Hemodynamic Management

Page 1

VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT
VYGON

BEING EQUIPPED WITH AN EFFICIENT MONITOR IS

quality of these data.

To guarantee the doctor is prescribing upon data that really reflect the hemodynamic status of the patient, medical devices used on the patient must not degrade the reliability of the information displayed on

2

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

The signal is picked up on the patient by a medical device.

If the signal is unreliable, the monitor will receive altered information and results may be biased.

THE QUALITY OF CLINICAL DATA IS A CHALLENGE FOR THE HEMODYNAMIC DIAGNOSIS

SIGNAL MONITORING THERAPY

It is by observing the pathway of the patient’s clinical data that Vygon identified the moments when they are at risk of degradation throughout the chain. This of course to better limit those risks and help the practitioners to make the right choices in the hemodynamic management of critically ill patients.

Reading the monitor allows for deciding the therapy that needs to be administered to the patient.

SIGNAL MONITORING THERAPY

If the administration is not optimal, the patients may not receive the prescribed treatment. They will therefore not benefit fully from the decided therapy, inducing a new biased signal leading to a potential diagnosis error.

The signal is sent to the monitor which delivers hemodynamic information.

If the monitor is not performing well, the interpretation of the data may be wrong.

3

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

RELIABLE DATA RELEVANT DECISION

A SOLUTION RELYING ON 3 PILLARS

SIGNAL MONITORING THERAPY

These 3 pillars contribute together to the quality of the measures and build a consistent solution.

Each pillar needs the performance of the others to create a real value chain for hemodynamic management.

To offer this solution, Vygon combines its complementary competencies: clinical expertise and technologic know-how.

An unaltered signal, translated by a high-performance monitor for an optimal therapy.

A precise and reliable signal thanks to the high quality of the devices.

A therapy delivered optimally thanks to devices designed to answer each patient-specific need.

easy to operate easy to trust

High-performance monitoring thanks to easy-to-use devices giving the relevant information.

4
every single patient every special care

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

ACCURATE ANALYSIS NEEDS AN ACCURATE SIGNAL

Inaccurate measurement may cause inappropriate interventions

• Fluids or vasoactive/inotropic support

• Treatment of false hypertension causing a reduction in tissue perfusion

SIGNAL

In the operating room and ICU, the arterial signal is the starting point of efficient hemodynamic management of critically ill patients.

The quality and accuracy of the signal must be reliable to make the right diagnosis.

Vygon arterial range and especially leadercath arterial catheters provide the right solution to ensure an unaltered signal is reaching the monitor.

5

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

leadercath

THE VYGON ARTERIAL CATHETER FOR HEMODYNAMIC MANAGEMENT

RELIABILITY

AND

SERVING HEMODYNAMIC DIAGNOSIS

QUALITY

The combination of catheter material, catheter diameter, and catheter length delivers consistent pressure signal transmission even for extended dwell times, for all kinds of patients.

Catheter material: Pressureresistant polyethylene catheter material avoids damping of the pressure waveform.

The Seldinger technique makes arterial puncture easier, particularly in hypotensive patients with a weak peripheral pulse.

6

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

MONITORING

The critically ill patient’s vital signs are monitored continuously in the operating room and intensive care units. Hemodynamic monitoring is at the heart of this surveillance and is a crucial element to take into consideration in the diagnosis process and the related therapeutic decisions.

But today, not all critically ill patients are properly monitored because of complex and costly monitoring devices.

7
Vygon MostCareUp hemodynamic monitor is the simple, affordable, and clinically validated solution for efficient hemodynamic management for all the patients who need the closest attention.
CLEAR PRESCRIPTION NEEDS CLEAR MONITORING

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

Accurate arterial variables

• Dynamic e-filter

THE VYGON MONITORING SYSTEM FOR HEMODYNAMIC MANAGEMENT

EASE-OF-USE AND ACCURACY SERVING THERAPEUTIC DECISIONS

Thanks to its unique algorithm, MostcareUp is able to follow, in real time and from beat to beat, even the slightest hemodynamic variations in the patient. From the operating room to ICU, this advanced monitoring system adapts to a wide range of patient types and clinical conditions.

• PRAM patented algorithm

• Supported by +70 studies

Best quality/price ratio

• No disposable

• Unlimited use

• Made in Europe

EASY 3-step process

• Check

• Connect

• Monitor

Other unique features

• DO&CHECK function

• Specific variables (e.g. CCE)

• Pediatric use (>3kgs)

• HL7 compatible

• After-sales service

8

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

THERAPEUTIC EFFICACY NEEDS PATIENT

ADAPTED DEVICES

THERAPY

Having the right signal quality and an efficient monitor are key factors for a proper hemodynamic diagnosis of a critically ill patient. But is it enough to complete the whole process of hemodynamic management? If the prescribed drugs don’t reach the patient as per the prescription, the new signal sent to the monitor will not reflect the real reaction of the patient and may lead to diagnosis and therapeutic errors.

Vygon central venous catheters and infusion lines are the right tools for a safe and mastered infusion therapy, adapted to the specific needs of each patient.

9

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

multicath UP high flow

THE VYGON CENTRAL VENOUS CATHETER FOR HEMODYNAMIC

MANAGEMENT

INNOVATION AND KNOW-HOW SERVING FLUID MANAGEMENT

High flow lumen up to 400 ml/min

Safety accessories as a standard

Hemodynamic instability may require rapid infusion of a big volume of fluids. Multicath UP High flow central venous catheters have been designed to achieve rapid and safe high volume replacement therapy.

This unique catheter avoids the need for extra IV cannulation while preserving the capacity of drug infusion and blood sampling.

10

VYGON VALUE CHAIN FOR HEMODYNAMIC MANAGEMENT

vyline V

THE VYGON INFUSION LINE FOR HEMODYNAMIC MANAGEMENT

The combination of components of Vyline V lines builds the complete solution for a safe and mastered infusion of vasoactive drugs:

bionector Needleless connectors for a closed and safe system

Polyethylene line material for a linear and continuous flow

SIMPLICITY AND SAFETY SERVING INFUSION QUALITY

octopus double extension lines to manage the changeover far from the patient

Non return valves for a mastered multi-infusion set up

Coloured labels for an easy identification

Because of their specific properties (strict IV administration, short halflife, narrow therapeutic index), vasoactive drugs are risky and complex to infuse. Hemodynamic instability due to syringe changeover and complex infusion line setup is commonly observed in intensive care units.

11

FOR FURTHER INFORMATION, PLEASE CONTACT: questions@vygon.com The specification shown in this leaflet are for information only and are not, under any circumstances, of a contractual nature.

VYGON – 5, RUE ADELINE - 95440 ECOUEN - FRANCE

RECEPTION: +33 (0)1 39 92 63 63 – SERVICE CLIENTS FRANCE: +33 (0)1 39 92 63 81 EXPORT CUSTOMER SERVICE: +33 (0)1 39 92 64 15 www.vygon.com – www.hemodynamic-management.vygon.com – 

12/22DBCATH22630EV1

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.