmakeslikeNirali,orCeramiclab(parryware/ Hindustanorapprovedequivalent)etccomplete

8
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units
curing
-- -- SQMT a)GroundFloor 47470 47470 SQMT b)FirstFloor 19030 19030 SQMT
cleaningcompleteasdirected
directed -- -- SQMT a)Groundfloor 29500 29500 SQMT b)FirstFloor 7640 7640 SQMT Sameasitemk2abovebutfor withmouldingfornosing,anti skidgroovesetc complete 1660 -- -- 1660 SQMT -Do-sameasinitemNok2abovebutfor
andmachinecut andsizetomatchthe jointsinflooring,etccomplete 13690 20535 SQ MT 9160 -- -- 9160 SQMT -Do-sameasinitemNok1abovebutfor
R MT/ SQ MT a)GroundFloor 30240 30240 b)FirstFloor 16660 16660
,mirrorpolished
cementfloat givingproperslopes compaction curingetc complete 6970 -- -- 6970 SQMT
840 -- -- 840 SQMT
k5 k6 skirting k7 chinamosaicflooring
anti-skidvitrifiedtilesof300mmx300mm
150
k3 risersandtreads k4 dadoofheight1500
k8 washbasinandkitchencounters k9 PaverBlocks
toiletblocksandkitchen

MEASUREMENT SHEET

Providingandlayingprecastconcreteshotblasted blackcolouredsquarepaving blocksofsize150x150x60mmthkeach(M:35gradeconcrete)ofapproved pattern,colourandmake(BasantBetonorapprovedequivalent)ofcompressive strengthof450kg/sqcm,homogeneouscross-section,granitechips,overa50mm thk(orasrequiredtoadjustlevelsonsite)layerofcleansandcushionincluding spreadingsand layingtheblockstotherequiredslope leveling compactingwith vibratorycompactor,fillingthejointswithdrysand,cleaningthesurfaceetc With alllabourandtransportationtositeandasperthedirectionsoftheArchitect

Providingandlaying40-60mm thk RoughGranite{shotblasted/flamefinished} Flooring for orasmentionedunderofsizes12x12m orasmentioned onacementmortarbeddingof1:6with10mmgroovebetweentheslabsand recessedby5mmandfinishedinrichcementslurry

Notes:

1)CarpentryandJoinery Timber Steelcasement AluminumDoorsWindows skylightsopenable,slidingwindows,rollingshuttersandpolycarbonatesheet, curtainwalls,etc

2)Forallaluminumworks,thecontractorshallsubmitshopdrawingforeachitem ofworkindicatingthesectionofaluminum,itsweightandjoinerydetailandtotal weightofwindow/door/partitionwallsetc Whereverpossiblerivetingshallbe resortedtoforconnection Alternativelyhotdippedgalvanizedpinheadedsheet metal/brass,screwscouldbeused Nomildsteelwithouthotdippedgalvanizing shallbeusedforanyfastenings,etc

3)TheratesshallnotbepaidseparatelyforAluminumsectionsusedonweight basis

4) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc

5)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal

6)Alljointsbetweencivilworkandaluminumframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractorscost

7)Ratesforrepairsaswellasprovidingandfixingofnewdoors,windows,sky light,rollingshutters,etc inthissectionshallbeinclusiveofalltheitemsof hardware/fittingsandnoextrashallbepaidtothecontractortowardsthecostof hardware/fittings

8)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including,fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:

9)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)

10)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand

11)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)

12)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized

13)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete

14)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect

15)BrassoxidizedBabylatches 75mmlongwith25mmx8mmthickboltcomplete withknob,Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal

16)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release

17)PlainMorticelocks6leversLatchBoltofGodrejmakeequivalentwithbrass bodyandchromeplatedflatplatetoedgeofdoorincludingfixingtotimberor aluminiumshutterframesetccomplete

18)Sameasaboveitem(16)butwithdeadlock

19) 3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)

20) Doorbufferwithrubber/PVCbushshutterorwallmounted

21)Providingandfixing andrepairrateswillalsobeinclusivealdrops,handles stopperetc allcomplete

D1-SingleleafhingedSunmicadoor

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing 6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor

9
Sr No. Description Quantity PLineArea/Perimeter Height/Width No Total Units
8680 -- -- 8680 SQMT
900 -- -- 900 SQMT
includingmouldedarchitraveetc complete 230 500 115 SQ MT D2-singleleafhingedwooddoorwithglasspanel
M
m1 m2
polishofapprovedcolourandmake
k10 ramps
DOORS,WINDOWSANDPARTITIONS

MEASUREMENT SHEET

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc

Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor

D4-3panelcollapsiblewoodendoorwithgrillweighing25kg /sqm asper detaileddrawingsanddesignincludingnecessaryanchoring,includingcleaning, sandblasting,threeormorecoatsofepoxypaintetc

D5-3panelcollapsiblewoodendoorwithgrillweighing25kg /sqm asper detaileddrawingsanddesignincludingnecessaryanchoring includingcleaning sandblasting,threeormorecoatsofepoxypaintetc

W2-AluminiumOpenablePanelsWindow

Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium heavysectionsJindalorequivalentmakeforwindows/ventilators,sidehungortop hungopenable/fixedcomprisingofouterframe(035kg/rm),shutterframe(050 kg/Rm) shutter--(040kg/Rm) mullionforouterframe(055kg/Rm) locking handlesandpullhandleforeachshutter,onepairSS frictionhingesforeach shutterand5mmthickclearfloatglassModiorwiredglassorequivalent with neoprene/rubbergasketwithhinges,lockingarrangementandwooden encasementwherevernecessaryincludingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan

W3-FixedwindowsGrills

i)Providing,fabricatingandfixinginpositionboxtype/windowgrills,weighing25 kg /sqm asperdetaileddrawingsanddesignincludingnecessaryanchoring, includingcleaning,sandblasting,threeormorecoatsofepoxypaintetc complete tothesatisfactionofArchitect

W5-Aluminiumopenable4panelslidingwindow

Providing fabricatingandfixinginpositioncolouranodisedextrudedaluminium slidingwindowsfabricatedoutofextrudedwindowsectionofheavy11/4"seriesof Jindal/orequivalentsections(ie pipes,framesandtracksetc)comprisingof lockingarrangement,55mmthickplainModiglassorequivalentincluding necessaryaccessoriessuchashandles withneoprene/rubbergasketwithhinges lockingarrangementandwoodenencasementwherevernecessaryincluding maskingofwindowsillsbeforecompletionofwork,demaskingaftercompletion, cleaning,ratetoincludecolouranodisingallaluminiumsectionstoathicknessof

Notes:

1)Thecontractorwillgivea10yearsguaranteeoftheworkundertakenon Rs100/-Stamppaperontheapprovedformatdulyregistered

2)Tenpercentamountofvalueofworkswillberetainedfortheperiodoffiveyears fromthedateofactualcompletionofthework,willbereleasedprogressivelyat fourpercentaftertwoyearssubjecttoattendinganyrectificationofdefectsand balanceamountsbytheendoffiveyears

3)Allworktobedonethroughspecialistwaterproofingandstructuralrepair agenciesshallbeundertakenonlyontheapprovaloftheArchitect

bottomRCCraftslabandsidesofRCCwallsof watertanks

Providingandapplying70mmto75mmthickproprietarybrandcementbased waterproofing(boxtype)for ,septictanks,effluenttreatmenttanks,etc including providingleak prooftreatmentby injectiongrouting toconcretemembersat10mcentresinboth directionsandalsoatallconstructionjoints,andprovidingandfixing20mmto 25mmthickroughShahabadstoneorotherapprovedstonetilessetin20mmthick

1:3waterproofcementmortarandfinishingthebylaying/plastering,with20-30 mmthickC:Min1:3withwaterproofcompound(Contractortogivecomplete specificationsforwaterproofingsystemheproposetocarryout)

10
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units
complete 230 2000 46 SQ MT D3-singleleafhingedsunmicadoor
polishofapprovedcolourandmake,includingmouldedarchitraveetc complete 150 1400 21 SQ MT
completetothesatisfaction ofArchitect etc complete 340 300 102 SQ MT
completetothesatisfaction ofArchitect,etc complete 420 600 252 SQ MT
Providingandfixingteakwoodwindowframesalongtheedgeof10mmthick WPCorientable4panellouveredwindow 220 400 88 SQ MT
W1-
20micronsetc completeasdirected 110 500 55 SQMT
etc complete 080 800 6 SQMT W4-Providingandfixingfrostedglass6mmthickforlouvered/glazedwindows 025 1500 375 SQMT
anodicfilmnotlessthan20micronsetc completeasdirected 220 2000 44 SQMT
104650 104650 SQMT m3 m4 m5 m6 m7 m8 m9 m10 N WATERPROOFING n1*

MEASUREMENT SHEET

Providingandlayingwaterproofingin in allpositionconsistingofspecialisedapprovedwaterproofingcompoundand materialasperspecificationswithallleadandlift

waterdrinkingareawithbricksbats

Providingandlayingcementbased laidinrequiredslopetodrainthewaterfor anyspanaftercleaningthe basesurfaceapplyingacoat ofcementslurry admixedwithapprovedwaterproofingcompoundandlayingthebrickbatson bottomlayerinC:M1:5admixedwithapprovedwaterproofingcompoundfilling uptohalfdepthofthebrickbats,curingthislayerfor3daysapplyingcementslurry overthislayerjointingofbrickbatswithC:M1:3admixedwithapproved waterproofcompoundandfinallytopfinishingwithaverage20mmthicklayersof cementmortaraddedwithjutefiberat1kgperbagincludingfinishingthesurface smoothwithcementslurryadmixedwithapprovedwaterproofingcompound

Providingandapplyingwaterproofingtreatmentoverchajjausingproprietary cementbasedsystemlikeIndiaWaterproofingusingbrickbatsof50mmormetal no2 averagethicknessoftreatment50mm finishedwithsmoothcementfinish withfalsetilemarks,includingbreaking/removingexistingwaterproofingand cartingawaythedebrisetc

Providingandfillingcementbasedtilejointsealingcompound(JohnsonBalGrout orequivalent)inbath/WC/toilet/flooringtilesincludingrakingoutoldloose

Providingandfixing shallbehoused approximately300mmabovechajjainamortarjointofadjoiningmasonrywall,this sheetctshallbeslopingoutwards Fasteningdown –Thesheets shallbe fastenedwiththebestSSorBrassscrews/boltsandleadwashersAllen’s,Fisher orotherapprovedfasteningsasdirectedbytheConservationArchitect Thelead sheetingshallbegoodmilledleadnotlessthan10Kg/Sqmbenttotheshape fastenedintothewall groove20mm,withbrass/sswallhookswithjointsatright

SECTION-IV: MISC

Notes:

1)Rateshallincludeminorcivilwork,scaffolding,electricalworks,dismantling, liasoningcost,steelitems,etc

2)Thequotedpriceshallbeinclusiveofcentralexciseduty,VAT,octroiandservice taxandallotherapplicabletaxes Thisquotationshallnotbesubjecttoprice variationcost

3)Thecontractorshallmakenecessaryarrangementstoprovidesuitablelockable weatherproofstoragespaceforthematerialsandshallalsostacktheexisting dismantledmaterialinasafesecureplaceforthedisposalofthemunicipal authorities

4)Thecontractorshallincludeinthequotation60monthsfreemaintenance,which willbecommencedfromthedateofcompletionofproject

5)Thecostshallbeinclusiveofallpreparatoryworkandnoextracostwillbe providedtowardsthisitem

7) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc

6)Forallworksinthissectionasspecifiedbytheconservationarchitect,the contractorshallsubmitshopdrawingforeachitemofworkindicatingthesections materials its joinerydetailetc Whereverpossiblewoodenpinsshallberesorted toforconnection Alternativelystainlesssteel/brass,screws/boltscouldbeused Noothernails/screwsshallbeusedforanyfastenings,etc

8)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal

9)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost FabricationandinstallationofInformationSignasspecifiedinthedrawings

Providingandfixingseatingaroundtreeasperdrawings Internaldiameterofthe seatingtobeconsideredas15m Seatmadeof150mmdiaSS pipe35mmthick andbackrestof50mmdiaSS pipe35mmthick Bothpipestobebent&grouted intothegroundateitherend Seat&backresttobeweldedtointermediateleg support,eachlegconsistingof2nos 'Z'shapedSS plate4mmthk

SECTION-V: ELECTRICAL

ThisitemisworkedoutbytheElectricalConsultant

Forthepurposeofthiscourseanapproximateamountisbudgeted

11
Sr. No Description Quantity PLineArea/Perimeter Height/Width No Total Units n2 WCandbathroomincludingBB coba n3 waterproofingtreatmenttoterraceand
n4 WaterProofingChajja n5 Tilejointfilling n6 LeadFlashing750mmoverChajja 1 a) signageboard 2 1 EARTHING
7290 7290 SQMT
6970 6970 SQMT
complete 550 550 SQMT
jointingmaterial,curingetc complete 112800 112800 SQMT
iflevelspermit orby75mmjointsof foldedlead 1100 1100 RUNNING M
anglestotheflowbyadripwithaproperlap
Providing&fixinginposition inaluminiumextrudedbrown anodizedsectionwithlettersinvinylonbothsidescoveredwithacrylicsheetand asperapprovedsamplebyArchitectfixingasdirected 100
40mmapart&connectedat4pointswithSS bolts&cylindricalspacers 200
spaced

MEASUREMENT SHEET

Supply,Installation,TestingandCommissioningofEarthingstationasperIS3043 consistingof40mmGI3000mmlongpipe suppliedwithfunnelattopincluding saltcharcoal,masonrychamber,testlinkbox,hardwareincludingexcavationand masonryworkwithcastironcoverforthechamber

Supply&Layingof followingsizesofstrips &wiresfromearthingchamber/Gridto theelectricalequipment&terminatingthesame Theportionofthestripunder groundshallbelaidatadepthof600mmandonsurfaceshallbefixedwith spacers&clamps&alsoonTray Excavation&allcivilworktobeincluded

25mmx3mmGI stripforDistributionBoard(FirstDistributionBoardinacluster ofDistributionBoards)

8SWGGI EarthingwireforLighting&PowerDistributionBoard

Supply,Installation,testing andcommissioningof3phaseenergymetersuitable forunbalanceloadandincludingnecessarycutoutandjumperwiresetccomplete aspersupplycompany'srequirement

Supply,Installation,testing andcommissioningofTPNMCB16A andincluding ncessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement

Supply,Installation,testing andcommissioningofTPNMCB40A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement

Supply,Installation,testing andcommissioningofTPNMCB32A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement

Supply&InstallationofstandardmanufacturersDistributionBoardforLighting It shallbeastandardBoardwithdoubledoor&suitableforrecess mounting&shall beasfollows Scopeincludesmountingarrangementincludingnecessarysteel hardwareetcWiresinDB tobeproperlydressedwithbuttontapeandwithlugs, labelsetc

Incomer40ATPNMCB-1No 40A,30mA,2P,RCBO-3NosOutgoing 6/10ASP MCB-24Nos

Supply,Installation,Testing&CommissioningofPVCArmouredCablefixedto walls,Ceilingswithclamps,spacerssaddlesorlaidinreadymadetrenchortiedto cablestraywithcableties,tagsetc asfollows 1100VgradeasperIS

Installation Testing&Commissioningofcables(onwalls trays) PVCinsulated 1100Vgrade,steelarmoredasperIS1554withlatestamendmentincluding spacers,saddles,tags, etcThecablesto beproperlydressed

4Cx16SqmmALAYFY

3Cx10SqmmALAYFY

4Cx10SqmmAYFY

3Cx4SqmmAYFY

3Cx6SqmmAYFY

3Cx25SqmmAYFY

TerminationofcableswithHeavydutySiemenstypeglands&lugs Lugsused shouldbeCopperforcoppercables&Aluminiumforaluminiumcable Scopeto includeallmaterial&labourincludingpropertools,Insulationtape

4Cx16SqmmALAYFY

3Cx10SqmmALAYFY

4Cx10SqmmAYFY

3Cx4SqmmAYFY

3Cx6SqmmAYFY

3Cx25SqmmAYFY

Pointwiringforlight,bellpoint ScopetoincludecircuitWiringforlighting&the lightswitchboardwithswitches&furtherwiringtolightpoints Theswitchboard shallberecessmounted/surfacemountedofGIstandardasperthesupplier The pointWiringshallconsistof3x15Sq mmcopperwire,PVCinsulated,1100V gradeinPVCconduit/PVCcasingcaping Thewires&conduitsshallrunfromthe switchboardtotheindividualpoint&circuitwiringshallbeof3x25mm2copper wirefromdistributionboardtothe switchboard Modularplatetypeswitchestobe used6ASwitchSocketonswitchboardtobeincludedInmajorityofthecasesthe lightsaregroupswitchedfromtheDistributionBoardinwhichcasethewireshall be3x25mm2 AllwiresshallbeFRLS

PrimaryLightPointwiringofaveragelengthupto5meterslengthofwire

PrimaryLightPointwiringofaveragelengthupto55to10meterslengthofwire

PrimaryLightPointwiringofaveragelengthupto105to15meterslengthofwire;

PrimaryLightPointwiringofaveragelengthupto155to20meterslengthofwire;

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto5metersof lengthofwire3x15sq mmwires

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto55to10 metersoflengthofwire3x15sq mmwires

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto105to15 metersoflengthofwire3x15sq mmwires

12
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units a 2 EARTHINGSTRIPS/CONDUCTOR a b 3 METER a b c d 4 DISTRIBUTIONBOARD a 5 CABLES&TERMINATIONS a b c d e f 6 TERMINATIONOFCABLE a b c d e f 7 POINTWIRING ai aii aiii aiv b.i bii biii
(LDB)

MEASUREMENT SHEET

SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto155to20 metersoflengthofwire3x15sq mmwires

FanpointwiringshallbesameasPrimarylightpointpointwithindividual controlWireofsize3x15sq mmsizeshallrunfromtheswitchboardtothefan pointthroughPVCconduit/PVCcasingcaping ThecircuitfromtheDBtothe switchboardshallbe3x25sq mmwiresSpaceforregulatortobeprovidedinthe switchboard Upto5Metersof lengthofwire

FanPointwiringwiringlength55to10meterlength

FanPointwiringwiringlength105to15meterlength

FanPointwiringwiringlength155to20meterlength

Exhaustfan/WallFanpointswiringshallbesameasPrimarylightpointwith individualcontrol&6Asocket&top@thefanpoint Wireofsize3x15mm2size shallrunfromtheSwitchBoardtothefanpointthroughconduit Thecircuitfrom theDB totheSwitchBoard with3x25mm2wire

Pointwiringfor6Ampswitchsocketpoint Scopetoincluderunningof3x25mm2 copperwire,PVCinsulated,1100VgradeinPVCconduit Wirestoberunfromthe PowerDistributionboardtotheIndividualsocketsupto4socketscanbeloopedon onecircuitWorkstationRawpowerAllwiresshallbeFRLSWiringlengthupto5

meters

6Asocketpointwiringlength55to10meters

6Asocketpointwiringlength105to15meters

6Asocketpointwiringlength155to20meters

Pointwiringfor6/16Amp switchsocketpoint ScopetoincludecircuitfromDB toindividualpoints Conduit,accessories&wireswith3x4mm2copperwiretobe laidfromDBtoindividualsocket TwosocketpercircuittobeconsideredAllwires shallbeFRLSWiringlengthupto5meters

6/16APointwiring55to10meterlengthofwire

6/16APointwiring105to15meterlengthofwire

6/16APointwiring155to20meterlengthofwire

6/16APointwiring205to25meterlengthofwire

Supply,Installation,Testing&Commissioning6Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections

Supply,Installation,Testing&Commissioning6/16Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections

Supply,Installation,Testing&Commissioningof20AReyrollPlugsocketwith3pin

MetalTop,inmetalboardwith20ASPMCB

Supply,Installation,Testing&Commissioningof225mmDia ExhaustFanwith connection

Providingandinstalling connectingandcommissioning32ATPNSFUwithHRC

Fuse

ProvidingandlayingTwopairTelephonecableinexistingconduit/casingcaping

Providingandinstallingoutlet fortelephonecable

Providingandinstallingcelingfan1200mmsweepwithfivestepselectronic regulator

Supply&InstallationoflightfixtureswithSigmaBallastincludinglamps,junction boxes,downrod/supports,hardwares rawlplugs,wires/cablesetc asrequired andconnectingittoswitchboards

SupplyandInstallationofPortableEmergencyLightonBatterysuitableforupto10 hours Installite/Canaramake Mountingarrangementforlamptobeincluded 1x18WBracketlight

WST71150withGI waterpipearm1mlongweldedtothecap

WFZ42250

WIF22228SGW

Liasoningchargeswithrespectiveauthoritiesforshiftingofpointofelectrical serviceandothers

Excavationinoutsidesoilincludingrefilling

Supplyinganderectingsteeltubulerpole1651x1397x1143mmthickwith 45x45x365mmthickand(56x27x27mm)respectively11mtrs LongasperIS 2713withtestcertificatefrommanufacturercompleteerecteddulypaintedwithtwo paintsofredoxideandtwocoatsofaluminiumpaintcompleteerectedinposition withMS baseplateof30x30x06cmsthickweldedatthebottomandsuitable polecaperactedwithsetscrewsorwieldedcompleteerectedCC foundationand plinthJunction/Loopingboxincluded

Note:Foritemnos 16,17and18,ratesshouldbeinclusiveofa

Supplyinganderectingcentrifugalwaterpump(Monoblock)withCI impler, primingfunelcockandcommonflangemountedonacommonshaftofinduction motorof400V3phaseAC supplyofminimum3H PMotorcapableof dischargingwater600to170litesperminutesat125to275meterstotalhead fromallclauseswithfoundationandwith50mmsuctionand50mmdelivery,water pumpshallbeconfirmingtoIS1520complete(Crompton/Kirloskar/Grundfosor anyotherequivalentmake)

13
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units biv ci cii ciii civ d ei eii eiii eiv 8(i) (ii) (iii) (iv) (v) 9a b c d e 10a b 11 12 LIGHTFIXTURESINCLUDINGCONNECTIONANDBULB a b c d e 13 14 15
comprehensivemaintenancefor60monthsbythevendor 16

MEASUREMENT SHEET

Waterlevelcontrollerwithnecessaryprobesforcontrollingmotorforcutoffwhen uppertankwaterlevelisfull,whenwaterlevelinthetankcomestopredetermined levelpumpshallstartautomatically When waterlevelinthesuctiontankisbelow thewaterlevel,thepumpshouldnotstart Alsopumpshouldnotrundry The controllershallhavemanual autoswitchesandselectionofpump Therateshall includenecessarywiringwithcopperwires

DOLStartersuitablefor3HPmotorincludingoverload

Providingandfixing25mmPVCconduits/Casingcapingincludingallfittings

SECTION-VI: PLUMBING

Note:

Allcataloguenos referredinvariousitemsofsanitaryfittingsareasperHindustan /ParrywareSanitarywareCataloguesandallfixturesareJaguarContinental series

Providingandfixingapproved'Indian make white/colouredglazedvitreous chinawarewallhungEuropeanwaterclosetcisternincluding-

a)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc

b)CIchairsupportsforthewatercloset

c)Whiteorcoloured solidplasticseat&cover veryheavyqualitywith rubber buffersfixedtotheclosetwithCPbrasspillarhinges

100mmdiaconnectorpipefromPtraptothejunctionofthesoilstackonexternal faceofbuilding

ProvidingandfixingapprovedISImarkedmakewhite/colouredglazed'vitreous chinawarewash'handbasincountertoporsuitableformountingbelow'counter comprising:

a)White/colouredglazedvitreouschinawareovalshapedwashbasin,size 570mmx425mmwithsupportingMSorCIbrackets

b)1No15mmCPbrasspillarcockwithallfittings

c)1No32mmCPcastbrassbottletrapwithextensionpiecetowall wallflange withrubberadopterwasteconnection

d)1NoheavyqualityCPbrassangularstopcock15mmsizewithCPbrassflexible connectorpipe Thesupportingbracketshallbeprovidedwith3coatsofapproved paintofapprovedshade

Providingandfixingvitreouswhite/colourchinawareurinalcomprising

a)Largeflatbackwallhungurinalsize250x330x460mm

b)flushingtankof10ltrssupplyingto3urinalswithallfittings

c)CPbrasschromiumplatedflushpipingfromflushvalvetourinalterminatedwith a15mmscrewedspreader

d)32mmdomeCPcastbrasswaste

e)32mmnbCPcastrunningtrapwithextensionpipetowall,wallflange,rubber adopterforwasteconnection

Providingandfixing15mmsizeCPbrassbibtapISImarkedheavyqualityonGI lineswithflangeandCPconnectorofapprovedmake

Providingandfixing25mmthickwhite/colouredgranitepartitionswithmachine cutedges,roundedexposedcornersfixedtowallbycuttingchasesandfixingin cementsandmortar1:4etc

ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareOrissawaterclosetcomprising:

a)Orissapansize580mmx440mmwithboxriminletwithPorStrapasrequired

b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc

ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted

Nos

Nos

14
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 17 18 19 A SANITARYSYSTEM 11 12 13 14 15 16 170 1.8 19 1 10 111 B WATERSUPPLYSYSTEM
800 800
Nos
800 800
1400 1400
600 600
Nos
700 700
Nos
600 600 Nos
700 700 Nos Size15mm
700 700 Nos
complete
Size750mmx600mmclearofwall Size1800mmx600mmclearofwall ProvidingandfixingheavyISImarkedmakeheavyqualityCPbrassconcealed typestopcockwithheavyqualitycastwallflange
100diaCI connectorpipefromPorStraptothejunctionofsoilstackonexternal faceofbuilding 700 700 Nos SupplyandfixingHindustanPilkingtonmakemirrors,6mmthickwithplainor
capsscrewedtorawlplugsembeddedinwall 400 400 Nos Supplyingsinglebowlstainlesssteelsinkofapprovedmakewithwastecoupling& requiredfittingsetc complete 100 100 Nos
bevelededge,8mmthickplywoodbacking,4NosCPbrassscrewswithCPbrass

MEASUREMENT SHEET

Providing,laying,fixingjointingwithscrewedjointsusingteflontapeGIpipes heavyqualityconformingtoIS1239includingallfittingssuchassockets unions reducers,longorshortbends,elbows,nipples,flanges,checknuts,clampsetc testingthepipesandspecialsandpaintingthepipesandfittingswithonecoatof approvedprimer&finishingcoatsallasperspecificationsForpipesinexposed conditions:

Providing,laying,fixingjointingwithscrewedjoints'C'classheavyGIpipes conformingtoIS1239includingallfittings,testing,paintingwithbitumasticpaint protectionwrappingwithHessienfacedpolyethylenetaping&paintingcompleteas perspecifications Forpipelineslaidbelowgroundlevelandlaidinchasesin walls Therateincludesexcavationandcuttingchasesinwallsandreinstatement)

Providing,fixingandtestingheavyqualitygunmetalorbrassballvalvewith screwedends20kgmclassonGIorcopperpipelines(Leader/ZOLOTOmake)

ProvidingandfixinginpositiontestedheavyqualityISImarkedfullwaygunmetal gatevalveofneworequivalentmakehavingbothendsscrewedfemale conformingtoIS778:1984etc complete

i)50mmdia

ii)40mmdia

iii)32mmdia

iv)25mmdia

v)20mmdia

vi)15mmdia

Providing,erecting,fixingandcommissioningPVCoverheadwatertank(BMC approved)includingmakingofproperplatformasperconsultant'sdirection,lifting oftanktoterracefloorlevel placingoftankonplatforminproperalignment makingofinlet/outletconnectionsasperbye-lawsetc complete

i)5000litrescapacity

ii)2000litrescapacity

iii)1000litrescapacity

Providing fixinggunmetalnonreturnvalveofapprovedquality 80mm 65mm 50mm 40mm 32mm

ProvidingandfixingapprovedISImarkedmakeCIflangedwatermetersdirect readingtypecalibratedinlitres&kilolitrestestedandapprovedbyMCGMwithdirt box(strainer)includingmakingnecessaryflangedjoints,testingetc complete 40mmsize 50mmsize

Constructingbrickmasonryvalve&meterchambersin230mmthickbrickmasonry incementmortar15usingfirstclassbricksconstructedoverabedof150mmthick cementconcrete1:2:4plasteringinsideoutsideandallexposedsurfacewith 20mmthickcementmortar13,finishing'insidewithafloatingcoatofneatcement providing&fixingCIframe&coversize weightmentionedbelowpaintingallCI itemswith3coatsofapprovedbitumasticpaintetc complete Chamber600x600mmclearinsidewith600x600CIframe&coverweightingnot lessthan72kgms Depthofchambernotexceeding1000mm

ProvidingStructuralsupportforpipelinesusingchannels,tees,angles,flats& platesfabricationbycuttingthreading&weldingifrequired,applyingonecoatof redoxideprimerandthreecoatsofsyntheticenamelpaint,includingnecessary boltsnuts washeretc asrequiredbytheEngineer-in-charge Theweightofthe supportshallbecalculatedonthebasisofcatalogueweightsofsectionsused (weightofbolts,nutsetc willnotbeconsidered)

Providing&fixingbrassfloatvalveswithbrassrodandcopperfloat suitableto withstandapressure2 kg/sqcm

50mmnb

15
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 21* 22* 23* 24* 25* 26* 27* 28* 29* 210* 15mmnb 20mmnb 25mmnb 32mmnb 40mmnb 50mmnb 65mmnb 80mmnb 100mmnb
15mm 20mm
32mm
25mm
80mm 65mm 50mm 40mm 32mm 25mm 20mm 15mm

MEASUREMENT SHEET

Excavationintrenchesforpipelinesofrequiredwidthanddepthasdirectedby Engineer-in-chargeincludingtrimmingbottomandsides,excavationforsockets includingrefillingwithselectedexcavatedmaterial(afterlayingofpipeline)in 200mmlayers,wateringconsolidationdisposalofsurplusearthwithin50metc complete

Inordinarysoil(forCIpipelineslaidoutsidethebuildingonly)depthnotexceeding

15m

-Do-insoftrock

ProvidingandfixingbestIndianmakeCPbrassairvalveswithisolationvalvefixed onGIlines

15mmnbairvalvewith15mmisolationvalve 20mmnbairvalvewith20mmisolationvalve

Providingconnectionstoequipments(Kitchen/Laundryetc includingprovisionof controlvalve runningjointwithunionetc complete

65mmconnections

50mmconnections

40mmconnections

32mmconnections

25mmconnections

20mmconnections

15mmconnections

SupplyingandinstallingBourdentypepressuregaugesrange0to20Kg/sqcm calibratedbothinpsiandkg/sqcm with10mmbrassgaugecocketc complete

Providingandfixingpipesleevesupto600mmlong cutfromheavyqualityMS pipesconformingtoIS1239or3589(dependingonsizeofpipewithMSflange conformingtotable13ofIS 6392onbothendsanda6mmpuddleflangeatthe centreofthesleeve,allflangesweldedtopipe,fixingthesleeveinpositionbytack weldingtoreinforcementetc complete

40mmnb

50mmnb

65mmnb

80mmnb

100mmnb

Providingandfixingcastiron traps of selfcleansing design with watersealnot lessthan50mmwith or without vent,including setting the trapin1:2:4cement concreteetc complete Thetrapshall be P' or S'type as required Trapwith 100mm inlet and100mmdiaoutlet

Asinitem31buttrapwith75mmoutlet

Asinitem31buttrapinPVC

Asinitem32butwithPVCtrap

Providingandfixingstainless steel gratingof 18 gaugethick,withcircular perforationofapprovedpatternoverCItraps Thegratingshallbeofsize100mmx 100mmorcircularof100mmdia(asdirected) and shallbesetin cement,sand mortar1:3etc complete

-Do-gratingofsize150mmx150mm

Providing, fixing, jointingand testingPVCWCpanconnectorofapprovedcolour with or withoutvent horn all as perrequirementsofEngineer-in-charge Size 100mmi/d-Length300mmto400mm

Supplying laying fixingjointing&testingheavyISImarkedcastiron spun soil pipes/centricastpipesincludingallfittingswithorwithoutinspectiondoors,vents, cowls at topetc jointing with leadcaulked joints all as perspecification and as directedbyEngineer-in-charge

150mmi/d 100mmi/d

75mmi/d

65mmi/d

50mmi/d

Providing, laying, jointing with screwed jointsusing teflon tape GI pipesof classTataorZenithconformingtoclassheavyofIS1239withallfittingstestingthe piping painting with 2coatsofbitumasticpaintwrapping with Hasseinfaced polyethylenetapeintwo layers and againpaintingwith2coatsofbitumastic paint Therateincludesforcuttingchasesinwall&floorsforembeddingthepipe andreinstatementofsurfacetooriginalconditions

16
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units
40mmnb
50mmi/d 40mmi/d 32mmi/d
211* 212* 213* 214* 215* C INTERNALDRAINAGESYSTEM 31* 32* 33* 34* 35* 36 37* 38* 39 ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted

MEASUREMENT SHEET

Constructingbrickmasonryinspectionchamberofsizeof900x450mmanddepth asmentionedinitw\esmbelowincludingexcavationupto requireddepth,layingof 100mmthickPCCfoundationbedin1:3:6mix,230mmthickbrickworkinCM1:3, 20mmthickplasteringofwallsinside&outsideasspecified makingofsmooth channel&haunchinCM1:2,150mmthickPCCcopingontop,fixingofCI manholecoverofNecomakeweighingnotlessthan75kg,backfilling,removalof surplusearthasspecifiedetc complete

i)Depthbetween045and060m

ii)Depthbetween060and100m

TOTALOFSECTION-VI

SECTION-VII: LANDSCAPINGANDGARDENING

PlantingofFloweringtreesonsoftsurface:

Diggingofpitforplantationoftreebyexcavatingthegroundintheearth/murum/ sandof10mx10mx10msize,removingexcavatedmaterialfromsite,filling RedHillEarth(033Cum),Cowdungmanure(033Cum)andgoodexcavated earthfrompit(033Cum),mixingofRedHillearthandcowdungmanureand plantationoftreesapling stakingoftreesapling preparationoftreebasin levelling,wateringandmaintainingfor30dayssftercompletionofplantationand replacementofcasualtiestill30days (Excludingcostoftheplant)

PlantingofFloweringtreesonhardsurface:

Diggingofpitforplantationoftreebyexcavatingthegroundintheconcrete/ masonary/asphaltof10mx10mx10msize,removingexcavatedmaterialfrom site fillingRedHillEarth(033Cum) Cowdungmanure(033Cum)andgood excavatedearthfrompit(033Cum),mixingofRedHillearthandcowdung manureandplantationoftreesapling,stakingoftreesapling,preparationoftree basin,levelling,wateringandmaintainingfor30dayssftercompletionofplantation andreplacementofcasualtiestill30days (Excludingcostoftheplant)

18
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 324* A* Developmentwork a1 a2 B* Providingplantsandtreesaplings: b1* b2* b3* b4* b5* b6* b7* b8* b9* b11* b12* b13*
000 -- -- 000 SQMT
000 -- -- 000 SQMT Plant1 1000 1000 Nos Plant2 1000 1000 Nos Plant3 1000 1000 Nos Plant4 1000 1000 Nos Plant5 1000 1000 Nos Plant6 1000 1000 Nos Plant7 1000 1000 Nos Plant8 1000 1000 Nos Plant9 1000 1000 Nos Plant10 1000 1000 Nos Plant11 1000 1000 Nos Plant12 1000 1000 Nos

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.