4.2017 EMC från bricka till bricka

DEL 20

EMC & SKÄRMNING

ANDRA LÄCKAGEVÄGAR

The Relation between

Common mode effects in high speed serial links

IMMUNITY TESTING in Anechoic and Reverberation Chambers

TROUBLESHOOTING EMI (PART II, SUSCEPTIBILITY PROBLEMS)

SOME SIMPLE HINTS FOR

IDENTIFYING AND FIXING EMI TROUBLES + KALENDARIUM SID 6 + FÖRETAGSREGISTRET SID 36–39 + Ny el-standard SID 8 + ÖGAT PÅ SID 10–11 >>>

Complete EMC solutions from the market leader Contact us regarding your EMC application 08-605 19 00 or info.sweden@rohde-schwarz.com

www.electronic.nu – Electronic Environment online

1


Smart fortbildning på Electronic Environment 2018 25-26 april 2018, Kistamässan, Kista Science City VÄLKOMMEN TILL EE 2018! Electronic Environment är mötesplatsen för dig som vill hålla dig uppdaterad och fortsätta utbilda dig inom elektronikmiljö. Behovet av kompetens och nya resurser inom elektronindustrin har skapat en ökad efterfrågan på utbildningar och spetskompetens. Det tar vi fasta på och stöper om vårt tidigare konferensformat till ett renodlat utbildningsformat, med workshops och heldagsutbildningar inom fyra högaktuella teknikområden. Under EE 2018 har du möjlighet att medverka på följande heldagarsutbildningar: • EMC • ESD • Miljötålighet för elektronik • Internet of Things Missa heller inte tillfället att träffa branschkollegor, välkända företag, högskolor och branschorganisationer. Här kan du utbyta erfarenheter, diskutera idéer med näringsliv, högskolor och myndigheter. Anmälan Du anmäler ditt deltagande till utbildningarna på: www.electronic.nu.

För mer information:

www. electronic. nu


ELECTRONIC ENVIRONMENT 2018 – PARALLELLT MED S.E.E 2018 EE 2018 arrangeras parallellt med Nordens största mötesplats för den professionella elektronikindustrin, Scandinavian Electronic Event, på Kistamässan. Tillsammans ger det en oerhört spännande mötesplats med stora möjligheter för intressanta möten, för såväl kursdeltagare som utställare – en dynamisk träffpunkt för ny kunskap, nya kontakter och nya affärer. S.E.E 2018 arrangeras den 24-26 april. Kistamässan ligger centralt placerad i norra Stockholm och dess närhet till flygplatserna Arlanda och Bromma skapar gynnsamma förutsättningar även för internationella kontakter. På endast 12 minuter tar du dig med pendeltåg från Kistamässan till Stockholm C. Med närhet till E4:an, tunnelbana, pendeltåg och bussar tar man sig enkelt till och från mässan oavsett destination. I direkt anslutning till Kistamässan och i närområdet finns det gott om parkeringsplatser.


Electronic Environment #4.2017

Reflektioner

Dan Wallander Chefredaktör och ansvarig utgivare

I år blir det (h)jul..!

J

a, rubriksättaren är från Göteborg. Men det finns faktiskt en djupare innebörd med rubriken. Det handlar nämligen om Årets Julklapp, något som jag ägna några rader åt i denna spalt så här års. Det lackar nämligen med bestämda steg mot Jul, och precis som sedan 1998 utnämns varje år en Vinnarklapp av Handelns Utredningsinstitut (HUI). Och visst är det en elektronik-pryl – igen. UNDER DE SENASTE tio åren har elektroniken nämligen återfunnits i sju av Årets Julklappar. Den här gången är det el-cykeln som kniper utmärkelsen som den Hetaste Klappen av dem alla. HUI motiverar utnämningen bland annat med att el-cykeln speglar de svenska konsumenternas ökande klimatmedvetenhet, vilja att ta hand om sin hälsa samt att vara fri, flexibel och stundtals bekväm. Enligt HUI har el-cykeln dessutom en stor potential att på djupet förändra samhällets infrastruktur och människors beteenden. Och

sedan regeringen i årets höstbudget flaggade för införandet av en el-cykelpremie har intresset ökat ytterligare. Så, kanske nästa års Klapp blir hastighetsreglering, körkortstvång eller plåster. Vi får väl se. I APRIL ÄR DET DAGS för Electronic Environment 2018 på Kistamässan i Stockholm. EE 2018 kommer då att helt fokusera på kompetensutveckling, genom workshops och heldagarsutbildningar inom EMC, ESD, miljötålighet för elektronik och IoT. Ett allt större behov av kompetens- och resursförsörjning inom elektronikindustrin ställer allt högre krav på tillgängligheten avseende utbildningstillfällen och lokalitet. Detta tar vi fasta på och stöper om vårt tidigare konferensformat till ett renodlat utbildningsformat. Det betyder en stor möjlighet att utbilda sig, eftersom heldagarsutbildningarna arrangeras parallellt med Nordens största mötesplats för den professionella

elektronikindustrin, S.E.E 2018, och lämpligen kombinerar man utbildningen med ett besök på S.E.E. I DETTA NUMMER presenterar Miklos del 20 av artikelserien ”EMC från bricka till bricka” där vi nu har kommit fram till läckagevägar. Michel Mardiguian presenterar den andra delen av sin omfattande artikel om att identifiera och åtgärda EMI-problem. Mats Bäckström presenterar en artikel med titeln ”Immunity Testing in Anechoic and Reverberation Chambers”, och från Ingvar Karlsson kommer bidraget ”Common mode effects in high speed serial links”. SÅ, ETT FULLMATAT nummer, lämpligt att försjunka sig i lagom till glöggen och pepparkakorna. JAG ÖNSKAR ER alla en riktigt God Jul, och ett

Gott Nytt År!

SHIELDING TECHNOLOGY

Shielded secure meeting rooms

Turn key shielded and anechoic chambers

Shielded rooms for data security

Shielding materials for self-assembly: doors, windows, absorbers, ferrites, filters, gaskets and metalized textiles.

Shielded boxes for GSM, DECT, radio testing etc

EMC testing services in our own lab.

www.scratch.se

www.emp-tronic.se Electronic Environment Ges ut av Break a Story Communication AB Mässans gata 14 412 51 Göteborg Tel: 031-708 66 80 info@breakastory.se www.breakastory.se

4

HELSINGBORG Box 13060, SE-250 13 Helsingborg +46 42-23 50 60, info@emp-tronic.se

Adressändringar: info@justmedia.se Tekniska redaktörer: Peter Stenumgaard Miklos Steiner Michel Mardiguian Våra teknikredaktörer når du på info@justmedia.se

STOCKHOLM Centralvägen 3, SE-171 68 Solna +46 727-23 50 60

Ansvarig utgivare: Dan Wallander dan.wallander@justmedia.se Annonser: Evelina Karlsson evelina.karlsson@justmedia.se Dave Harvett daveharvett@btconnect.com

www.electronic.nu – Electronic Environment online

Omslagsfoto: Istock Tryck: Billes, Mölndal, 2017 Efterpublicering av redaktionellt material medges endast efter godkännande från respektive författare.


Electronic Environment #4.2017

Redaktörerna

Troubleshooting EMI

Some simple hints for identifying and fixing EMI troubles

Peter Stenumgaard

23 Ur innehållet

Miklos Steiner

4 Reflektioner 5 Redaktörerna 6 Konferenser, mässor och kurser 8 Ny el-standard 10 Ögat på EMC & skärmning – Andra läckagevägar 12 Teknikkrönikan – Peter Stenumgaard 13 Rapport från svenska IEEE EMC 14 The Relation between Immunity in Anechoic and Reverbation Chambers 18 Common mode effects in high speed serial links 22 Produktnytt 23 Troubleshooting EMI Some simple hints for identifying and fixing EMI troubles 30 Forskning 32 Noterat 34 Branschnytt 35 Författare i Electronic Environment 36 Företagsregister

Common mode effects in high speed serial links

Civilingenjör Teknisk Fysik och Elektroteknik (LiTH 1988) samt Tekn Dr. Radiosystemteknik (KTH 2001). Arbetade fram till 1995 som systemingenjör på SAAB Military Aircraft där han arbetade med elektromagnetiska störningars effekter på flygplanssystem. Detta inkluderade skydd mot exempelvis blixtträff, elektromagnetisk puls (EMP) samt High Power Microwaves (HPM). Han har varit adjungerad professor både på högskolan i Gävle och Linköpings universitet. Peter arbetar idag till vardags på FOI. Han var technical program chair för den internationella konferensen EMC Europe 2014 som då arrangerades av Just Event i Göteborg.

18

Miklos har elektromekaniker- högskoleutbildning för telekommunikation och elektronik i botten samt bred erfarenhet från bl a service och reparation av konsumentelektronik, konstruktion och projektledning av mikroprocessorstyrda printrar, prismärkningsautomater, industriella styrsystem och installationer. Miklos har sedan 1995 utbildat ett stort antal ingenjörer och andra på sina kurser inom EMC och är också författare till den populära EMC-artikelserien ”ÖGAT PÅ”, i tidningen Electronic Environment. Under många år var Miklos verksam som EMC-konsult, med rådgivning och provning för många återkommande kunder. Mångårig erfarenhet från utveckling av EMC-riktiga lösningar i dessa uppdrag har gett Miklos underlag, som han med trovärdighet kunnat föra vidare i sina råd, kurser och artiklar.

Michel Mardiguian Michel Mardiguian, IEEE Senior Member, graduated electrical engineer BSEE, MSEE, born in Paris, 1941. Started his EMC career in 1974 as the local IBM EMC specialist, having close ties with his US counterparts at IBM/ Kingston, USA. From 1976 to 80, he was also the French delegate to the CISPR. Working Grp on computer RFI, participating to what became CISPR 22, the root document for FCC 15-J and European EN55022. In 1980, he joined Don White Consultants (later re-named ICT) in Gainesville, Virginia, becoming Director of Training, then VP Engineering. He developed the market of EMC seminars, teaching himself more than 160 classes in the US and worldwide. Established since 1990 as a private consultant in France, teaching EMI / RFI / ESD classes and working on consulting tasks from EMC design to firefighting. One top involvment has been the EMC of the Channel Tunnel, with his British colleagues of Interference Technology International. He has authored 8 widely sold handbooks, two of them being translated in Japanese and Chinese, plus 2 books co-authored with Don White.

www.electronic.nu – Electronic Environment online

5


Electronic Environment #4.2017

Konferenser, mässor & kurser

Konferenser & mässor

Föreningsmöten

TEC Göteborg

Se respektive förenings hemsida:

25 januari, Eriksberg, Göteborg

IEEE

Electronic Environment 2018 25-26 april, Kistamässan, Stockholm www.electronic.nu

Network Centric Warfare 2018

www.ieee.se

Internet of Things, IoT, teknik och protokoll

1-2 februari, Rom, Italien

Nordiska ESD-rådet

IWCE 2018

www.esdnordic.com

15-17 maj, Stockholm www.stf.se

5-9 mars, Orlando, USA

SER

EMC Introduktion

SATELLITE 2018

www.ser.se

12-15 mars, Washington, USA

SNRV

EDI CON China 2018

www.radiovetenskap.kva.se

20-22 mars, Peking, Kina

SEES

Microwave & RF 2018

www.sees.se

E-utbildning www.justkompetens.se/elektronik

21-22 mars, Paris, Frankrike

Kurser

Element är Ellära

S.E.E Scandinavian Electronic Event

24-26 april, Kistamässan, Stockholm

Radioantenner & vågutbredning

Electronic Environment 2018

24-26 april, Stockholm www.stf.se

(Se mer under Kurser) 25-26 april, Kistamässan, Stockholm International Electrostatic Discharge Workshop (IEW)

14-18 maj, Oud-Turnhout, Belgien 2018 Joint IEEE EMC & APEMC

14-17 maj, Suntec City, Singapore TEC Linköping

29 maj, Saab Arena, Linköping

E-utbildning www.justkompetens.se/elektronik EMC: Störningskällor, störningsoffer och kopplingsvägar

E-utbildning www.justkompetens.se/elektronik

EMC – Heldagsutbildning

Electronic Environment 2018 25-26 april, Kistamässan, Stockholm www.electronic.nu

TIPSA OSS!

Electronic Environment 2018 25-26 april, Kistamässan, Stockholm www.electronic.nu

Vi tar tacksamt emot tips på kurser, föreningsmöten och konferenser om elsäkerhet, EMC (i vid bemärkelse), ESD, Ex, mekanisk, termisk och kemisk miljö samt angränsande områden. Publiceringen är kostnadsfri.

IoT – Heldagsutbildning

Sänd upplysningar till: info@justmedia.se.

ESD – Heldagsutbildning

Electronic Environment 2018 25-26 april, Kistamässan, Stockholm www.electronic.nu

6

Miljötålighet – heldagsutbildning

www.electronic.nu – Electronic Environment online

Tipsa oss gärna även om andras evenemang, såsom internationella konferenser!


See emission and immunity sources at components level! Using the EMC-Scanner during the early stages of design enables you to detect potential emission or immunity problems before they become integrated into the product and expensive to correct. See what an EMC scanner can do for you, visit our website www.detectus.com.

See it before you

it!

q +46 (0)280 41122 p +46 (0)280 41169

info@detectus.com www.detectus.com

S. Hantverkargatan 38B SE-782 34 Malung

www.electronic.nu – Electronic Environment online

7


Electronic Environment #4.2017

Ny el-standard Listan upptar standarder fastställda under december 2016 och januari och februari 2017 men bara dem som jag bedömt relevanta för era läsare. Standarderna är sorterade efter fastställelsedatum bakåt i tiden och inom varje datum sorterade efter nummer i beteckningen. För varje standard anges svensk beteckning, internationell motsvarighet (om sådan finns), europeisk motsvarighet (om sådan finns). Om den europeiska standarden innehåller ändringar i förhållande till den internationella anges detta. Dessutom anges svensk titel, engelsk titel, fastställelsedatum och teknisk kommitté inom SEK. För tillägg framgår vilken standard det ska användas tillsammans med men för nyutgåvor och standarder som på annat sätt ersätter en tidigare standard framgår inte vilken denna är eller när den planeras sluta gälla.

SS-EN 50155, utg 4:2017

SS-EN 61960-3, utg 1:2017

• EN 50155:2017 Järnvägstillämpningar - Elektronisk utrustning för rälsfordon

IEC 61960-3:2017 • EN 61960-3:2017 Laddningsbara celler och batterier med alkalisk eller annan icke syrabaserad elektrolyt - Laddningsbara litiumceller och litiumbatterier för bärbara tillämpningar - Del 3: Prismatiska och cylindriska celler.

Railway applications - Electronic equipment used on rolling stock SEK TK 9 Elutrustning för järnvägar och järnvägsfordon FASTSTÄLLELSEDATUM: 2017-11-23 FÖRTYDLIGANDEN: Kan delvis användas också för annan kvalificerad civil utrustning. Genomgripande uppdatering sedan förra utgåvan.

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications - Part 3: Prismatic and cylindrical lithium secondary cells and batteries made from them SEK TK 21 Laddningsbara batterier FASTSTÄLLELSEDATUM: 2017-11-23

SS-EN 60068-2-18, utg 2:2017 IEC 60068-2-18:2017 • EN 60068-2-18:2017 Miljötålighetsprovning - Del 2-18: Provningsmetoder - R: Vatten, med vägledning Environmental testing - Part 2-18: Tests - Tests R and guidance: Water SEK TK 104 Miljötålighet FASTSTÄLLELSEDATUM: 2017-10-18

SS-EN 62619, utg 1:2017 IEC 62619:2017 • EN 62619:2017 Laddningsbara celler och batterier med alkalisk eller annan icke syrabaserad elektrolyt - Säkerhetskrav på stora litiumceller och litiumbatterier för tillämpningar i industrin Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for large format secondary lithium cells and batteries for use in industrial applications

Elektromagnetisk kompatibilitet SS-EN 61000-4-11, utg 2:2004/A1:2017

SEK TK 21 Laddningsbara batterier

IEC 61000-4-11:2004/A1:2017 • EN 61000-4-11:2004/A1:2017 Elektromagnetisk kompatibilitet (EMC) - Del 4-11: Mät- och provningsmetoder - Provning av immunitet mot kortvariga spänningssänkningar, spänningsavbrottoch spänningsvariationer Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurementtechniques - Voltage dips, short interruptions and voltage variations immunity tests SEK TK EMC FASTSTÄLLELSEDATUM: 2017-10-18 FÖRTYDLIGANDEN: Innehåller en informativ bilaga som ger bakgrund till några av de krav som standarden ställer på den använda generatorn, bl a beträffande stig- och falltid.

FASTSTÄLLELSEDATUM: 2017-11-23

Omfattar batterier för både stationära och rörliga tillämpningar (t ex UPS, reservkraft, truckar, fartyg) men inte för drift av vägfordon. SS-EN 62920, utg 1:2017 IEC 62920:2017 • EN 62920:2017 Omriktare för solcellsanläggningar - EMC - Fordringar och provningsmetoder Photovoltaic power generating systems - EMC requirements and test methods for power conversion equipment

SS-EN 61951-1, utg 4:2017

SEK TK 82 Direktomvandling av solenergi till elenergi

IEC 61951-1:2017 • EN 61951-1:2017 Laddningsbara celler och batterier med alkalisk eller annan icke syrabaserad elektrolyt - Laddningsbara slutna celler och batterier för bärbara tillämpningar - Del 1: Nickel-kadmium

FASTSTÄLLELSEDATUM: 2017-11-23

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-cadmium SEK TK 21 Laddningsbara batterier FASTSTÄLLELSEDATUM: 2017-11-23

SS-EN 61951-2, utg 4:2017 IEC 61951-2:2017 • EN 61951-2:2017 Laddningsbara celler och batterier med alkalisk eller annan icke syrabaserad elektrolyt - Laddningsbara slutna celler och batterier för bärbara tillämpningar - Del 2: Nickel-metallhydrid Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride SEK TK 21 Laddningsbara batterier FASTSTÄLLELSEDATUM: 2017-11-23

8

Sammanställningen är ett urval av nya svenska standarder på det elektrotekniska området fastställda av SEK Svensk Elstandard de senaste tre månaderna. För kompletterande information: www.elstandard.se

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

Komponenter för kraftelektronik, EMC & RF/Mikrovåg

Batterier & batterihållare • EMC & Termiska material Induktiva komponenter • Kondensatorer • Nätaggregat • RF/Mikrovåg

Flexitron AB • Veddestadvägen 17 • 175 62 Järfälla • 08-732 85 60 • info@flexitron.se • www.flexitron.se

www.electronic.nu – Electronic Environment online

9


Electronic Environment #4.2017

Ögat på Vad alla bör känna till om EMC:

EMC från bricka till bricka, del 20

EMC & SKÄRMNING DEL 3: Andra läckagevägar EMC måste tas om hand i alla delar, såväl på elektrisk som på mekanisk systemnivå, och på alla nivåer i en utrustning på ett systematisk och planerat sätt. Denna gång tittar på anslutningdonens och anslutningskablarnas inverkan på EMC-skärmning.

D

et är relativt enkelt att uppnå goda EMC-egenskaper när man har att göra med enheter med relativt små dimensioner (t ex digitalklocka eller telefon.) Ofta är båda emissionsegenskaperna och tåligheten inom gällande gränsvärden. Det blir helt annorlunda när vi handskas med enheter med flera anslutande kablar. Små apparater och enheter saknar oftast effektiva ”antenner”, som kan koppla störningsfält till eller från enheten.

Lite antennteori Likt läckage från en avlång öppning bestäms av öppningens längd i förhållande till våglängden, kan en kabel agera som antenn, där kabelns fysiska längd relativt störningens våglängd är avgörande. En kabel, ledning eller vilken ledande struktur som helst vars längd är lika med eller större än halva våglängden är resonant på denna frekvens och förstärker signalen kraftigt. Effekten finns mer eller mindre påtagligt även i närheten av resonansfrekvensen. Vi brukar hänvisa till en tumregel som säger att när strukturdelarnas längd är större än en tiondels (ibland tjugondel) våglängd då börjar de bli effektiva antenner. Det är alltså svårare att hantera apparater med anslutande kablar.

10

Hantering av kablar och anslutningar

Anslutning av kabelskärm

Kablar kan hanteras på två olika sätt: skärma kablarna eller använd filter. Denna gång behandlar vi kabelskärmning.

Kabelskärmen är oftast en förlängning av apparatskärmen och utgör därmed en del av en totalskärm. Öppningar i en totalskärm innebär läckage: således måste vi ansluta kabelskärmen till apparatskärmen.

Kabelskärmning De flesta konstruktörer och installatörer av elektrisk utrustning är överens om, att skärmade kablar är ett bra sätt att åstadkomma EMC. Men många gånger har jag sett att det kastas stora pengar ”i sjön” på grund av en övertro på kabelskärmars effekter samt okunskap om dess rätta användning och utformning.

Zonindelning Elmiljözon definieras som en given volym med bestämd elmiljö, begränsad av en sluten yta, en zongräns. (Notera att denna yta kan vara en fiktiv, tänkt, yta!) Vid all slags EMC-konstruktion är det viktigt att tänka i elmiljözoner för att åstadkomma en balanserad skyddslösning. Zontänkandet gör det möjligt att lätt identifiera kopplingsvägar och -mekanismer. (Se tidigare artiklar.) Allmänt sett förlänger en skärmad kabel, ansluten till ett apparathölje av metall, apparatens interna elmiljözon ut i kabeln.

www.electronic.nu – Electronic Environment online

En del instruktioner är uppenbart felaktiga då de säger att man skall JORDA kabelskärmen! JORDA betyder i detta fall, att vi ansluter kabelskärmen till närmaste zontillhöriga skärm med möjligast lägsta impedans. Den i särklass oftast förekommande EMCfrågan är: ”ska man ansluta kabelskärmen i båda ändan eller bara i en ända (och i så fall vilken)?” En skärmad kabel, ansluten mellan två apparater med metallhölje binder ihop apparaternas skärmar. Ett avbrott i skärmen (bristfälligt eller ej ansluten kabelskärm) medför att de yttre och inre zonerna, och därmed de olika miljöerna, kopplas samman. (Figur 1.) Är kabelskärmen avsedd att vara ”länk” mellan två apparater ska kabelskärmen anslutas till apparaterna i båda ändarna för att behålla zongränsen hel och därmed erhålla god skärmning.


Electronic Environment #4.2017

Figur 1. Kabelskärmning.

Figur 2. Kopplingsimpedans för skärmad kabel.

Figur 3. Exempel: kopplingsimpedans.

Figur 4. Anslutning av kabelskärm.

Figur 5. Kabelskärmsanslutning.

Vikten av lågimpediv anslutning Skärmade kablars skärmningsegenskaper beskrivs med hjälp av kopplingsimpedans (Figur. 2). Där: I = ström på skärmens utsida I´= ström på skärmens insida ΔU = spänning mellan två punkter på skärmens insida Kopplingsimpedans Zt = ΔU/I [Ω/m] Kopplingsimpedansen anger i ohm/m förhållandet mellan störningsspänning, som genereras på skärmens insida, och störningsströmmen, som flyter på utsidan av kabelskärmen. Även det omvända gäller. Kopplingsimpedansen är ett mått på kabelns skärmningsegenskaper, är frekvensberoende och avhängigt av ma-

terial och utformning. Typiska värden är 1 – 10 milliohm/m och exempel visas i Figur 3. En EMC-riktig kabelskärmsanslutning för skärmning av högfrekvensfält utesluter s k ”piggtails”, eftersom anslutningsimpedansen blir för hög och totalt dominerande i den sammanlagda kopplingsimpedansen. Figur 4. Där: L ̴ 10 nH/cm U = 2π·fˑLˑI eller U = -di/dt Vi bör eftersträva noll ohm i anslutningsimpedans för kabelskärmen. Runtomanslutning med kabelförskruvning av metall ger låg anslutningsimpedans (Figur 4). Där: U = I * Σ Zt där Zt är en funktion av f; U = I * [Z t kabel * längd + Zt anslutning]

www.electronic.nu – Electronic Environment online

OBS: Zt är oberoende av antal ledare inuti skärmen! En trådanslutning har ca 2 ohm impedans (dvs inte kortslutning) vid en frekvens motsvarande en tusendel av våglängden på grund av trådens egeninduktans. Jämfört med kopplingsimpedansen 10 milliohm per meter så motsvarar en cm pigtail läckaget från 100 m kabel! Använd skärmande runtomslutande bakkåpa för bästa resultat! Ett oftast tillräckligt sätt är att ansluta med kabelklammor till ledande underlag, t ex en plåtskärm (Fig. 5).

Miklos Steiner info@justmedia.se

11


Electronic Environment #4.2017

Teknikkrönikan Några trender inom EMC och produktutveckling MED DEN SNABBA teknikutvecklingen inom många områden så möter pruduktutvecklare samtidigt nya EMC-utmaningar som måste hanteras. Användningen av avancerade beräkningsprogram och sofistikerade mätinstrument för att säkra EMC har därför ökat de senaste åren. Detta gäller dock i första hand för större företag som kan ta den kostnaden och samtidigt har den kompetens som krävs för att använda dessa verktyg och mätinstrument på ett effektivt sätt. Mindre aktörer som inte kan finansiera sådana verktyg och som själva inte har in-house kunnande inom EMC har som tidigare att välja på externa konsulter eller en egen beprövad trial-and-error metodik. EN ANNAN TREND är en ökad användning av färdiga komponentblock såsom radiomoduler och andra färdigutvecklade RF-moduler. Här är utmaningen att kunna integrera sådana delar utan att de för-

utsättningar som de färdiga modulerna är utvecklade för åsidosätts på ett sådant sätt att nya EMC-problem skapas. Då färdiga elektronikmoduler är utvecklade för att fungera EMC-mässigt inom vissa givna förutsättningar så visar erfarenheter att EMC problem uppstår när modulerna integreras i tillämpningar som inte uppfyller dessa förutsättningar. Exempel på sådana avsteg kan vara att man använder andra typer av antenner, andra arbetsfaktorer för pulsning, andra signalfrekvenser eller andra uteffekter än vad modulerna är utvecklade för.

ökar på marknaden så är det kostnadsbesparande att utnyttja sådana i så stor utsträckning som möjligt. Detta förutsätter dock att man har kunnande för att integrera sådana moduler utan att nya okontrollerade EMC-problem uppstår. En ökad användning av färdigutvecklade RF-moduler kan således innebära oförutsedda kostnader om oturen är framme.

SÅDANA AVSTEG KAN innebära att icke önskade blandprodukter av signaler uppstår eller att nya signaler skapas av olinjära fenomen. En ytterligare trend som genererar nya EMC-problem är att somliga produktutvecklare integrerar komponentmoduler utanför sitt eget kunskapsområde. Då mängden färdigutvecklade moduler

Peter Stenumgaard info@justmedia.se

Hej, det är vi som är Proxitron! Vi kan bli din leverantör av utrustning och service inom EMC, elsäkerhet och miljötålighet.

Rickard Elf 0141-20 96 53 rickard@proxitron.se

Kontakta oss redan idag! Vi diskuterar gärna dina specifika servicebehov, kontakta oss för ett förslag eller ett kostnadsfritt besök.

Jonas Johansson 0141-20 96 55 jonas@proxitron.se

Proxitron AB – 0141-580 00 – info@proxitron.se – www.proxitron.se

12

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

Information från svenska IEEE EMC

EMC Europe 2018 THE ORGANIZERS of leading International Symposium on Electromagnetic Compatibility in Europe are very pleased to invite and encourage all those working in the area of Electromagnetic compatibility to Amsterdam to participate this prestigious event. Authors are invited to submit original papers on their latest research results focusing on all EMC aspects. The symposium gives the unique opportunity to present the progress and results of your work and to exchange ideas, discuss different point of view and share experiences with colleagues involved in EMC. Reviewed and accepted papers which will be presented in oral or poster sessions as well as will be submitted

for publication in IEEE Xplore. EMC Europe 2018 will be held at the ‘de Beurs van Berlage Conference Centre’, in the middle of Amsterdam from August 27 till August 30. Important dates: – Proposals for special sessions deadline: 1 January, 2018 – Paper submission deadline: 15 February, 2018 – Proposals for workshops, tutorials, short courses: 15 March, 2018 – Notification of acceptance: 15 April, 2018 – Final Paper Submissions: 15 May, 2018

JAG SITTER ÅTERIGEN och skriver på en spalt på ett tåg hem från Stockholm. Den här gångenefter att ha vi idag genomfört föreningens årsmöte med ett antal intressanta presentationer på temat RED. Förhoppningsvis så rätades en del frågetecken ut för deltagarna. RED har inneburit en stor förändring för många tillverkare av utrustning och harmoniseringen av standarder för RED ligger dessutom ordentligt efter. Föredragshållarna fick många frågor från deltagarna och tiden i programmet som från början kändes väl tilltaget blev till slut ganska pressat. Men jag hoppas att deltagarna var nöjda och presentationerna ligger när ni läser detta förhoppningsvis under sites.ieee.org/sweden. Klicka er fram via ”Chapter & Affinities” till ”EMC” och därefter ”EMC Chapter Archive”. Årsmötet förlöpte med sedvanligt lugn och sittande styrelse återvaldes för ytterligare ett år. Vi tackar för detta förtroende. En utmaning för oss är att vända på den vikande medlemstrenden. Jag deltog i en IEEE Chairman Workshop inom IEEE Sverige i oktober och en stor skillnad för oss inom IEEE EMC framstod för mig väldigt tydligt: Flera av de andra sektionerna ser sin huvudsakliga rekryteringsbas bland studenter och doktorander inom respektive område. Det finns trots allt en del doktorander inom områden som datorteknik, halvledarkomponenter och antenner. Men om vi inom EMC-sektionen endast skulle ha rekryterat inom gruppen ”EMC-doktorander i Sverige” så skulle vi ha tynat bort för länge sen. (Jag tror dessutom att alla dessa redan är medlemmar.) Det självklara svaret är ju att vi behöver locka medlemmar från andra kategorier också, men ett annat svar är att arbeta för att öka statusen för EMC som ämne på våra universitet och högskolor. Även andra delar av IEEE Sverige ser detta som en väg att öka inte bara medlemsantalet utan även ingenjörsyrkets status. En ljuspunkt när det gäller EMC-utbildningar är förresten att det nyligen har publicerats en ny lärobok inom EMC vilken dessutom är skriven på svenska. När hände det senast?

For detailed information download the First Call for Papers at www.emceurope2018.org.

Christer Karlsson Ordf. Swedish Chapter IEEE EMC

NYHET

CUSTOMIZED EMC-SOLUTIONS KAMIC EMC have more than 30 years of experience, regarding developing and installation of units and products within the electrical environmental area. We are today helping a number of hundreds individual customers and bigger companies with our knowledge in questions related to EMC and improved electrical environment. Welcome to us - we will guide you to your particular customized solution.

www.electronic.nu – Electronic Environment online

KAMIC Components Tel: + 46 (0)54-57 01 20, www.kamicemc.com

13


Electronic Environment #4.2017

The Relation between Immunity Testing in Anechoic and Reverberation Chambers A Review

14

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

The problem of relating the outcome of a susceptibility or immunity test in a reverberation chamber (RC) to free-space conditions was identified and addressed early [1]. In a RC the equipment under test (EUT) can be regarded as being simultaneously irradiated by plane waves coming from many directions [2]. By rotating a stirrer located inside the chamber the boundary conditions can be changed, leading to statistically independent field conditions (also other methods can be used for this purpose, see e.g. [3]). In that way the stress on the EUT will be varied. The concept of statistical isotropy, sometimes used for the RC, means that the ensemble average of the signal levels induced in an antenna (or in a EUT) will be independent of its directional properties. The fact that the variations in directivity and polarization are averaged out in a RC indicates that an immunity test carried out in a RC might be less severe than a test carried out in an Anechoic Chamber (AC), at least if the AC test comprises the angles of incidence and polarizations causing the maximum stress on the EUT. Of course, the opposite may also be true, i.e. that the immunity test in an AC might be less severe than a test in a RC. This happens if the angles of incidence and polarizations used in the test correspond to a weak coupling to the EUT.

Reverberation Chamber Basics A reverberation chamber is a highly conductive, electrically large, shielded cavity normally equipped with one or several stirrers to provide a statistically uniform and statistically isotropic field (ensemble averages) [4]. The field pattern consists of a standing wave pattern. The peaks and nulls are moved around by use of the stirrer, thus creating a statistically isotropic environment. Some advantages with reverberation chambers are: • High test field levels for moderate input power (of the order of kV/m for 100 W input). • Short testing time, i.e. cost-effective testing. • No rotation of the equipment under test (EUT) is required. • The location of the EUT is not critical (the distance from walls should be at least λ ⁄4). • Good repeatability between tests occasions and between different chambers. • Good simulation of the real electromagnetic environment for a EUT which operates in an overmoded cavity such as an electrically large avionics bay. • Absorbers are normally not required. • The statistical properties of the RC electromagnetic field are well known, thus the method uncertainty of a test can easily be calculated. • Provides electromagnetic isolation from the external environment. The reverberation chamber also has some disadvantages: 0 High lowest usable frequency (LUF), around a few hundred MHz for a 5 x 3 x 3 m3 chamber. 0 Problems using short pulses in testing due to the chamber’s high quality factor Q. (τ=Q⁄2πf). 0 Loss of information regarding polarisation (p) and directional (D) properties of the EUT. 0 Difficult to relate test results, when necessary, to free space conditions. The last point, i.e. if and how we can relate the stress a EUT feels in a (statistically) isotropic environment to that induced by a plane wave, will be treated below.

In Eq. (2) the averages (indicated by the brackets) are taken over all angles and polarizations.

Relation between AC and RC test environments – measurement of shielding effectiveness We start by making a comparison of a measurement of shielding effectiveness (SE) in the two environments since this more straightforward than comparing the results of an immunity test. For convenience, since the goal is to compare a SE measurement in the two environments, we use an ad hoc definition of SE in terms of the receiving cross section of the field probe located inside the equipment under test (EUT), related to the magnitude of the external field irradiating the EUT. We consider a EUT, equipped with an internal field sensor, as a receiving antenna. Furthermore, we assume that the measurement in the RC is made using an ensemble average of many statistically independent stirrer positions, i.e. the measured result corresponds to (almost) perfect isotropic conditions. In the RC the power received by the sensor inside the EUT is given by, cf. Eq. (2):

Relation between AC and RC Test Environments An immunity test in an isotropic environment may be either more or less severe than a test in a plane wave environment. Basically, this can be understood by considering the receiving cross section of an antenna. At plane wave conditions it holds: www.electronic.nu – Electronic Environment online

15


Electronic Environment #4.2017

where Pr,CalAntenna) is the power received by a lossless and impedance matched calibration antenna, ET is the total electric field strength. The averages are taken over all stirrer positions used in the test. In a corresponding measurement of SE in the AC, i.e. using the same sensor at the same location inside the EUT, we get:

where SAC is the power density of the incident plane wave. By equating the power densities, i.e. S SC= SAC , we get, cf. [5]:

Relation between AC and RC test environments – immunity testing In an immunity test the relation between the two environments becomes more complicated. One reason is that the immunity test parameter in a RC is given by the maximum field strength. Another reason is that different definitions on the RC test field strength lead to different relations [5]. Both the total, |ET,Max| , and a rectangular component, |E R,Max|, of the electric field are used in different standards. For the power received by a critical component inside the EUT one can show that:

Research Agency (FOI). Field probes were mounted inside each device to simulate the outcome of an immunity test, using |E R,Max|=|E AC |. The results show that, for typical test procedures, the expected level of under-testing were similar in the two environments, see Figure 1. The level of under-testing, in the figure called Apparent Error Bias, is defined as the deviation from an ideal immunity test in an AC, i.e. in which case the true Pr,EUT,AC,Max is attained. The expected Apparent Directivity equals 2DMax. The expected Error Bias in the reverberation chamber, cf. above, equals 3⁄2DMax. As can be seen in the figure, this corresponds well to the measured results.

Figure 1a. Comparison between

Figure 1b. One of the test objects in

measurement in anechoic and reverberation chamber (see text). Etest = |EAC | = |ER,Max|

FOI’s anechoic chamber (left) an in FOI’s reverberation chamber (right). Photos from FOI.

A Remaining Issue The review above concerns the stress picked up by a critical component inside the EUT. An analysis becomes more complicated if there are several critical components and, e.g., if a malfunction of an equipment requires a simultaneous malfunction of several critical components.

References

[1]. J. L. Bean and R. A. Hall, “Electromagnetic Susceptibility Measurements Using a Mode-stirred Chamber,” in Proc. of 1978 IEEE Int. Symp. on EMC, Atlanta, USA. [2]. D. A. Hill, “Plane Wave Integral Representation for Fields in Reverberation Chambers,” IEEE Trans. on EMC, Vol. 40, No. 3, August 1998, pp. 209-216. [3]. M. Bäckström, O. Lundén and P.-S. Kildal, “Reverberation Chambers for EMC Susceptibility and Emission Analyses”, Review of Radio Science 1999-2002, Chapter 19, Wiley-Interscience, John Wiley &Sons, Inc., New York, 2002. [4]. IEC 61000-4-21, ”Electromagnetic Compatibility (EMC). Part 4-21: Testing and measurement techniques – Reverberation chamber test methods”. www.iec. ch . [5]. J. M. Ladbury, G. H. Koepke, “Reverberation Chamber Relationships: Corrections and Improvements or Three Wrongs Can (almost) Make a Right”, 1999 IEEE Int. Symp. on EMC, Seattle, USA. [6]. G. J. Freyer, M. Bäckström, “Impact of Equipment Response Characteristics on Anechoic and Reverberation Chamber Test Results”, EMC Europe, 9 – 13 Obviously, the strong dependency on N when choosing |ET,Max| as the September 2002, Sorrento, Italy. test field strength may pose problems since the relation between the two environments becomes quite intricate, while this in practice is not the [7]. O. Lundén and M. Bäckström, “Pulsed Power 3 GHz feasibility study for a 36.7 m3 Mode Stirred Reverberation Chamber”, 2007 IEEE Int. Symp. on EMC, case for |E R,Max|. A discussion on definition of test field strength can e.g. July 8-13 2007, Hawaii, USA. be found in [7]. [8]. M. Bäckström, J. Lorén, G. Eriksson and H.-J. Åsander, “Microwave Coupling into a Generic Object. Properties of Measured angular Receiving Pattern and Eq. (8) points out the risk for under-testing in a RC, compared to a test its Significance for Testing”. 2001 IEEE International Symposium on Electroin an AC. However, the maximum stress level in the AC is in practice magnetic Compatibility, Montreal, Canada.

never attained since that would either require knowledge beforehand of the worst angle of incidence and polarization, which in general is impossible since it varies with frequency [8, 6], or that a huge number of aspect angles and polarizations must be used in the test. In [6] results are presented from coupling measurements in RC and AC made between 0.5 and 18 GHz on real equipment such as avionic boxes, a missile and an army radio. All measurements were carried out at the Swedish Defence

16

Mats Bäckström

www.electronic.nu – Electronic Environment online

Adj. Professor, Royal Institute of Technology (KTH) Saab Aeronautics


Electronic Environment #4.2017

EMC- OCH KOMMUNIKATIONSLABBET AWITAR Nu hĂĽller en ny världsledande test- och utvecklingsanläggning fĂśr trĂĽdlĂśsa kommunikationssystem och EMC pĂĽ att färdigställas pĂĽ RISE i BorĂĽs. Ă–ppnar fĂśr kunder i januari Awitar är designat fĂśr att mĂśta framtidens tekniker och krav och blir en viktig kugge i utvecklingen av framtidens fordon. En kontrollerbar och repeterbar elektromagnetisk miljĂś fĂśr provning och forskning som klarar stora fordon, maskiner och utrustningar. Läs mer pĂĽ http://www.awitar.se RISE – SVERIGES FORSKNINGSINSTITUT. Innventia, SP och Swedish ICT har gĂĽtt samman i RISE fĂśr att bli en starkare forsknings- och innovationspartner. I internationell samverkan med akademi, näringsliv och offentlig sektor bidrar vi till ett konkurrenskraftigt näringsliv och ett hĂĽllbart samhälle. RISE 2 200 medarbetare driver och stĂśder alla typer av innovationsprocesser. Vi erbjuder ett 100-tal test- och demonstrationsmiljĂśer fĂśr framtidssäkra produkter, tekniker och tjänster. RISE Research Institutes of Sweden ägs av svenska staten. www.ri.se

(14 #.. ;174 X *'4/#. #0& 5'#.+0) 51.76+105

-ROH[ $% 9lVWHUYLNVYlJHQ 9lUPG| 7HOHIRQ )D[ PDLO#MROH[ VH ZZZ MROH[ VH

www.electronic.nu – Electronic Environment online

17


Electronic E Electronic Environment #4.2017 nvironment #1.2017

Common mode effects in high speed serial links Abstract. In production of printed circuit boards (PCB) signal skew will be introduced in differential traces due to the weave effect. A skew that will vary from PCB to PCB. This signal skew generates mode conversion that together with poor common mode properties, along the high-speed channel, will degrade the system performance. For example, might the skew effect give a crosstalk much higher than the pure differential crosstalk. If the poor common mode properties in the channel are high and the skew can be expected to be high enough, the channel performance will be affected. Some PCB’s, with right combination of skew, might fail with too high bit error rate (BER) and other PCB’s will work.

18

www.electronic.nu – Electronic Environment online


Electronic Environment #2.2017

I. Introduction In high speed serial links are often components as connectors and via structures included. Such components and structures might have poor common mode properties. The poor common mode properties will not influence the differential signal as long as there is no common mode signal generated along the channel but influence if common mode signals are introduced. Signal skew is a large source of mode conversion to generate common mode signals in the channel. This common mode signal might have a large impact on the performance due to the poor common mode properties in the channel. This paper will discuss mode conversion, coupling mechanism and its impact on the performance.

II. Skew and mode conversion Mode conversion can be generated by several sources. Sources as signal skew, impedance mismatch, geometric differences in traces and stackup, non-symmetrical driven signals out from a transmitter, mismatch in transmitter and/or receiver termination impedance, imbalance in placement of ground vias around a differential pair via, imbalance in the signal path trough a connector etc. But normal will the skew generate the highest mode conversion. All other mode conversion is normally small compare to skew in high speed links.

Fig. 2 shows the differential insertion loss (IL) after the skew. With a skew of 25% of the bit length, approximately 10 ps in a 25G link, gives 0.7 dB in IL at half baud rate. But with a skew equal to one bit will create very large IL, in theory infinitely large, at half baud rate. With a skew of one bit and a transmitted data patter of 1.0.1.0.1.0… will not pass the link as a differential signal, it will show up as a DC-signal, a common mode signal, at the receiver. This does not mean that a channel with a skew equal to one bit or more will not function. The decision feedback equalizer (DFE) [1], in the receiver can, to a certain extent, reshape the signal to a useful signal pattern. For example, in a link with a one bit skew and the n-channel lag the p-channel. If now the DFE cancel out the contribution from the n-channel at each sampling point. Then will the receiver only see the p-channel with, for this example, is the bit pattern 1.0.1.0.1.0… This handling of the skew, in DFE, works only for the part of the lag pulse that is within the DFE working range. The signal will however suffer from extra losses, the signal will be approximately half in amplitude with one bit skew, approximately 6 dB extra loss, compare to a channel without skew.

Fig. 3. Increase in EYE closing after DFE verses signal skew

Fig. 1. Mode conversion caused by skew

Fig. 1 shows mode conversion caused by skew in the coupled transmission line. The transmission line is a stripline with equal propagation velocity for differential mode and common mode signals. On the x-axes is f/ fb scaled where f is the frequency and fb is the baud rate. On the y-axes is the amplitude in dB. With a skew of one bit will all off the differential signal be converted into common mode at half baud rate.

Fig. 3 shows the increase in EYE closing after DFE verses skew length. The link, in this case, has an IL of 20 dB at half baud rate and the graph shows the extra introduced losses, caused by the skew, after the DFE. With a skew of approximately one bit or more the increase in losses is about 6 dB. This type of losses will, in many cases, have rather low influence on the noise in the channel if we exclude crosstalk noise. But with margin for the extra losses and the increase in noise, caused by the skew, a channel with skew of one bit or more will work. Mode conversion converts, for example, parts of the differential signal into common mode signal. If this common mode signal reaches the receiver the receiver can normally handle this common mode signal without too high disturbance. The mode conversion in the receiver is normally rather low.

III. Skew combined with crosstalk

Fig. 2. Differential IL caused by skew

In the section II it was shown that common mode effects caused by skew will, in many cases, be of no problem, the DFE take care of the skew effects. Often will the common mode effects be ignored or add little attention to in the design process. With low attention on common mode properties often large or very large common mode crosstalk and common mode impedance mismatch can be observed in channels. It’s rather common to see plus 20 dB of higher common mode crosstalk compare to differential mode crosstalk in connectors, via structures etc. So, for example if there are a skew, on an aggressor line, in front of a connector, and the connector suffer from high common mode crosstalk then will the victim channel get a high common mode crosstalk signal. As the receiver is rather insensitive to common mode signal this common mode crosstalk signal will normally be of no problem. If we now have two sections with mode conversion in the link one on the aggressor channel in front of the connector and one on the victim channel after the connector, see Fig. 4.

www.electronic.nu – Electronic Environment online

19


Electronic Environment #4.2017 Spatial shifted differential pairs to minimize differential crosstalk; Sometimes one sees recommendation to spatial shift traces to minimize differential crosstalk or to place vias and pins in an orthogonal configuration. Fig. 5 shows two examples of this type of arrangement. Both have low differential crosstalk but high common mode crosstalk. If for example the shifted differential pairs are used in a PCB layout and the length of the coupled section is 10 mm. The differential mode crosstalk will be low but the common mode crosstalk will be very high. Fig. 6 shows the differential near end crosstalk, NEXT, with 40 mm traces between the aggressor and the coupling section and 40 mm traces between the coupling section and the receiver. The skew, of 10 ps or 20 ps, are placed equally on both the aggressor side and on the receiver side. The differential crosstalk, at close to half baud rate, increase with almost 24 dB with 10 ps of skew and almost 30 dB with 20 ps of skew compare to the situation with no skew. For such layout, for high speed links, will reduce the operational margin for a system when skew is introduced. Some connectors use this shift arrangement of pins inside the connector to minimize the differential crosstalk. The connector will then suffer from very high common mode crosstalk.

Fig. 4. Link with skew and common mode crosstalk

In this case will the signal convert to common mode in the aggressor skew part and feed the connector with common mode signal. This common mode signal will leak into the victim channel and at the skew part in the victim channel, after the connector, will this common mode signal convert back to differential mode and show up as a differential crosstalk at the receiver. A differential crosstalk, coupled as common mode crosstalk, added to the pure differential crosstalk. If for example the common mode crosstalk is 20 dB higher than the differential mode crosstalk and a skew of 10 ps exist at both sides of the connector in a 25G link (about -8 dB in mode conversion at half baud rate, see Fig 1.) then will the differential crosstalk, caused by the skew, be -8 dB + 20 dB -8 dB = +4 dB. This crosstalk caused by the skew will be 4 dB higher than the pure differential crosstalk and then dominate the crosstalk picture. The skew effects can not be neglected if the common mode crosstalk is high compare to the differential crosstalk. In a crosstalk section is normally also a mode conversion taking place, a conversion from differential mode to common mode. For some skew settings on the aggressor channel will this mode conversion and common mode crosstalk be in phase and add up. For other skew settings they will cancel out each other and reduce the output common mode signal. The skew on the receiver channel will also be in phase or out of phase of the common mode crosstalk signal. This crosstalk, caused by the skew, is added to the pure differential coupled crosstalk. The phases of the crosstalk caused by the skew and the pure differential coupled crosstalk will strongly influence the total differential crosstalk. To find the worst crosstalk situation different combinations of the aggressor skew and the receiver skew must be investigated. One skew combination will give highest crosstalk in one frequency area and another combination might give highest crosstalk in another frequency area. The mode conversion from skew takes place at the edge of the signal transition. If there are two skew sections together with a common mode crosstalk coupling in between and the skew is short compare to the pulse width. Then will the differential crosstalk signal, out from this skew section, be a sinusoidal pulse shaped signal generated on each signal transition. The period time of the pulse will be close to the bit length. The spectra content of this pulse train will be high in frequency. The majority of the crosstalk noise power will be around 10 GHz in a 25G link. The level of common mode crosstalk around 10 GHz is then very important for the crosstalk coupling caused by skew.

Fig. 5. Example of differential pair, pin and via arrangement to minimize differential crosstalk

IV. Structures with high common mode crosstalk The common mode crosstalk takes place in different types of structures. Listed below are some structures that suffer from high common mode crosstalk. Microstrip routing; Tight routed differential microstrip traces will have

a rather high common mode crosstalk much higher than stripline. Microstrip routing needs then larger spacing to minimize common mode crosstalk. Microstrip has also different propagation velocity for differential mode and common mode signals. A length compensation is then needed to be placed close to where the length mismatch occurs otherwise will the differences in speed make the length compensation not to work.

20

Fig. 6. Crosstalk in a 10 mm length of shifted differential pairs with and without skew

Fig. 7 shows a rather common used via pattern for connectors. Here is the signal vias as red and ground vias as black. To the right is the differential mode NEXT and common mode NEXT plotted. The common mode NEXT is about 30 dB higher than differential NEXT in a large frequency range. The thickness of the backplane is 4 mm.

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

Fig. 7. Common used via pattern for connectors and NEXT Ground return path inside connectors; To maintain a good current return

path for common mode is difficult inside a connector. There should be a ground that encapsulates all the electromagnetic fields from the signal pins. There should be no leakage of fields between differential pins and to get this a 360° shield should be placed around each differential pair. But in the mating area is it difficult to maintain this field encapsulated structure. Often the ground structure starts to get a shape of a pin or the structures got holes and cut outs. Also at the side of the connector is it difficult to maintain the 360° shield. Through the openings in the shield will the fields leak and create crosstalk. Especially the common mode fields will leak through openings as all common mode fields will be terminated to the ground shield.

V. Sources of skew Skew can be created in different ways in a link. Listed below are some structures that can generate skew in a channel. Different trace length within the pair; Mismatch in length will create

skew. Stripline will generate approximately 7 ps skew per mm in length difference. Layout tools have support to avoid mismatch in length so this is normally in control. But it is important to compensate length differences prior entering vias etc. because differential mode and common mode have different velocity through a coupled via and a length compensation after a via will then not work. One need also be careful in length compensation for microstrip. Microstrip has different propagation velocity for differential mode and common mode signals. To eliminate introduced length mismatch the compensation should be placed close to the where the length mismatch is generated otherwise will the differences in speed make the length compensation not to work.

constant around 3. The glass weave consists of woven fills and warps. These fills and warps are as bundles if they are not spread out. A trace placed over a bundle will se higher dielectric constant than a trace placed between two bundles, see Fig. 8. The lower trace will see a higher dielectric constant than the upper trace. The differences in dielectric constant generate a skew due to the difference in propagation velocity for the traces. A dense weave as 2116, 7628 etc. gives smaller variations in the electrical environment. A more open weave gives larger variations. Reference [1] and [3] gives indications that a skew up to 9 ps/25 mm might be expected for dense weave. With longer traces parallel with the weave higher skew will be expected. The level of skew will vary from PCB to PCB and must be treated as a probability function. If for example the total lengths of traces that are parallel with the weave are 30 mm or longer then can we expect, to a certain probability, that the skew will exceed 10 ps and for traces longer than 60 mm the skew will exceed 20 ps. One way to minimize the weave effect is to route the traces with an angle to the weave, to avoid 0°, 45° and 90° angle to the weave. But this type of routing need larger area on the PCB and this area might not exist. Also in the breakout area of integrated circuits and connectors it might not be possible to place traces in a non 0° and 90° angle fashion. To rotate the PCB on the panel might reduce the utilization of the panel and increase the PCB cost.

VI. Conclusions Skew is a major source to mode conversion, a conversion from differential mode to common mode signal and vise versa. Often are component/ structures in a channel with poor common mode properties used. For example, a component with very high common mode crosstalk. If there is a new mode conversion after the common mode crosstalk then will this common mode crosstalk signal be converted into a differential signal. This differential crosstalk signal, passing as a common mode signal through the component, can be much higher than the pure differential crosstalk. The skew will vary from PCB to PCB and the crosstalk level will then vary from PCB to PCB. If the link passes a backplane or a cable the combinations of PCB’s will set the crosstalk level. One combination of PCB’s might fail due to high bit error rate caused by the skew combinations. By exchange one PCB the link will probably work again. This, from PCB to PCB, random crosstalk level is hard to investigate and difficult to find the fault if one board is pointed out as faulty. Common mode properties in connectors, via structures etc. together with assumptions of skew levels should be considering in the analyze of a link. To ignore the common mode effects might give high fault rate in volume production. The supports from simulation tools to handle skew in links are normally limited and require large man work to cover.

Weave effects; The dielectric material used in PCB consist of resin/epoxy

Ingvar Karlsson

and glass fiber weave. The electrical properties of resin and glass weave are different and give an inhomogeneous dielectric environment. Normal used glass has a dielectric constant of 6 and the resin has a dielectric

Fig. 8. Example of traces in relation to glass weave

Ericsson AB ingvar.q.karlsson@ericsson.com

REFERENCES [1] Dianyong Chen. SerDes Transceivers for High-speed Serial Communications. [2] Eben Kunz et al. Oracle Corp. Sources and Compensation of Skew in Single-Ended and Differential Interconnects. DesignCon 2014. [3] Peerouz Amleshi et al. Molex Inc. Intra-pair “Unaccounted” Skew Effects and Suppression. DesignCon 2014

www.electronic.nu – Electronic Environment online

21


Electronic Environment #4.2017

Produktnytt New Bandpass and Low Pass Filters FAIRVIEW MICROWAVE INC., a supplier of on-demand microwave and RF components, has introduced a new series of low pass and bandpass filters for use with multiple popular frequency bands. Fairview’s 13 new SMA coaxial filters consist of seven bandpass filters and six low pass filters. The bandpass filters were developed for use in various applications including GPS, ISM, RFID and Wi-Fi systems and operate in several bands, some as low as 824 MHz and some as high as 5.875 GHz. The new low pass filters allow for tailoring of the test setup for a specific application and support upper band edges of 100, 225, 400, 1000, 2000 and 3000 MHz. All of these new RF filters are available off-the-shelf and feature SMA female connectors. Källa: Fairview Microwave

GREY SHIELD – Intelligent Concrete technique for global shielding of facilities or compartimented premises. With the exponential growth of the radio environment and sources of electromagnetic radiation, the need to protect the premises against electromagnetic fields is expanding. Induced effects of such radiation can cause serious errors or equipment malfunctions resulting in data loss. Added the deliberate electromagnetic threats such as espionage (listening to radiation by using computer equipment before encryption), computer sabotage or hacking (destruction of material using electromagnetic pulse). GreyShield® is the solution to build premises that can limit the spread of electromagnetic waves from the inside out or from the outside towards the inside, thanks to the absorption of high-frequency waves by the fiber-reinforced concrete, combined with the optimum reflection of medium and low frequencies waves by a conducting mesh fixed on the wall. GreyShield® also offers a modular design that optimizes the electromagnetic attenuation / structural strength ratio, according to customer needs. Actually, the electromagnetic shielding performance A NEW REVOLUTIONARY

22

is calculable and essentially depends on the following elements: • Wire meshes 
• Nature of metallic fibers (or particles) • Ratio of fibers in concrete Keeping traditionnal building technique, GreyShield® provides an innovative solution that gives to buildings the electromagnetic attenuation performance that meets your expectations, without resorting to costly Faraday cages. • The products used in the composition of the process are all common construction items: concrete, fibers and wire mesh. • The process also keeps a traditional common type of hardware [ by screwing / bolting ] to put usual accessories in shielded premises, such as : doors, ventilation grids, feed-thru plates, electrical filters ... GreyShield® will save the additionnal building cost of a specific Faraday cage, since the local itself ensures the radio protection. In addition, the great durability of RF attenuation and the lack of maintenance of the wall result in an economical method compared to existing solutions. With equal properties, GreyShield®
can reduce the project cost by 50%

Source: EuroMC / Guillaume Souliac

Nytt högspänningsaggregat från Heinzinger HEINZINGER HAVE EXPANDED the production of their “best in class” EVO series of high voltage DC power supplies and are delivering new types from stock. Desktop/rack mount units are available up to 10kV and 3000W. Voltage classes 1.5kV, 5kV and 10kV are already in production. Compared to an equivalent 3kW regulated DC power supply, the EVO is approximately half the weight, half the size and delivers double the stability of line and load regulation – for a lower price. A 14-day, no obligation trial period is available for customers to test the units.

Standard features: Overvoltage and overcurrent protection Limit functions for voltage and current Interlock function Easily configurable diverse I/O contacts Optional functionality: Ramp function Arc detection Fast discharge circuit Electrical polarity reversal Communication interfaces Designed for “plug and play” operation Ethernet and RS232 using SCPI Easy-to-use, basic web browser Optional analogue interface

www.electronic.nu – Electronic Environment online

Källa: Proxitron


Electronic Environment #4.2017

TROUBLESHOOTING EMI (PART II, SUSCEPTIBILITY PROBLEMS)

SOME SIMPLE HINTS FOR

IDENTIFYING AND FIXING EMI TROUBLES Preamble. This second part of our EMI Troubleshooting guidelines is devoted to investigation and cure of EMI susceptibility problems. Since, according to our former article (Ref.1) conducted tests are faster and easier to perform, we will concentrate on these and avoid more complex and expensive radiated susceptibility test set-ups. The first half of this article will address the situation where the equipment at stake is still in the plant or lab, at the end of its development phase or in an early stage of production. The second half will cover the more difficult cases where the faultly equipment is already in service, installed at some customer site.

www.electronic.nu – Electronic Environment online

23


Electronic Environment #4.2017

1. TROUBLESHOOTING

EUT Preparation for the test

Susceptibility Problems on Prototype or Pre-Qualification item Only a limited set of tests can be carried using essentially conducted excitation set-ups, without (or before) resorting to an actual Radiated Susceptibility check in an EMC lab. Preferrably, as explained in Ref.1, susceptibility checks should be done after emission test have been carried-out, and eventually their non-compliance been investigated and solved. Notice that so-called "Susceptibility" tests are in fact made to demonstrate EUT Immunity. Therefore, we should always try to reach, within a reasonable span, the actual "Fail" threshold to get a measure of our Compatibility margin as compared to the Immunity "No-Fail" requirements.

1) Transients - E.S.D. (IEC 61000-4-2)

Severity

3. Testing for Immunity to Electrical Fast Transients

1 ns - Electrical Fast transients Power and Signal lines (IEC 61000-4-4)

50 ns

Uo

- High Energy Pulses (IEC 61000-4-5) (Lightning)

50 µs

Of all suceptibility tests, the EFT (or " Bursts") is the simplest to install and run, and yet one of the most meaningfull. Thanks to its wideband spectrum covering kHz to more than 60MHz at each single pulse, it will track down most of the EMC weaknesses of digital as well as analog circuits.

15 ms 0.25 - 4 kV

Logic functions can: – mistake the envelope of the bursts for a valid bits train of bits – have some edge-sensitive gate inputs triggered by individual short glitches – suffer clock stretching if the device fails to receive ACKs from the other device – loose signal integrity due to high noise on DC supply and Gnd to which communication I/Os are referenced, violating the protocol specification

0.25 - 4 kV (Z source : 2Ω, 10Ω or 40Ω)

1 µs

2) Continuous

E=1-10V/m modul. 1 kHz 80%

RF Fields (IEC 61000-4-3) - 30 to 1000 MHz+

With analog circuits, the envelope of the burst can be detected in a same manner as pulse modulated radio signals.

- Can be replaced by cable injection _ 80 MHz (or 230 MHz)

Fig. 1. Summary of Susceptibility/Immunity tests

Like for emissions, we try staying away from formal Radiated Susceptibility (R.S) tests, and use substitute conducted tests instead. These conduction (or injection) tests are deemed to recreate on the EUT what its cables (power and signal) and internal circuits would actually receive from a severe, conducted or radiated threat. So, by order of simplicity and efficiency we will limit our tests to: – Electrical Fast Transients (EFT Bursts) – ESD ( Direct and Indirect) – Bulk Current Injection (Continuous Wave )

2. Requirements for informal Suceptibility Test site and EUT set-up The site requirements for an informal EMC Immunity test are the same as for emissions (Ref. 1), except that the quiet RF ambient requirement is exactly the opposite: a quiet ambient is not necessary. Instead, since susceptibility tests will force strong HF signals or fast pulses, it is prudent to forbid, or temporary discontinue the use of sensitive electronic equipments ( computers, office equipment and instruments other than intentional EMI generators) in close proximity - say less than 5m from the test set-up. For the same mirror reasons as above, it is recommended to filter and if possible isolate the AC power branch circuit that feeds the EUT and set-up. This can be done by the same LISN and isolation transformer that were used for emission testing. During the susceptibility test, we will limit the Auxiliary Equipments (AE) to a minimum, using everywhere possible passive loads at the end of I/O cables. A good example is a Tx/Rx link that can be set in self-looping mode. As for emissions tests, the AEs must have an Immunity level equal (or greater) to the one we are testing for. If this is not feasible, an added, temporary filtering on their interfaces, or Coupling/Decoupling Network (CDNs) can be used to isolate the AEs from the EUT.

24

a) Constantly activates a real, or close-to-real application w/o operator intervention b) Indicates clearly a disability or loss of performance by, like : • displaying errors • printing a report • activating a visual, or audio alarm ( LED, buzzer etc ..) • reset or lock-up in a frozzenstate All this without the need of external instrumentation/ hook-up probes, unless they are fiber optic links. This is paramount to a meaningful test.

2 - 8 kV (contact) 15 kV (arc in air)

60 ns

Bear in mind that you will be "teasing" the product to see if and how it fails. To easy-up the test, the EUT must be set in an automatic mode such as it performs its normal functions continuously. This can be done using an auto-test mode, or a specific emulation software which :

Because it simulates the direct or indirect coupling of switching transients on the AC distribution wiring ( relays, repetitive arcing in switches, turn-off of heavy-duty motors, variable frequency converters etc ...) caused by nearby power devices, the test is applied both on the power input and signal cables, per IEC 61000-4-4.

3.1 Instrumentation and set-up EFT generator and EUT should be installed on the test ground plane (floor level or workbench with metal foil. Cables are laid at approximately 5cm above with insulating spacers (Fig.2). The generator should not be too close from the EUT, since 4kV pulses with 5ns riste times are hefty transients that radiates a strong E-field. Close exposure of the EUT could cause a direct box-to-box failure that would mislead the test issue. Same remark applies to the AE particiapting to the test. – For superimposing HF pulses on power cord, the generator has its own internal Coupling/ Decoupling network, such as the fast bursts are injected on the EUT only and do not sneak into the lab power mains. Normal injection is CM ( Line 1+ Line 2 together vs chassis), but it is possible to select any combination of L1, L2 and earth ( Green/ Yellow). – EFT injection on I/O cables is a contact-less coupling (no stripping of cable sinsulation), applied with a special capacitive clamp, 1m long that can be folded over the tested cable (Fig 2). Beware that this folding armature is the coupling "hot plate", reaching up to 4kV and must not be touched or approached during the test. Since its size and weight can be impractical for some non-standard set-ups, it can be replaced by a tight wrap of aluminium foil, 30 to 50cm wide, around the tested cable, that will provide the necessary 60-100pF of distributed capacitance to the tested wires. The HV injection cable from the generator should be ≤ 1m long.

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017 Warning: if a fix does not seem to bring a significant improvement, do not remove it. Add another one: EMI is often a multipath scenario.

EFT burst generator Power mains Filter

L1

High-V wire

4. Electro-Static Discharge (ESD) Test

2x100µH L2

Capacitive coupler

L1 EUT

Power cord

V

Burst No load, 50Ω 300 ms

1 0,9 0,5 0,1

Signal

15 ms

v

4.1 Instrumentation and test set-up

t Test voltage ± 10%

Severity level Power mains (kV) 1 2 3 4

One-pulse wavwform in 50 Ω

5 ns 50 ns Output impedance: Rep. rate: Max. energy:

Next to EFT, the ESD test is a also powerful teller of potential EUT weaknesses. It covers in a single flash an even wider frequency spectrum, up to 350MHz considering its 0,7-1ns risetime, but at difference with the EFT conducted bursts, it generates also a strong and fast rising H-field on the EUT box itself. You are directly zapping in a few ns a broad frequency spectrum that would take hours to explore during a real RF immunity test.

0.5 1.0 2.0 4.0

I/0 lines (kV) 0.25 0.50 1.00 2.00

• The most common instrument is an ESD generator conforming to IEC 61000-4-2, with 330Ω Internal resistance and 150pF capacitance (Fig.3). Other simulators can be used according to the familly of EUT being tested. • Horizontal and Vertical Coupling plates ( HCP, VCP) if the EUT must be tested for Indirect discharge (IESD). EUT preparation and set-up precautions are the same as for other immunity tests, with a strong emphasis on proper decoupling or safe distance of the associated AE, if any. The location of the ESD current ground return lead is critical: it should be attached to the test ground (floor) plane on the same EUT side as the face being tested.

t 50 Ω ± 20% (1 to 100 MHz) 2,5 kHz to 100 kHz 4 mJ/pulse (2 kV into 50 Ω)

Fig. 2. EFT/ Surge generator and test set-up, for both standard and on-site conditions. Immunity levels recommended by IEC 61000-4-4 are those for which the EUT should exhibit no error or malfunction.

Vacuum Relay (bounceless) 50-100MΩ

3.2 EFT Test routine For all injections, test at least 30s on each polarity. Do not switch abruptly from (+) to (-) pulse polarity, always step through an "Off" mode in-between. Consider this as a no-damage // no error criteria :the low amount of energy in each pulse is such that a damage level is seldom reached without a preliminary warning by a malfunction or error. DO NOT insist for reaching a true damage level ! Keep your prototype safe and investigate the reasons of the temporary fault – or lock-up status. a) Begin with power cable first. If nothing else specified, start with the lower level of IEC 61000-4-4, then increase progressively up to at least a No-Fail level #3 (2kV) which is genrally satisfactory. However, for a development test, it is advisable to try reaching one level higher to know your margin... b) Increase the level progressively, preferably by octave steps, addressing combinations of L1, L2, L1+L2 and so on, with (+),(-) polarity. When (if) a FAIL level is reached, note the settings for all the last RUN levels. If the generator has progressive voltage setting,reduce the amplitude until you find the actual RUN/FAIL edge, such as you know your margin. c) Inject onto each signal cable, keeping the capacitive coupling sleeve 1m away from the EUT. If external cables are shielded, the test is simply applied over the shield insulation jacket. If an AE was needed for the test monitoring, make sure that this AE has its input protected by proper filtering or snap-on ferrites toroids, located near the AE side.

330MΩ

EUT

150pF

HV±

Ground strap

Probe for air discharge: Similar to 1984 standard

Probe for contact discharge

Ø8 25º–40º

Ipeak 1 (100%) 90% Ipeak2 at 30 ns I at 60 ns 10% 30ns

Ƭr = 0.7 to 1 ns

60ns

t

Level (Contact Discharge)

HV (kV)

Ipeak2 (± 10%)

Ipeak2 at 30ns (± 30%)

I at 60ns (± 30%)

1 2 3 4

2 4 6 8

7.5A 15A 22.5A 30A

4A 8A 12A 16A

2A 4A 6A 8A

3.3 EFT Test diagnosis and Fixes If the test fails, concentrate on the failing port ( Power or Signal ) and check for: – Incorrect mounting, or insufficient CM attenuation of the powerline filter – Missing or poor cable shield connections – Ungrounded metallic connectors – Lack of, or improperly mounted CM filtering capacitors (long leads) – I/O wiring running too far inside the EUT before they are filtered Improve immunity by correcting the above, eventually adding filtered connector/adapters, or split-ferrites (2 or 3 turns) to the faultly I/O cable. Re-do the test, starting from the latest "NO FAIL" level as a reference, to grade the improvements.

Fig. 3. ESD simulator characteristics. Severity 1 is an absolute minimum. For equipment in ESD-prone areas, aim for severity 3 or 4. Highest severity for air-discharge (no contact) is 15kV. Charging/discharging circuit is generally packaged in a compact, hand-held "gun". Right: ESD gun offering several options for discharge heads (Courtesy EMC Partner ).

www.electronic.nu – Electronic Environment online

25


Electronic Environment #4.2017

4.2 ESD Test routine

4.3 ESD Test diagnosis and Fixes

At difference with the EFT continuous train of high voltage bursts, ESD replicates an isolated, rarely-occuring event. Therefore, exceptions accounted, there is no point in applying an "absolutely-NO error" criteria. If the EUT has efficient error detection and recovery mode, this can be considered as an acceptable response, provided it does not result in a lock-up status, requiring a manual reset or creating a safety issue.

If the test fails, try understanding what are the sensitive circuitry that has been exposed to the close coupling of the discharge. Be on the look for long slots or seams leakages on the EUT enclosure, that act as re-radiating antennas to the nearby wiring or PCB traces inside.

a) Establish the Direct or Indirect (IESD) procedure you will be using (ref. IEC 61000-4-2). Briefly, if the EUT is metallic on all its faces, only direct ESD will be performed. Otherwise direct discharge will be attempted on all touchable or arc-reachable metal parts, the rest of the EUT being tested by the IESD method on the HCP and VCP. Insist on cable entry areas, keyboard and display edges, touch sensitive panels. Mark-up the pre-determined discharge points directly on the EUT faces or on 3-D sketch. b) Start with a low level (e.g 2kV) in a fast repetitive mode, like 5 or 20 pulses/sec for a coarse survey of all the discharge zones. c) Increase the level progressively by 2kV steps until you reach the desired criterion plus a 1-2kV margin. d) If failures are noted, abandon the fast repetitive mode and return on the failing area with a single shot, or ≤ 1 pulse/sec. mode, such as allowing for the EUT self-recovery process, if any. Run a minimum of 50 discharges per point. ESD is a super-short duration, random event: applying only a few discharges (the 10 discharges recommended in IEC norm are definitely not enough) would turn into a risky hit-or-miss process. e) Record the Run/Fail levels, documenting the type of error/malfunction: Recoverable ? Non-recoverable ? Loss of data ? Ind. discharge on VCP

Exempel for a direct discharge EUT

Typical position for indirect discharge on HCP

VCP (0,5x0,5)

Insulating support

HCP Conductive ground plane

2x470k Wooden (damping) table h=0,8 m

Fig. 4a. ESD generator and test set-up, table-top equipment. The Horizontal and Vertical Coupling plates are used to simulate a discharge on a nearby structure, especially when testing an unshielded equipment. (Courtesy AEMC, France)

When trying fixes such as : • Shielding (or shielding improvement) of I/O cables • Shielded connectors, ferrites, decoupling capacitors • Better bonding of panels, doors etc … to the main chassis (for metal cabinets or racks) • Reduction of slots and seams leakage by gasketting or adding more screws • Increasing the air gap crossing distance for zones where air discharges have occured Always grade your progress via new Run/Fail mappings. Like for EFT, do not remove a fix that gave disappointing results. Accumulate them until success, then and only then, remove fixes sequentially to find the ones that could be useless.

4.4 Indirect ESD on a PCB prototype or pre-production item. If your analysis of the ESD test has indicated which functional circuit is disturbed, it could be worth focusing on the specific PCB (or set of) that is hosting this function. For this, the EUT housing should be removed, keeping only the metallic base plate, or if it is a plastic case, the topless EUT will be installed on a large aluminium or steel plate. Having spotted the circuits that are susceptible to ESD, identify some connector pins or printed traces that can "witness" the functional status of the essential circuits (for inst. WatchDog, Reset, Power ON, IRQ etc...). On these traces or pins, solder a LED whose state will indicate a Good/Bad status for the corresponding function. Disconnect all I/O cables that are not absolutely necessary. The PCB can eventually made fully a stand-alone by attaching a battery pack to the board, equipped with clip-on teminals for easy turn-off. Test Routine for IESD on a PCB Attach the ESD gun ground post to the test ground plane by a short grounding strap (fig.5). The discharge is applied to the EUT bottom plate (or substitute coupling plate), following a contour of ≈ 5-10 cm from the board edge. Start with low level like 0,5kV and discharge the tip of the ESD gun all around the marked-up designated contour, trying to reach progressively 4-6kV. Although it gives no quantitative assessment, this test is a simple way to pin-point weak spots and find out the layout flaws or specific components responsive of the poorest immunity, thus inviting improvements. Then, try temporary fixes and grade your improvements. DO NOT try direct contact discharges on PCB traces or connector pins. ESD Gun Short Gnd strap

Contour for contact discharge on Ref.Plate Good/BAD status LEDs

Aluminium or steel sheet Insulating stand-off

Fig. 5. ESD immunity test on PCB of a prototype / pre-production item.

5. Bulk Injection of HF current on external cables (BCI test)

Fig. 4b. ESD generator and test set-up for a floor-standing equipment, or a on-site evaluation

26

Next to EFT and ESD, this test is a powerful indicator of EUT susceptibility to strong RF ambients, from intentional radio transmittrers. It consist in injecting via a clamp-on current transformer the same HF signal as the cables would see if they were exposed to a real field. The difference being that you do not need to generate this field. This test is required by Mil Std 461/CS114, with values of injected HF current ran-

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

ging from 15 to 300mA, and to some extent, is also part of IEC immunity test 61000-4-6. Unfortunately, running this test makes your EUT cables radiate a significant RF field, which could make you liable for an illegal interference to public radio and TV as far as km away. We do not recommend trying it elsewhere than in a shielded room, or at least an underground place.

the injection probe. But when monitoring the injected current, do not try re-adjusting the current for maintaining the calibration value. Let the bundle current establish by itself, depending on the actual impedance of the cable-to-ground loop. What counts is that the induced open-voltage keeps the value that was set during calibration.

5.1 Quick, simplified calibration of the injection set-up The key element for making this test more than a qualitative investigation is a proper calibration of the injection tool (Fig.6). This calibration will allow a quantitative assessment of the radiated field coupling that you mimic by this substitution method. A simple rule is as follows: When cable length exceeds ≈ ¼ wavelenght, the current Ii induced by a given Field in V/m no longer depends on frequency and settle to a maximum value around 1mA / (V/m). Only the cable height above the local ground plane has a small influence on the amplitude of Ii. More detailed values of cable Common Mode current is given on Table 1. Table 1. Induced CM current on a cable (or cable bundle) for a constant E field: 1V/m, depending on cable height. Conditions: F > 30MHz, cable length ≥ 2,50m Cable height: 0,05m : 1.5mA / (V/m) (typ of Mil Std, Aerospace or vehicle testing)

Cable height: 0,75m : 6.5mA / (V/m) (typ of civilian, table top equipment)

Examples:

10 0

Cover plate (Alum)

mm

For a vehicle or aircraft equipment that can be exposed to a 100V/m field, the calibration current in the test jig must be set to: 1,5 mA x 100V/m = 150mA. For a civilian, table-top equipment that can be exposed to a 10V/m field, calibration current must be set to: 6,5 mA x 10V/m = 65mA

”N” or BNC connector

Coaxial Load 50Ω, 5W 40 mm Thick aluminium bracket

to spctr. Analyzer 50 Ω input

Fig. 7. Investigation /prequalification BCI test set-up, BCI current calibration table with E-field equivalent . BCI test is a substitute to an actual illumination of the entire system cables by very strong fields.

6. EMC HARDENING FOR EQUIPMENT installed at customer site EMI problems occuring in the field are a difficult challenge. This is a case where there is very little possibility, if at all, for modifying the equipment. All solutions are relying on cable layout, shielding, additional I/O and power filtering, power conditioning and eventually room or site treatment. Even if, as of today, most electrical/electronic equipment put on market has to meet rather severe EMC requirements, suceptibility and emissions incompatibility problems still happen. Reasons for this are multiple: – a recent, large system could include older equipments that do not comply with current EMC norms – poor cabling and grounding practices by unaware contractors that degrade an otherwisecorrect immunity – some sensitive equipments that are impossible to harden, by their very nature (magnetic sensors, E-Beam microscopes) or generate strong disturbances (elevators, arc welders, RF medical imaging, some indusrial process) The following basic guidelines will save you from frustrating experiences at customer's site where people telling you that they have already tried everything, rely on your magic wand for making miracles.

6.1 Before going to the site 100 mm

Aluminium stud, 12,5 mm dia. with insulating sleeve

Fig. 6. Home-made BCI calibration jig. With the injection clamp is in place, the injected current is known by the measure of the voltage on the 50Ω output . I = V(50Ω) / 50

In many cases, we have found that rushing to a problem site because the user is pressing you may induce two mistakes: – you do not collect enough data for preparing a sound investigation scheme – you either bring too many or too few instruments or measuring devices, leaving behind the one precious accessory that cannot be found on site Instead, there are things you must check in advance ("Forewarned is forearmed"):

5.1 Bulk cable injection test routine The EUT is installed like for the Conducted Emissions (Ref 1) or EFT test. The tested cable is laid 5cm above the ref. metal ground plane. The other end can be terminated on a passive load. The AE representing the peripheral unit is isolated, HF-wise, from the test by a Coupling Decoupling Network, or at least a set of CM ferrites, close to the AE ( Fig.6). The injection probe is fed by a signal generator, teamed with a power amplifier capable of feeding a sufficent power to the probe, taking into account the probe transfer ratio, some cable loss and a 4 times margin (6dB, in power). Exemple: Necessary power For a calibrated BCI current of 10mA: 0,1 W (a Sig. Gen with 2V output is enough) 30mA : 1W ( power amplifier needed) 100mA: 10W ( power amplifier needed)

Starting with low levels, increase the generator level up the its pre-calibration setting. The input signal must be amplitude-modulated by a low AM , with at least 50% modulation. For sake of checking that a loop current actually exist, a monitoring current probe is added, near

a) Interview the users • Is the problem continuous or intermittent ? in the latter case, is it predictable, like being re-created on request ? This may dictate the equipment you will bring • Does the failure correlate with a specific time of day ? Or with certain loads being on/off the power distribution ? When people use portable transmitters ? b) Any instrumentation available on site ? • Oscilloscopes: which Bandwidth ? Battery-operated ? • Any recorders for intermittent problems ? Thus you will bring whatever is necessary to complement the instrumentation available on site. In any case, don't forget bringing an EMC clamp-on current probe. c) Sometimes, based on the above, a fast, rough estimate can be done on the likelihood of the problem, if the data you have collected suggest what is the source, its frequency range, what and where is the victim device and what are the possible coupling path. d) Plan some advance strategy for diagnosis and fix. Don't count that the first attempt will work, anticipate alternate options.

www.electronic.nu – Electronic Environment online

27


Electronic Environment #4.2017

6.2 Upon Arriving at the site Perform a first Inspection of the EUT and its physical Installation:

A

a) On the faultly equipment: Does it have power line filters, with CM and DM elements? Are they bonded to a chassis or a grounded metal plate, and correctly mounted (no input and output wires entangled together)?

6.3 Continuous or quasi-continuous EMI problems

What type of malfunction? Can it be quantified? – S/N – Rate of errors or alarms Switch off as many devices att the same time in the installation

yes

Is malfunction continuous or quasicontinuous no

b) General Power grounding/Earthing scheme: Ask the customer's staff or facility maintenance people about it. Don't take anything for granted: bonding points that seem to make good contacts don't; Grounding straps that people swear have been installed are missing or loose; Asked about the neutral earthing scheme, six different people will give you six different versions; Once checked, you'll find that none of them is true. c) Power and signal interconnecting cables layout. Examine all of them. Are there some power and signal bundles running thightly close to each other, or near to other power cables carrying large currents? Are they shielded? If so, where and how are the shields grounded? Are they in metal raceways, with continuous metal-to-metal bonding all along?

{

Identify victim equipment of subassembly

yes

Check for intermittent sources: • air elevator • elevator • electronical equipment • mobile radio • arc welder • etc.

B

Problem disappears?

yes

By this, we mean that the problem is always present or repeats within a reasonable observation period, such as it can be probed and quantified: S/N degradation, bad Bit/Error rate, false alarms…etc. If it has been checked that the equipment is in otherwise good condition, a continuously occuring problem is a blessing of sorts, since it eases-up the search for the source and the subsequent fixes. A procedure is recommended on Fig. 7.

no

yes Culpit identified, focus on conducted manifestations

Any likelihood of ESD?

yes/ maybe

If possible, install transient recorde on power line

For source(s) that cannot be switched off, assess the likelihood of possible cond. or radiated coupling path

Problem not related to local source

no

Forced crash: ESD testing and hardening

Any power-line transient correlated with problem?

Measure LHF on external cables compare with criteria of Table 2

yes Harden victim against power-line disturbances using forced crash

no

6.4 Measuring CM currents as "witnesses" of the EMI paths

E

Have you switched off all electrical sources?

no Can be a rarely occurring transient

D

no

Reoperate all sources sequentially until you catch the culprit

Any correlation?

C

Forced crasch: EFT on signal and power lin

1

Once (if) the source has been identified, the likely coupling path(s) can be identified by a quick measurement of the Common Mode HF currents at Fig. 7. EMI troubleshooting routine for on-site investigations. If malfunction the following locations: is quasi-continous, a measurement of HF current on cables may be needed, – power input wiring (CM) leading to a further investigation (see Fig.8) – signal and various interconnect cables (CM) – earth wires 1 Make sure that the culprit source is functionning when you make your measurement. An oscilloscope with sufficient bandwidth (≥100MHz) is Record IHF on: recommended, using eventually its memory function if the culprit source • power conductor (DM, CM) • signal leads, incl. shielded is operating with various sequences. Make sure to use a 50Ω input for pairs and coax There is no detectable conducted • ground wires and straps the scope. Using the current probe transfer impedance Zt, convert your symptom. Organize list, check again Problems can be directly: against Table 2 voltage readings into current, using: • radiated into victim’s box • received by victim’s antenna, if it is a radio receiver I (Amp) = V / Zt(Ω) One or more Check for high values of no cables with IHF > E- or H-field ambient. Be careful that the probe response (Zt) is not always flat with frequency, default values? Eventually shield box or room. so you need at least a rough idea of the frequency of the probe voltage no signal. Is power line yes (Fig. 7.) (DM or CM) the largest?

Table 2. Order of magnitude of "Sure Immunity" and "Sure Suceptiblity" for CM current readings, from ≈10 kHz to 100MHz HF current on power mains cables HF current on signal cables, digital HF current on signal cables, low-level analog HF current on earthig/ ground wires

No problem High chance of problem < 10mA @ worst frequ. ≥ 300mA 3mA

≥ 100mA (300mA if shielded)

0.3mA

≥ 100mA (300mA if shielded)

1A (but fault protection installed)

no B

Largest I is on power and signal cables?

Install an afficient filter (CM+DM) on (preferebly) the source or victim’s power lead. Consider a filtered UPS if DM, low-freq. problem, or shielded isolation transformer if CM, low-freq. problem.

no Largest I on some signal line, and eventually on ground conductor

Does this cable run close to some culprit cable

no

no

Upon the results of this CM current survey on all cables, a further investigation can lead to identify the cable(s) that is the likely coupling path for the problem. Fig.8 give guidance for treating such paths.

6.5 Intermittent Problems These represent a respectable % of field calls, with a long search to find a correlation between a rarely-occuring problem and some external cause. If the source is found within the customer premises, it may be worthwile seeing if the noise can be suppressed at its source, by adding filters, or box / cable shielding. Sometimes after a patient search, the external cause is

Try to harden signal link(s) first (easier). • decoupling and filtering • shielding (If there are already shielded cables, check shield connections, both ends.

End

Treat crosstalk coupling: d

End h

28

yes

Large ground loop involving power and signal cables.

• Separate culprit from victim cable by at least 10 x h and 10 x d • Shield culprit or victim, or press into a metal raceway

If not enough, complete with power-line suppression.

Note: Reducing at the source side is recommended. However, if the source has not been identified, or if its current rating would lead to a prohibitively large filter, suppression at the victim’s side is the only choice.

Fig. 8. EMI troubleshooting routine continued from Fig.7, when malfunction is quasi-continous and measurement of HF current on cables has been made.

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

found but you have no control on it (an elevator nearby, an arc-welder in a machine shop one block away etc..). Ultimately, no correlation has been found. These are cases where we will use the forced-crash approach, by recreating artificially an event that we cannot afford waiting for.

(Fig 2). If these levels are not met, use the fix hints in section 3.3. Some of these fixes maybe applicable on-site, without too much disruption for the user. Other fixes could make-up for design weaknesses that you cannot improve on an installed equipment. Those you will apply on the installation itself:

6.6 Failures that cannot be correlated: "Forced Crash" Approach If answer to Box "B" routine in Fig.7 is NO, no correlation has been found between the failure and some intermittent event on the site. Such events can be artificial or natural, occuring at irregular times in this site like severe electrical fault triggering overcurrent protections or ground fault detectors (GFD), or eventually storms. In such case, some searching in the history of local lighning strokes, or power disruption in some part of the building can provide clues if they correlate with the moment of the failures. Although more difficult to track, a second random cause, may be the normal ON/OFF switching of low power electromechanical switches, relays, thermostats … etc, in close vicinity ( less than 10m) from the victim. Finally a third threat, ESD, has generally a seasonal relationship, like increasing during cold and dry weather, aggravated by high personnel activity and type of floor covering. But it may be also machine-originated ESD, with some production tools, robots etc … causing ElectroStatic charging/ discharging phenomena with peak currents exceeding 50A, that may go un-noticed. In all these cases above the "Forced Crash" is an ultimate strategy where you decide that you cannot wait for some hard-to-catch problem to showup, so you deliberately inject onto the equipment a transient pulse (or train of pulses) that is "shaking", EMI-wise, the victim equipment. The best simulators for this kind of artificial threat are the EFT and ESD. Starting with low levels, the applied pulses will be increased until the equipment starts exhibiting malfunctions. If the "FAIL" threshold is significantly lower than the immunity level that should be expected for this equipment and environment, you will harden one or the other until this installed equipment meets or exceeds the immunity for its category. Accordingly, over some probation period of a few days or weeks, the user should report a reduction, or disappearance of the problem. The driving assumption is: If it withstands the standard immunity level on site, this equipment is vaccinated against any kind of short, fast-rising transient, even if the true cause is never found.

6.7 Common Precautions to EFT and ESD on-site "forced crash" method The principle of the set-up and routine are basically the same as for development tests, with some noticeable differences in the actual application, considering that you miss the commodities of a design/development lab. Instead, you are on a customer's site, with probably other equipments that are still running, people doing their regular work etc... This implies some precautions, like working off-hours or temporary isolating some section of the plant or building. a) There will probably be no ground plane, so you will use the next, closest metal framework (building girders for instance) as a reference for connecting a temporary aluminium foil. The EFT generator will be grounded to this foil. The EUT will NOT be grounded to the foil, but will keep its normal (presumably safety earth wire) connection to the power panel earth bar. b) You are testing an equipment that is actually in use. As the test is progressing, watch for the symptoms that have been noticed by the users. Make sure that your crash evaluation does not lead to material damage or eventually safety hazard. Ask for putting in standby mode any peripheral that could create such a risk.

Fig. 9. On-site injection of EFT

6.9 Forced Crash using ESD simulator This method is for the cases where there is a suspicion that the problem could be ESD (answer YES in Fig. 7 box D. It precisely reveals weak spots on the equipment box and I/O ports area, that an EFT test may have missed. The test procedure is similar to that of lab test, Sect.4. For an installed equipment, the NO-Fail levels of Fig.3 are recommended. Warning

This supposed to be a No-Damage test. Errors are normally tolerated if they are self-recovered, without serious prejudice to the user. Hard errors, especially if they resemble the ones that the EUT user was complaining about are not acceptable. Do not discharge directly on EUT parts that are directly wired to sensitive circuits inside (like connector pins of Digital Bus interfaces, video or RF inputs etc ..), unless the normal factory test of the EUT did include this requirement. Due to the high voltages (up to 15kV) on the tip of the ESD gun, this method can be dangerous for an equipment whose susceptibility is unknown (never tested by the manufacturer) or even for personnel. Make sure your temporay test area is bound with visible warning tape.

7. Power Line Monitoring There is a domain that an on-site EFT test will not reveal: long-duration power mains disturbances, typically longer than a few tens µs. These are difficult to simulate on-site, because it would require injecting significant disturbances that could affect part or all the AC distribution in this customer's facility. So, if occasional power line disturbances are suspected, it is recommended to install a power-line disturbance monitor. This "spy" instrument will survey constantly the short overvoltages and undervoltages, indicating their amplitude, duration, and precise time of occurance (day, hour, minute). If the sensors are correctly installed, they will show if the disturbance was DM ( line-to-line) or CM (Line to Gnd). Choose (they are often available for rental) an equipment with battery back-up, and select a sensing threshold equal to what could exceed the normal (proven) immunity of the EUT to power line. If after some observation period, the EUT had suffered the failures the user was reporting, you will find if they correlate with some power mains disturbances, and eventually install surge protection devices or a power conditioning (UPS).

Michel Mardiguian EMC Consultant, France

c) For EFT, if the EUT power cord does not fit into the generator outlet, use the aluminium foil wrapping on the power cord, like for the signal cable (See Sect. 3.1).

6.8 Forced Crash using EFT simulator This method is, by far, the preferred test to start with, since it requires less time and preparation, being performed on power cables and signal cables only, that are typical weak spots of a system. Test ALL cables, starting from a low level. For those AE which must functionnaly operate with the EUT, use ferrite decoupling, as described in Sect 3. The EUT must resist on site, to levels that are at least equal to the IEC 61000-4-4 Table

m.mardiguian@orange.fr REFERENCES 1. EMI troubleshooting, Part I, September 2017 issue of EE magazine 2. M.Mardiguian, EMI troubleshooting Techniques (Mc Graw Hill) 3. M.Mardiguian, Electrostatic Discharge ( Wiley) 4. H. Ott , Workbench EMC measurements, H.Ott 2012 www.hottconsultants.com 5. K.Wyatt, Troubleshooting Radiated Immunity for Medical Products, Interference Technology Oct 9, 2017

www.electronic.nu – Electronic Environment online

29


Electronic Environment #4.2017

Forskning Grafen möjliggör höghastighetselektronik på böjbara material EN BÖJBAR DETEKTOR för terahertzfrekvenser (1000 gigahertz) har utvecklats av forskare på Chalmers med hjälp av grafentransistorer på plast. Det är den första i sitt slag, och kan utöka användningsområdet av terahertzteknik till tillämpningar som kräver böjbar elektronik, exempelvis trådlösa sensornätverk och kroppsnära teknik. Resultaten är publicerade i den vetenskapliga tidskriften Applied Physics Letters.

Terahertzstrålning har en lång rad användningsområden och kan förekomma i allt från radioastronomi och säkerhet till medicin. Begreppet syftar på de elektromagnetiska vågor vars frekvenser sträcker sig från 100 gigahertz till 10 terahertz. Efterfrågan på högre bandbredd inom trådlös kommunikation och avbildning för säkerhetstillämpningar har lett till intensifierad forskning på system och komponenter avsedda för terahertzfrekvenser. En utmaning har länge varit att skapa lätta och billiga applikationer. Framstegen inom polymertekniken har dock främjat utvecklingen av flexibel elektronik och möjliggjort tillverkning av högfrekventa enheter på böjbara underlag. Nu har chalmersforskarna Xinxin Yang, An-

drei Vorobiev, Andrey Generalov, Michael A. Andersson och Jan Stake tagit fram den första mekaniskt flexibla och grafenbaserade terahertzdetektorn i sitt slag. De öppnar därmed för flexibel terahertzelektronik. Detektorn har unika egenskaper. I rumstemperatur upptäcker den signaler i frekvensområdet från 330 till 500 gigahertz. Den är genomskinlig och böjbar, och öppnar för en rad tillämpningsområden. Tekniken kan bland annat användas för avbildning i terahertzområdet (THz-kamera), men även för att identifiera olika ämnen (sensor). Den kan också vara till potentiell nytta inom sjukvården, där terahertzvågor kan användas för att upptäcka cancer. Andra områden där detektorn skulle kunna användas är sensorer för fordon och trådlös kommunikation. De unika elektroniska egenskaperna hos grafen kombinerat med dess flexibla natur gör det till ett lovande material att integrera i plast och tyg, något som kommer att vara viktiga byggstenar i en framtida sammankopplad värld. Grafenelektronik möjliggör nya applikationer för bland annat vardagsföremål, det som brukar kallas sakernas internet (Internet of Things). Detektorn visar på de konkreta möjligheterna

DELTA – Ditt val för EMC, elsäkerhet, miljötålighet och utbildning

Vi kan nu som ett av de första testlabben i Europa erbjuda transienttester enligt IEC 61000-4-18 ” fast damped oscillatory wave” och även inom kort immunitet för magnetfält med styrkor upp till 1000A/m. Läs mer om oss på www.madebydelta.se !

30

www.electronic.nu – Electronic Environment online

med grafen, som leder ström otroligt bra. Det är en egenskap som gör grafen till en attraktiv byggsten i snabb elektronik. Chalmersforskarnas arbete är därför ett viktigt framsteg när det gäller grafen inom terahertz-området, och ett genombrott mot högpresterande och billig flexibel terahertzteknik. Detektorn väckte uppmärksamhet på EU-toppmötet Tallinn Digital Summit nyligen, där flera viktiga tekniska innovationer som möjliggjorts av grafen och besläktade material visades upp. På toppmötet samlades EU:s stats- och regeringschefer för att diskutera digital innovation och Europas digitala framtid. Flaggskeppets fokus var att visa vilken roll grafen kan spela. Forskningen utgör även en del av Xinxin Yangs licentiatavhandling, som presenteras på Chalmers den 22 november 2017. Forskningen om terahertzdetektorn har finansierats av EU:s forskningsflaggskepp om grafen, Graphene Flagship, Stiftelsen för strategisk forskning (SSF), och Knut och Alice Wallenbergs Stiftelse (KAW). Källa: Chalmers


LECs – en allt mer lovande supertunn ljuskomponent

Med hjälp av det tvĂĽdimensionella materialet grafen har den fĂśrsta flexibla terahertzdetektorn utvecklats av forskare pĂĽ Chalmers. ILLUSTRATION: BOID STUDIO, GĂ–TEBORG

FORSKARE VID UMEĂ… och LinkĂśpings universitet har tagit fram starkt lysande elektrokemiska celler (LECs) som är betydligt effektivare än tidigare. Som sĂĽdan är den tunna, flexibla och lätta ljuskällan lovande fĂśr kommande och fĂśrbättrade tillämpningar inom hemdiagnostik, belysning, enkla displayer och hälsovĂĽrd. En ljusemitterande elektrokemisk cell (LEC) är en tunn, flexibel och lätt plastliknande ljuskälla. Den kan drivas av ett batteri, avger ljus med väsentligen vilken färg som helst, och tillverkas till en lĂĽg kostnad med en metod som liknar hur tidningar tillverkas i en tryckpress. Hittills har en bestĂĽende och problematisk nackdel varit att forskarna inte kunnat frambringa LEC-enheter med bĂĽde starkt ljus och hĂśg effektivitet. I tidskriften Nature Communications visar ett forskarteam frĂĽn UmeĂĽ universitet, LinkĂśpings universitet och fĂśretaget LunaLEC AB i Sverige en väg mot att lĂśsa detta problem. Med hjälp av en systematisk kombination av experiment och simuleringar har de etablerat en allmän uppsättning designprinciper, som inkluderar balanserade elektronfällor, optimerad dopning och elektrokemiskt stabila material. Forskarnas ansats har banat vägen fĂśr LEC-komponenter som lyser med en hĂśg ljusstyrka av 2 000 cd/m2 vid en elektron-till-foton effektivitet av 27,5 procent. – Siffran kan jämfĂśras med en standard TV med en maximal ljusstyrka mellan 300 och 500 cd/m2, medan 2000 cd/ m2 är en typisk ljusstyrka pĂĽ en OLED-belysningspanel. Vad gäller effektivitet ligger vĂĽr LEC-komponent nära den hos vanliga fluorescerande lysrĂśr, säger Ludvig Edman som leder projektet och är professor pĂĽ Institutionen fĂśr fysik vid UmeĂĽ universitet. Källa: UmeĂĽ Universitet

LeverantĂśr av det mesta fĂśr de flesta inom EMC

www.stigab.se E-post: info@stigab.se Tel: +46 8 97 09 90

RONSHIELD AB Kallforsvägen' 27 % &) * $ '+$ SE-124 32 Bandhagen % Tel. +46 8 722 71 20 - Mob. +46 70 674 93 94 & #% #'!( *('+"# % + E-mail: info@ronshield.se

,,, *('+"# % +

www.ronshield.se

www.electronic.nu – Electronic Environment online

31


Electronic Environment #4.2017

Noterat

Framtidens infrastruktur i fokus i Göteborg Provinn AB stod som arrangör för ett Microwave Road-arrangemang den 9 november i lokalerna på Kvarnbergsgatan i Göteborg. Evenemanget hade som tema ”Connected Vehicles” och lockade mer än 40 deltagare. Kvällseventet började med fyra inbjudna presentationer med föredragshållare från Qamcom, AB Volvo, Volvo Cars och Zenuity och avslutades med ett samkväm med mat och dryck, ett uppskattat inslag i höstmörkret. Föredragen behandlade allt från tekniska aspekter av radarövervakning av järnvägsövergångar, via fordonskommunikation för trafiksäkerhet till hur tekniken skall implementeras vad gäller både hårdvara och hur infrastrukturen skall se ut i det framtida samhället.

Facts about Microwave Road Microwave Road is an organization of about 30 Microwave and Antenna companies with activities in western Sweden, established in 2003. In the beginning Microwave Road was more of a regional idea where highway 40 (Riksväg 40) played an important symbolic value as it connects some of the biggest microwave players in the region. This is also the background for the name. Microwave Road is a non-profitable organization which is financed by membership fees and run by an elected board, and includes giants as Huawei and Ericsson down to several SMEs. The business areas grasp telecom, space, defense, medicine, food, measurement and test. It includes academia, research institutes, industry and public organizations.

Ny bok om EMC VARFÖR ÄR DET så svårt att få ut en förståelse för EMC? Den frågan ställde sig Mikael Klasson, Jan-Olof Brink och Urban Lundgren för fem år sedan. Nyligen släpptes deras bok Introduktion till EMC på Studentlitteratur och Adlibris. – Vi som håller på med EMC har svårt att få förståelse för att man måste konstruera för EMC redan från början. Företag kommer på att man måste uppnå EMC alldeles för sent i konstruktions- och utvecklingsfasen, det är oftast när man ska få produkten, systemet CE-godkänt man upptäcker att man inte klarar EMC-kraven. Det säger Mikael Klasson som är en av författarna till boken och som för flera år sedan såg ett behov av en introduktion i ämnet. – För att uppnå EMC är det inte bara att man ska ha rätt kretskortskonstruktion med kretsval, kretsplacering och ledningar rätt dragna, utan också att alla interface måste vara rätt. Alltså alla don och kablar är rätt och att luckor har plats för eventuell skärmning. Vilket innebär att även mekanister måste förstå EMC. Vidare att kombinera miljö- och EMC-krav kan vara ett gissel, säger Mikael. I boken Introduktion till EMC beskriver författarna ämnet på ett enkelt, övergripande och lättfattligt sätt. Innehållet är upplagt så att boken både kan användas som ett uppslagsverk och läsas i utbildningssyfte. Introduktion till EMC är tänkt som en första introduktion till EMC-området och som läsare behöver du inte ha några speciella förkunskaper, endast en grundläggande förståelse för ellära. Boken finns att beställa på Studentlitteratur och Adlibris.

janlinders.com

Din produkt – vårt fokus.

Vi vet vad som krävs för att din produkt ska uppfylla regulatoriska krav.

www.janlinders.com | +46 31 744 38 80 | info@janlinders.com

32

www.electronic.nu – Electronic Environment online


Electronic Environment #4.2017

Elektronikkonsult startar ny EMC-tjänst

Elsäkerhetsverket fick pris

EN STOR DEL av alla produkter klarar inte EMC kraven när provningen görs första gången på ett oberoende testlabb. Resultatet blir att man får göra om provningen med ökade kostnader och förseningar i produktlanseringen som följd. – För många konstruktörer har vi märkt att de inte vet hur de ska tackla EMC-problemen som uppstår i samband med provningen. Testhusen ska ju vara oberoende och då blir det svårt att ge för mycket rådgivning. Där kan vi bistå med vår expertkompetens inom EMC, säger Vidar Wernöe, VD på Elektronikkonsult. Elektronikkonsult har sedan 1978 hjälpt företag med elektronikkonstruktion och EMC-problem. Den nya tjänsten, EMC-problem.nu (www. emc-problem.nu), fokuserar på att ge akut hjälp för att produkten ska klara EMC- och elsäkerhetskraven, men också rådgivning för att göra rätt från början. I verksamheten finns ett stort elektroniklabb med bra mätplats för EMC, och för många kan det vara väl investerad tid att i ett tidigt skede ta hjälp av en EMC-expert. Genom att ta hänsyn till konstruktionens EMC-egenskaper från start får man en bättre produkt som kan lanseras i rätt tid. – I många uppdrag ser vi att man inte har gjort en ordentlig kravspecifikation och därmed missat krav som behövs för CE-märkningen. Ett vanligt problem är också brister i mönsterkortslayouten och filtrering. En enkel konstruktionsgranskning och verifiering av EMC-prestanda skulle i många fall öka chanserna avsevärt för att klara certifieringen, avslutar Vidar Wernöe. Källa: Elektronikkonsult

SVERIGES MODERNASTE MYNDIGHET ligger i Kristinehamn och heter Elsäkerhetsverket. Under Kvalitetsmässan i Göteborg fick myndigheten ta emot priset som Sveriges modernaste myndighet 2017. – Jag är väldigt glad och stolt över utmärkelsen, säger Elsäkerhetsverkets generaldirektör, Elisabet Falemo. Det är ett fantastiskt fint kvitto till alla medarbetare som varit med och utvecklat verksamheten, samtidigt som vi sjösatt en modernare elsäkerhetslagstiftning. Ett förtroendefullt samarbete med andra myndigheter, branschorganisationer och fackliga organisationer har betytt mycket.

Juryns säger i sin motivering att: ”På den här myndigheten har man vågat ompröva gamla arbetssätt och idag utförs uppdraget på ett nytt sätt och med ett tydligt fokus på att uppnå största möjliga samhällsnytta. Under omställningsarbetet har myndigheten visat på sin förmåga att agera snabbfotat, och på värdet av öppenhet mot och involvering av sina intressenter. På myndigheten ser man hellre möjligheter än hinder och gör inte saker svårare än de behöver vara. Här står också utvecklingen av statstjänstemannarollen högt på agendan och medarbetarna ser sig som ambassadörer för myndigheten och dess uppdrag.” – Det är jättekul att vi som en ganska liten myndighet kan vinna priset, säger Elisabet Falemo. Vi har byggt vidare på kompetensen som finns bland personalen, släppt in externa referensgrupper tidigt i förändringsprojekt och även riktat våra insatser mot nya målgrupper för att bli ännu mer effektiva. Våra medarbetare har medvetet klivit ur sin bekvämlighetszon, allt för att möta de förväntningar och behov som finns, säger Elisabet Falemo. Källa: Elsäkerhetsverket

EMC LIFE SIMPLIFIED SLIPP OMPROVNING SLIPP DYRA FILTERLÖSNINGAR Vill du förenkla ditt utvecklingsarbete? Tillsammans går vi igenom din produkt och du får råd och stöd så att den klarar EMC-kraven.

SLIPP ONÖDIGA KORTRUNDOR I TID FÖR LANSERING

Med våra råd sparar du både tid och pengar - du hamnar rätt direkt. Vi har en bred kompetens inom EMC - allt fordonselektronik till installationer och sateliter i rymden - vi vet vad som krävs för du skall klara kraven. Kontakta Tony Soukka, tel 0734-180 981 eller tony@emcservices.se för att diskutera ditt projekt.

EMC SERVICES

KNOWLEDGE IN REALITY

www.electronic.nu – Electronic Environment online

www.emcservices.se

33


Electronic Environment #4.2017

Branschnytt Yokogawa adds CXPI automotive serial bus analysis option to DLM oscilloscope series CXPI – CLOCK EXTENSION Peripheral Interface – is a new automotive serial bus interface that is designed to provide an optimised solution in applications previously served by the established CAN and LIN bus systems, which until now have been the main interfaces used for in-vehicle communications. In particular, as more sensors and human-machine interfaces are used in vehicles and controls become ever more sophisticated, the new bus helps to minimise system power consumption through electronic control as well as reducing vehicle weight by using lighter components, especially in wiring harnesses. With LIN, it is difficult to achieve sufficient reliability and communication response when multiplexing in HMI applications. CAN is better for reliability and communication response, but the cost is higher than LIN. The CXPI protocol, on the other hand, is a lowspeed low-cost communication protocol that is capable of reducing wire counts to simple devices like switches and sensors. CXPI was standardised in 2015 under SAE J3076 as a communications bus for diverse automotive applications. The bus uses pulse-width modulation to transmit data over a single wire at 20 kbit/s. The characters used are based on UART. CXPI has the CSMA/CR system (event initiate system) built into the polling system of LIN, which

provides higher response time and scalability, and significantly reduces HMI and development costs. It has reduced the number of the parts needed for the clock side of the design because a data and a clock signal can transmit at the same time via PWM. When equipped with the CXPI option, the DLM Series oscilloscopes will decode and display CXPI frames in real time, produce a list display of the decode results, and allow highlighting of points on the list for display in a zoom window. After the acquisition, dedicated parts of the display can be searched for a number of specified conditions. An auto setup feature can be used to analyse the

input signals, set the time and voltage axes automatically along with various trigger settings such as threshold levels, bit rates and trigger type, and then display the decoded result. Yokogawa’s DLM2000 and DLM4000 mixed-signal oscilloscopes combine a fast update rate with exceptionally long memory plus a combination of flexible analogue and digital outputs that make them ideally suited to a range of measurement and analysis tasks in the electronics, automotive and mechatronics sectors. Källa: Yokogawa

Ferner Elektronik har utsett till svensk representant för APM Technologies APM TILLVERKAR programmerbara DC spänningsaggregat och deras PPS-serie består av 12 olika modeller med utspänningar från 0-20V upp till 0-800V. Totalt består serien av närmare 80 olika DC spänningsaggregat med strömmar från 4A upp till 200A och uteffekter 600W till 4000W. APM tillverkar också avancerade AC

aggregat. SP-serien har utspänning upp till 0-300V med strömmar från 5A upp till 46A och uteffekter 500W till 5000W. Givetvis kan utfrekvensen varieras mellan 15Hz till 1200Hz. Totalt består serien av 14 aggregat uppdelade på Advanced och Professional lite beroende på användarens behov. Källa: Ferner Elektronik AB

Sänk dina projektkostnader – använd standarder! Underlätta och förbättra ditt arbete inom det elektrotekniska området – www.elstandard.se 34

www.electronic.nu – Electronic Environment online

Fastställer all svensk standard inom elområdet Svensk medlem i IEC och CENELEC


Författare

Electronic Environment #4.2017

Författare – Electronic Environment Electronic Environment överbygger kunskap inom specifika elektronikområden – mellan myndigheter, högskola och universitet samt näringslivets aktörer. Det kan vi göra tack vare ett stort intresse och engagemang från många duktiga skribenter och deras organisationer. Sedan tidningens första utgåva 1994 har ett stort antal skribenter bidragit med sin kunskap, till mångas glädje och nytta. Här presenterar vi våra skribenter de senaste åren, och i vilka nummer du kan läsa deras bidrag. Ett stort tack till er alla som bidragit genom åren till tidningens utveckling! Dan Wallander / ansvarig utgivare

TEKNIKREDAKTÖRER Michel Mardiguian Teknikredaktör EMC Consultant 2/2015, 3/2015, 4/2015, 1/2016, 2/2016, 3/2016, 4/2016, 1/2017, 2/2017, 3/2017, 4/2017

Miklos Steiner Teknikredaktör Electronic Environment 4/2014, 1/2015, 2/2015, 3/2015, 4/2015, 1/2016, 2/2016, 3/2016, 4/2016, 1/2017, 2/2017, 3/2017, 4/2017

Peter Stenumgaard Teknikredaktör FOI – Swedish Defence Reasearch Agency 4/2014, 1/2015, 2/2015, 3/2015, 4/2015, 1/2016, 2/2016, 3/2016, 4/2016, 1/2017, 2/2017, 3/2017, 4/2017

Björn Gabrielsson FOI – Swedish Defence Reasearch Agency

Jan Welinder RISE Elektronik

Mats Bäckström Saab Aeronautics, Saab AB

3/2014

3/2016, 4/2017

1/2014

Christer Karlsson Ordf. Swedish Chapter IEEE EMC RISE 4/2014, 1/2015, 2/2015, 3/2015, 4/2015, 1/2016, 2/2016, 3/2016, 4/2016, 1/2017, 2/2017, 3/2017, 4/2017

Jenny Skansen ABB Power Systems

3/2014, 4/2014, 1/2015

Sten E Nyholm FOI – Swedish Defence Reasearch Agency

Mattias Elfsberg FOI – Swedish Defence Reasearch Agency

3/2016

1/2015

K G Lövstrand FMV T&E

Mikael Alexandersson FOI – Swedish Defence Reasearch Agency

3/2016

Karin Davidsson RISE Elektronik

Dag Stranneby Campus Alfred Nobel, Örebro universitet

3/2014, 4/2014, 1/2015

Karin Fors FOI – Swedish Defence Reasearch Agency

Erling Pettersson STRI AB

3/2015

1/2016

Kia Wiklundh FOI – Swedish Defence Reasearch Agency

FÖRFATTARE

2/2017

Joeri Koepp Rohde&Schwarz

3/2015

3/2014, 4/2014, 1/2015

Mats Lindgren RISE Elektronik

1/2015, 1/2016

Carl Samuelsson Saab Aeronautics, Saab AB

2/2014

1/2015

1/2015, 2/2015, 3/2015

3/2016

Torbjörn Persson Provinn AB

Patrik Eliardsson FOI – Swedish Defence Reasearch Agency

4/2016, 3/2017

1/2015, 2/2015, 3/2015

Göran Jansson Saab Bofors Testcenter

Kristian Karlsson RISE Elektronik

Per Ängskog Högskolan Gävle/KTH

Anders Thulin ATC AB

3/2014

1/2016

3/2016

1/2014

Lars Falk Stigab AB

Peter Ankarson RISE Elektronik

Andreas Westlund Volvo Car Corporation

Hartmut Berndt B.E.STAT European ESD competence centre, Germany

2/2015

4/2014

3/2017

2/2014

Peter Larsson KTH

Ann-Kristin Larsson Swedavia

Henrik Olsson Elsäkerhetsverket

Lars-Erik Juhlin ABB Power Systems 1/2016

1/2014

3/2014, 4/2015

Anneli Waara Uppsala universitet

Henrik Toss RISE Safety and Transport

Leif Adelöw FOI – Swedish Defence Reasearch Agency

Peter Stenumgaard FOI – Swedish Defence Reasearch Agency

1/2015

3/2014, 4/2014, 3/2015, 4/2015, 1/2016, 4/2016, 1/2017, 3/2017

4/2016, 3/2017

Tomas Hurtig FOI – Swedish Defence Reasearch Agency

Niklas Karpe Scania CV AB

3/2014, 4/2014, 3/2015, 3/2016, 4/2016, 1/2017, 3/2017

Björn Bergqvist Volvo Cars

1/2015

Mose Akyuz FOI – Swedish Defence Reasearch Agency

2/2017

3/2016

Susanne Otto Reliability DELTA Test & Consultancy

Tomas Bodeklint RISE Elektronik

Gunnar Englund GKE Elektronik AB

Bengt Vallhagen Saab Aeronautics, Saab AB

1/2015, 2/2015, 3/2015

1/2014

Anders Larsson FOI – Swedish Defence Reasearch Agency

3/2014

Simon Loe Spirent Communications

2/2016

Ulf Carlberg RISE Elektronik 4/2014

Åsa Larsbo Intertek Semko 1/2014

3/2017

Lennart Hasselgren EMC Services

Ingvar Karlsson Ericsson AB

2/2015

1/2017, 4/2017

Marcus Eklund El/Tele Västfastigheter

Jan Carlsson Provinn AB

2/2016

4/2014, 1/2016, 3/2017

Ulf Nilsson Electronic Environment 2/2015

1/2016

Pär Weilow Swedavia 1/2014

Sara Linder FOI – Swedish Defence Reasearch Agency 3/2015

www.electronic.nu – Electronic Environment online

35


Företagsregister Acal AB Solna Strandväg 21 171 54 Solna Tel: 08-546 565 00 Fax: 08-546 565 65 info@acal.se www.acal.se Adopticum Gymnasievägen 34 Leveransadress: Anbudsgatan 5 931 57 Skellefteå Tel: 0910-288 260 info@adopticum.se www.adopticum.se

Alpharay Teknik AB Runnabyvägen 11 705 92 Örebro Tel: 019-26 26 20 mail@alpharay.se www.alpharay.se Produkter och Tjänster: Antistatutrustningar för industrin: elektronikproduktion, precisionsvägning, plasttillverkning, lackering. Lämpliga för Ex-miljö. Egen import, försälj-ning och service.

Aleba AB Västberga allé 1 126 30 Hägersten Tel: 08-19 03 20 Fax: 08-19 35 42 www.aleba.se Alelion Batteries Flöjelbergsgatan 14c 431 37 Mölndal Tel: 031-86 62 00 info@alelion.com www.alelion.com/sv

AMB Industri AB 361 93 Broakulla Tel: 0471-485 18 Fax: 0471-485 99 Amska Amerikanska Teleprodukter AB Box 88 155 21 Nykvarn Tel: 08-554 909 50 Kontaktperson: Kees van Doorn www.amska.se Amtele AB Jägerhorns väg 10 141 75 Kungens Kurva Tel 08-556 466 04 Stora Åvägen 21 436 34 Askim Tel: 08-556 466 10 amtele@amtele.se www.amtele.se Anritsu AB Borgarfjordsgatan 13 A 164 26 Kista Tel: 08-534 707 00 Fax: 08-534 707 30 www.eu.anritsu.com

36

Electronic Environment #4.2017 ANSYS Sweden Färögatan 33 164 51 Kista Tel: 08-588 370 60 Vestagatan 2 B 416 64 Göteborg Tel: 031-771 87 80 info-se@ansys.com www.ansys.com

BRADY AB Vallgatan 5 170 69 Solna Tel: 08-590 057 30 Fax: 08-590 818 68 cssweden@bradyeurope.com www.brady.se www.bradyeurope.com

Armeka AB Box 32053 126 11 Stockholm Tel: 08-645 10 75 Fax: 08-19 72 34 www.armeka.se

Bromanco Björkgren AB Rallarvägen 37 184 40 Åkersberga Tel: 08-540 853 00 Fax: 08-540 870 06 info@bromancob.se www.bromancob.se

Axiom EduTech Gjuterivägen 6 311 32 Falkenberg Tel: 0346-71 30 30 Fax: 0346-71 33 33 www.axiom-edutech.com

Båstad Industri AB Box 1094 269 21 Båstad Tel: 0431-732 00 Fax: 0431-730 95 www.bastadindustri.se

Berako AB Regulatorv 21 14149 Huddinge Tel: 08-774 27 00 Fax: 08-779 85 00 www.berako.se

CA Mätsystem Sjöflygsvägen 35 183 62 Täby Tel: 08-505 268 00 Fax: 08-505 268 10 www.camatsystem.se Cadputer AB Kanalvägen 12 194 61 Upplands Väsby Tel: 08-590 752 30 Fax: 08-590 752 40 www.cadputer.se

BK Services Westmansgatan 47 A 582 16 Linköping Tel: 013–21 26 50 Fax: 013–99 13 025 johan@bk-services.se www.bk-services.se Kontaktperson: Johan Bergstrand Produkter och Tjänster: BK Services erbjuder EMCprovning, elsäkerhetsgranskningar (LVD), radioprovning enligt bl.a. ETSI standarder, maskinsäkerhetsgranskningar, hjälp med CE märkning och klimattester. Vi erbjuder högkvalitativa och priseffektiva tjänster, problemlösningshjälp samt vänligt och proffesionellt bemötande.

Bodycote Ytbehandling AB Box 58 334 21 Anderstorp Tel: 0371-161 50 Fax: 0371-151 30 www.bodycote.se Bofors Test Center AB Box 418 691 27 Karlskoga Tel: 0586-84000 www.testcenter.se Bomberg EMC Products Aps Gydevang 2 F DK 3450 Alleröd Danmark Tel: 0045-48 14 01 55 Bonab Elektronik AB Box 8727 402 75 Göteborg Tel: 031-724 24 24 Fax: 031-724 24 31 www.bonab.se

Caltech AB Fågelviksvägen 7 145 53 Norsborg Tel: 08-534 703 40 Fax: 08-531 721 00 www.caltech.se CCC Solutions AB/Carpatec Rallarvägen 23 184 40 Åkersberga Tel: 08-540 888 45 hl@cccsolutions.eu http://www.cccsolutions.eu

CE-BIT Elektronik AB Box 7055 187 11 Täby Tel: 08-735 75 50 Fax: 08-735 61 65 info@cebit.se www.cebit.se CLC SYSTEMS AB Nygård Torstuna 740 83 Fjärdhundra Tel: 0171-41 10 30 Fax: 0171-41 10 90 info@clcsystems.se www.clcsystems.se Combinova Marketing AB Box 200 50 161 02 Bromma Tel: 08-627 93 10 Fax: 08-29 59 85 sales@combinova.se www.combinova.se Combitech AB Gelbgjutaregatan 2 581 88 Linköping Tel: 013-18 00 00 Fax: 013-18 51 11 emc@combitech.se www.combitech.se Compomill AB Box 4 194 21 Upplands Väsby Tel: 08-594 111 50 Fax: 08-590 211 60 www.compomill.se

DELTA Development Technology AB Finnslätten, Elektronikgatan 47 721 36 Västerås Tel: 021-31 44 80 Fax. 021-31 44 81 info@delta-dt.se www.delta-dt.se DeltaElectric AB Kraftvägen 32 Box 63 196 22 Kungsängen Tel: 08-581 610 10 www.deltanordicgroup.se/ deltaeltech

Detectus AB Hantverkargatan 38 B 782 34 Malung Tel: 0280-411 22 Fax: 0280-411 69 jan.eriksson@detectus.se www.detectus.se

EMC Services Box 30 431 21 Mölndal Besöksadress: Bergfotsgatan 4 Tel: 031-337 59 00 www.emcservices.se Kontaktperson: Tony Soukka tony@emcservices.se Produkter och Tjänster: EMC Services erbjuder provning, rådgivning, problemlösning och utbildning inom EMC-området. I vårt EMC-laboratorium i Mölndal utför vi EMC-mätningar på alla möjliga produkter och kan även ta in större objekt som t.ex. bilar. Vi har utrustning för att utföra mätningar på plats hos kund och kan även erbjuda miljö- och vibrationsprovning. EMC Services ingår i försvarskoncernen Saab.

Kontaktperson: Jan Eriksson Produkter och Tjänster: Instrument, provning. Detectus AB utvecklar, producerar och säljer EMC-testsystem på världsmarknaden. Företaget erbjuder också hyra och leasing av mätsystemet. Detectus har möjlighet att utföra konsultmätningar (emission) på konsultbasis i egna lokaler.

DeltaEltech AB Box 4024 891 04 Örnsköldsvik Tel: 0660-29 98 50 www.deltanordicgroup.se/ deltaeltech/

Emicon AB Head office: Briggatan 21 234 42 Lomma Branch office: Luntmakargatan 95 113 51 Stockholm Tel: 040-41 02 25 or 073-530 71 02 sven@emicon.se www.emicon.se Contact: Sven Garmland Need Help With Your Electromagnetic Environment?

EG Electronics AB Grimstagatan 160 162 58 Vällingby Tel: 08-759 35 70 Fax: 08-739 35 90 www.egelectronics.com

Products and Services: We have more than 30 years of experience from research and development in the field of electromagnetic interference.

Elastocon AB Göteborgsvägen 99 504 60 Borås Tel: 033-22 56 30 Fax: 033-13 88 71 www.elastocon.se

We can help you with: • Interference control • Advice • Specifications • Testing for EMC, EMP, HPEM and lightning • Field tests, current injection and coupling measurements • Electromagnetic simulations • Analysis and measurements on small and large-scale systems, anything from circuit boards to complex facilities. • Measurement and test system integration • Software for EM simulations, measurements and instrument control • Shielding and Ground ing

ELDON AB Transformatorgatan 1 721 37 Västerås Tel: 010-555 95 50 eldonindustrial.se@eldon.com www.eldon.com/sv-SE Electronix NG AB Enhagsvägen 7 187 40 Täby Tel: 010-205 16 50 Elis Elektro AS Jerikoveien 16 N-1067 Oslo Tel: +47 22 90 56 70 Fax: + 47 22 90 56 71 www.eliselektro.no

www.electronic.nu – Electronic Environment online

Visit www.emicon.se for further information.


Företagsregister

Electronic Environment #4.2017

EMP-Tronic AB Box 130 60 250 13 Helsingborg Tel: 042-23 50 60 Fax: 042-23 51 82 www.emp-tronic.se Kontakt person: Lars Günther Emp-tronic AB är specialiserat på Elmiljö- och EMCteknik.

Produkter och Tjänster: Vi har levererat skärmade anläggningar i över 25 år till bl.a. försvaret och myndigheter som skydd för EMP, RÖS, HPM med kontorsmiljö. Vi levererar även utrustning och skärmrum för EMC-mätning, elektronikkalibrering eller antennmätning, även med modväxelteknik. I vårt fullutrustade EMC-lab kan vi erbjuda verifierad provning för CE-märkning.

ELKUL Kärrskiftesvägen 10 291 94 Kristianstad Tel: 044-22 70 38 Fax: 044-22 73 38 www.elkul.se Elrond Komponent AB Box 1220 141 25 Huddinge Tel: 08-449 80 80 Fax: 08-449 80 89 www.elrond.se EMC Väst AB Bror Nilssons Gata 4 417 55 Göteborg Tel: 031-51 58 50 Fax: 031-51 58 50 info@emcvaest.se www.emcväst.se Emka Scandinavia Box 3095 550 03 Jönköping Tel: 036-18 65 70 ERDE-Elektronik AB Spikgatan 8 235 32 Vellinge Tel: 040-42 46 10 Fax: 040-42 62 18 info@erde.se web: www.erde.se ESD-Center AB Ringugnsgatan 8 216 16 Malmö Tel: 040-36 32 40 Fax: 040-15 16 83 www.esd-center.se Eurodis Electronics 194 93 Stockholm Tel: 08-505 549 00 Exapoint Svenska AB Box 195 24 104 32 Stockholm Tel: 08-501 64 680 www.exapoint.se

Helukabel AB Spjutvägen 1 175 61 Järfälla Tel: 08-557 742 80 Fax: 08-621 00 59 www.helukabel.se

Flexitron AB Veddestavägen 17 175 62 Järfälla Tel: 08-732 85 60 sales@flexitron.se www.flexitron.se Produkter och Tjänster: Vi erbjuder ett brett och djupt sortiment av produkter för EMC samt termiska material från tillverkare som är marknadsledande inom sina respektive områden. Exempel på produkter är skärmningslister, skärmburkar, ledande plast, färg, fett och lim, skärmburkar, genomföringsfilter, mikrovågsabsorbenter, etc. Vi har stor möjlighet att kundanpassa produkterna, aningen direkt från tillverkaren eller i vår egen verkstad.

ExCal AB Bröksmyravägen 43 826 40 Söderhamn Tel: 0270-28 87 60 Fax: 0270-28 87 70 info@excal.se www.excal.se Farnell Skeppsgatan 19 211 19 Malmö Tel: 08-730 50 00 www.farnell.se Ferner Elektronik AB Box 600 175 26 Järfälla Tel: 08-760 83 60 www.ferner.se FMV 115 88 Stockholm Tel: 08-782 40 00 Fax: 08-667 57 99 www.fmv.se Frendus AB Strandgatan 2 582 26 Linköping Tel: 013-12 50 20 info@frendus.com www.frendus.com Kontaktperson: Stefan Stenmark Garam Elektronik AB Box 5093 141 05 Huddinge Tel: 08-710 03 40 Fax: 08-710 42 27 Glenair Nordic AB Box 726 169 27 Solna Tel: 08-505 500 00 Fax: 08- 505 500 00 www.glenair.com Gore & Associates Scand AB Box 268 431 23 Mölndal Tel: 031-706 78 00 www.gore.com HCM Elektronik Sockenvägen 428 122 63 Enskede Tel: 08-659 99 15 Fax: 08-556 103 78 www.hcm.se

High Voltage AB Änggärdsgatan 12 721 30 Västerås Tel: 021-12 04 05 Fax: 021-12 04 09 www.highvoltage.se HP Etch AB 175 26 Järfälla Tel: 08-588 823 00 www.hpetch.se

Industrikomponenter AB Gårdsvägen 4 169 70 Solna Tel: 08-514 844 00 Fax: 08-514 844 01 www.inkom.se Infineon Technologies Sweden AB Isafjordsgatan 16 164 81 Kista Tel: 08-757 50 00 www.infineon.com Ing. Firman Göran Gustafsson Asphagsvägen 9 732 48 Arboga Tel: 0589-141 15 Fax: 0589-141 85 www.igg.se Ingenjörsfirman Gunnar Petterson AB Ekebyborna 254 591 95 Motala Tel: 08-93 02 80 Fax: 0141-711 51 hans.petterson@igpab.se www.igpab.se Instrumentcenter Folkkungavägen 4 Box 233 611 25 Nyköping Tel: 0155-26 70 31 Fax: 0155-26 78 30 info@instrumentcenter.se www.instrumentcenter.se

Jan Linders EMC-provning Bror Nilssons gata 4 417 55 Göteborg Tel: 031-744 38 80 Fax: 031-744 38 81 info@janlinders.com www.janlinders.com

Jolex AB Västerviksvägen 4 139 36 Värmdö Tel: 08-570 229 85 Fax: 08 570 229 81 mail@jolex.se www.jolex.se Kontaktperson: Mikael Klasson Produkter och Tjänster: EMC, termiska material och kylare Jolex AB har mångårig erfarenhet inom EMC och termiskt. Skärmningslister/kåpor, mikrovågsabsorbenter, icke ledande packningar, skärmande fönster/glas/rum/ dörrar, genomföringskondensatorer, kraftfilter, data-, telekom-, utrustnings- och luftfilter, ferriter, jordflätor, termiska material och kylare etc. Vi kundanpassar produkter och volymer.

Intertechna AB Kvarnvägen 15 663 40 Hammarö Tel: 054-52 10 00 Fax: 054-52 22 97 www.intertechna.se Intertek Torshamnsgatan 43 Box 1103 164 22 Kista Tel: 08-750 00 00 Fax: 08-750 60 30 Info-sweden@intertek.com www.intertek.se INNVENTIA AB Torshamnsgatan 24 B 164 40 Kista Tel: 08-67 67 000 Fax: 08-751 38 89 www.innventia.com Jontronic AB Centralgatan 44 795 30 Rättvik Tel: 0248-133 34 info@jontronic.se www.jontronic.se

Kontaktperson: Jan Linders Produkter och tjänster: EMC-provning, elektronik och EMC, utbildning, EMIanalys, allmän behörighet. Jan Linders Ingenjörsfirma har mångårig erfarenhet inom EMC-området och har allmän behörighet upp till 1 000 V. Bland vårt utbud märks ce-märkning, prototypprovning samt mätning och provning hos kund. Vi utför EMC-styling dvs förbättrar produkters EMC-egenskaper, ger råd och hjälp om standarder m m. Med vår nya EMC-tjänst tar vi totalansvar för er EMC-certifiering.

www.electronic.nu – Electronic Environment online

KAMIC Components Körkarlsvägen 4 653 46 Karlstad Tel: 054-57 01 20 info@kamic.se www.kamicemc.se Produkter och Tjänster: Med närmare 30 års erfarenhet och ett brett program av elmiljöprodukter erbjuder KAMIC Components allt från komponenter till färdiga system. Lösningarna för skalskydd omfattar lådor, skåp och rum för EMI-, EMPoch RÖS-skydd. Systemlösningar som uppfyller MILSTD 285 och är godkända enligt skalskyddsklasserna SS1 och SS2. Komponenter, ledande packningar och lister. KAMIC Components är en del av KAMIC Installation AB. Kontaktperson: Jörgen Persson. KEMET Electronics AB Thörnbladsväg 6, 386 90 Färjestaden Tel: 0485-56 39 00 TobiasHarlen@kemet.com www.kemet.com/dectron Keysight Technologies Sweden AB Färögatan 33 164 51 Kista Tel: 0200-88 22 55 kundcenter@keysight.com www.keysight.com

Kitron AB 691 80 Karlskoga Tel: 0586-75 04 00 Fax: 0586-75 05 90 www.kitron.com Kvalitest Sweden AB Flottiljgatan 61 721 31 Västerås Tel:076-525 50 00 sales@kvalitetstest.com www.kvalitetstest.com LAI Sense Electronics Rördromsvägen 12 590 31 Borensberg Tel: 0703-45 55 89 Fax: 0141-406 42 www.laisense.com LeanNova Engineering AB Flygfältsvägen 7 461 38 Trollhättan Tel: 072-370 07 58 info@leannova.se www.leannova.se

LINDH Teknik Granhammar 144 744 97 Järlåsa Tel: 018-444 33 41 Mobil: 070-664 99 93 kenneth@lindhteknik.se www.lindhteknik.se Lintron AB Box 1255 581 12 Linköping Tel: 013-24 29 90 Fax: 013-10 32 20 www.lintron.se LTG Keifor AB (KAMIC) Box 8064 163 08 Spånga Tel: 08-564 708 60 Fax: 08-760 60 01 kamic.karlstad@kamic.se www.kamic.se

37


Företagsregister Lundinova AB Dalbyvägen 1 224 60 Lund Tel: 046-37 97 40 Fax: 046-15 14 40 www.lundinova.se Magnab Eurostat AB Pontongatan 11 611 62 Nyköping Tel: 0155-20 26 80 www.magnab.se Megacon AB Box 63 196 22 Kungsängen Tel: 08-581 610 10 Fax: 08-581 653 00 www.megacon.se

LaboTest AB Datavägen 57 B 436 32 Askim Tel: 031-748 33 20 Fax: 031-748 33 21 info@labotest.se www.labotest.se Produkter och Tjänster: LaboTest AB marknadsför och underhåller utrustningar i Sverige till lab och produktionsavdelningar inom miljötålighet och test. Vårt huvudkontor finns i Askim och vårt filialkontor i Sollentuna. Våra huvudleverantörer är Vötsch och Heraeus. Båda har en världsomspännande organisation och är marknadsledande inom sina respektive produktområde. Vår verksamhet fokuseras främst kring följande produktområden: Värmeskåp, Torkugnar, Vakuumtorkskåp, Temperatur-, Klimattestkammare, Chocktest- kammare, Sol/Vädertestkammare, Vibrationstestkammare, Klimatiserade rum, Saltspraytestkammare, HALT/ HASS-kammare.

MTT Design and Verification Propellervägen 6 B 183 62 Täby Tel: 08-446 77 30 sales@mttab.se www.mttab.se Produkter och Tjänster: Sveriges mest omfattande utbud av instrument, tillbehör, mjukvara och skärmade lösningar för alla typer av EMC-test och analys från mark-nadsledande tillverkare som bl. a. PMM, Teseq, CST, EMSCAN, SIEPEL, och Milmega. MTT samlar över 60 års erfarenhet inom teknisk försäljning och support av testsystem, mjukvara och komponenter för elektronik, RF EMC och mikrovågsteknik samt elektromagnetisk och termisk simulering.

38

Electronic Environment #4.2017 Mentor Graphics Färögatan 33 164 51 Kista Tel: 08-632 95 00 www.mentor.com

OBO Bettermann AB Florettgatan 20 254 67 Helsingborg Tel: 042-38 82 00 Fax: 042-38 82 01 www.obobettermann.se

Metric Teknik Box 1494 171 29 Solna Tel: 08-629 03 00 Fax: 08-594 772 01

OEM Electronics AB Box 1025 573 29 Tranås Tel: 075-242 45 00 www.oemelectronics.se

Mikroponent AB Postgatan 5 331 30 Värnamo Tel: 0370-69 39 70 Fax: 0370-69 39 80 www.mikroponent.se

ONE Nordic AB Box 50529 202 50 Malmö Besöksadress: Arenagatan 35 215 32 Malmö Tel: 0771-33 00 33 Fax: 0771-33 00 34 info@one-nordic.se

Miltronic AB Box 1022 611 29 Nyköping Tel: 0155-777 00 MJS Electronics AB Box 11008 800 11 Gävle Tel: 026-18 12 00 Fax: 026-18 06 04 www.mjs-electronics.se MPI Teknik AB Box 96 360 50 Lessebo Tel: 0478-481 00 Fax: 0478-481 10 www.mpi.se

Prevas AB Hammarby Fabriksväg 21 A, 6 trp 120 30 Stockholm Tel: 08-644 14 00 maria.mansson@prevas.se www.prevas.se Kontaktperson: Maria Månsson Produkter: Utveckling

NanoCal AB Lundbygatan 3 621 41 Visby Tel: 0498-21 20 05 www.nanocal.se

Produkter och Tjänster: Spetskompetens inom elektronikutveckling: Analog och digital elektronik, EMCteknik (rådgivning och eget pre-compliance EMC-lab), inbyggda system, samt programmering. Regulativa krav som EMC-, MD- RoHSoch WEEE- EUP-direktiven. “Lean Design” med fokus på kvalitet, effektivitet, tillförlitlighet, producerbarhet och säljbarhet.

Nefab Packaging AB 822 81 Alfta Tel: 0771-59 00 00 Fax: 0271-590 10 www.nefab.se Nelco Contact AB Box 7104 192 07 Sollentuna Tel: 08-754 70 40 Nemko Sweden Enhagsslingan 23 187 40 Täby Tel: 08-47 300 30 www.nemko.no

Provinn AB Kvarnbergsgatan 2 411 05 Göteborg Tel: 031 – 10 89 00 info@provinn.se www.provinn.se Products and Services: Provinn offer EMC expertise covering all aspects from specification through consultant services, education, numerical analyses all the way to final verification. We are several dedicated EMC experts with documented expertise and experience. Provinn is proud representative for Oxford Technical Solutions (OxTS) navigational equipment, Moshon Data ADAS test equipment and Spirent GPS/GNSS instruments for the Scandinavian market.

Ornatus AB Stockholmsvägen 26 194 54 Upplands Väsby Tel: 08-444 39 70 Fax: 08-444 39 79 www.ornatus.se Para Tech Coating Scandinavia AB Box 567 175 26 Järfälla Besök: Elektronikhöjden 6 Tel: 08-588 823 50 info@paratech.nu www.paratech.nu Phoenix Contact AB Linvägen 2 141 44 Huddinge Tel: 08-608 64 00 order@phoenixcontact.se www.phoenixcontact.se

Nolato Silikonteknik AB Bergmansvägen 4 694 91 Hallsberg Tel: 0582-889 00 Nortelco AS Ryensvingen 3 N-0680 Oslo Tel: +47 22576100 Fax: +47 22576130 elektronikk@nortelco.no www.nortelco.no Nortronicom AS Ryensvingen 5 Postboks 33 Manglerud N-0612 Oslo Tel: +47 23 24 29 70 Fax: +47 23 24 29 79 www.nortronicom.no Nässjö Plåtprodukter AB Box 395 571 24 Nässjö Tel: 031-380 740 60 www.npp.se

Kontaktperson: Rickard Elf Produkter och Tjänster: INSTRUMENT. Proxitron AB arbetar med försäljning och service inom elektronikbranschen. Vi samarbetar med en rad ledande internationella tillverkare inom områdena; Klimat/Vibration, EMC, Givare, Komponenter, Högspänning och Elsäkerhet. Våra kunder finns över hela Skandinavien och representerar forskning/utveckling, produktion, universitet och högskolor.

Processbefuktning AB Pilotgatan 17 128 32 Skarpnäck Tel: 08-659 01 55 Fax: 08-659 01 58 www.processbefuktning.se Procurator AB Box 9504 200 39 Malmö Tel: 040-690 30 00 Fax: 040-21 12 09 www.procurator.se Profcon Electronics AB Hjärpholn 18 780 53 Nås Tel: 0281-306 00 Fax: 0281-306 66 www.profcon.se Proxy Electronics AB Box 855 391 28 Kalmar Tel: 0480-49 80 00 Fax: 0480 49 80 10 www.proxyelectronics.com RF Partner AB Flöjelbergsgatan 1 C 431 35 Mölndal Tel: 031-47 51 00 Fax: 031-47 51 21 info@rfpartner.se www.rfpartner.se Rittal Scandinavian AB Månskärsgatan 7 141 71 Huddinge Tel: 08-680 74 08 Fax: 08-680 74 06 www.rittal.se

Rohde & Schwarz Sverige AB Flygfältsgatan 15 128 30 Skarpnäck Tel: 08-605 19 00 Fax: 08-605 19 80 info.sweden@rohdeschwarz. com www.rohde-schwarz.se

PROXITRON AB Box 324 591 24 Motala Tel: 0141-580 00 Fax: 0141-584 95 info@proxitron.se www.proxitron.se

Nohau Solutions AB Derbyvägen 4 212 35 Malmö Tel: 040-59 22 00 Fax: 040-59 22 29 www.nohau.se

Polystar Testsystems AB Mårbackagatan 19 123 43 Farsta Tel: 08-506 006 00 Fax: 08-506 006 01 www.polystartest.com

Ronshield AB Kallforsvägen 27 124 32 Bandhagen Tel: 08-722 71 20 Fax: 08 556 720 56 info@ronshield.se www.ronshield.se Kontaktpersoner: Ronald Brander Produkter och Tjänster: Produkter: Kompletta EMC-mätplatser/hallar, absorbenter, ferriter, vridbord, antenner, antennmaster, TEM-Cell, Strip­lines, EMC-Mätinstrument och system, Audio-video system, fiberoptiska styrningar, EMC-­ Filter, RÖS-Rum, EMP-Skydd/ Filter, Utbildning.

www.electronic.nu – Electronic Environment online

Produkter och Tjänster: Rohde & Schwarz-koncernen med huvudkontor i München utvecklar, tillverkar och marknadsför kommunikations-, IT och test & mätutrustningar samt system med fokus på mobil radiokommunikation, broadcasting, EMC, HF-test, generella instrument, signalspaning och frekvensövervakning. Rohde & Schwarz är Europas största tillverkare av elektronisk test och mätutrustning. Rohde & Schwarz etablerades för över 80 år sedan och har dotterbolag och representanter i över 70 länder. Koncernen har ca 9800 anställda och omsätter årligen ca 1.75 miljarder euro. Ungefär 80 % av omsättningen genereras utanför Tyskland. Rohde & Schwarz Sverige AB är ett helägt dotterbolag i koncernen och ansvarar för hela produktlinjen på den svenska marknaden.


Företagsregister

Electronic Environment #4.2017 Roxtec International AB Box 540 371 23 Karlskrona Tel: 0455-36 67 23 www.roxtec.se RS Components AB Box 21058 200 21 Malmö Tel: 08-445 89 00 Fax:08-687 11 52 www.rsonline.se RTK AB Box 7391 187 15 Täby Tel: 08-510 255 10 Fax: 08-510 255 11 info@rtk.se www.rtk.se RUTRONIK Nordic AB Kista Science Tower Färögatan 33 164 51 Kista Tel: 08-505 549 00 Fax: 08-505 549 50 www.rutronik.se Saab AB, Aeronautics, EMC-labbet Gelbgjutaregatan 2 581 88 Linköping Tel: 013-18 00 00 andreas.naslund@saabgroup.com Saab AB, Surveillance A15 – Compact Antenna Test Range Bergfotsgatan 4 431 35 Mölndal Tel: 031-794 81 78 christian.augustsson@saabgroup.com www.saabgroup.com

Saab AB, Support and Services, EMC-labbet P.O Box 360 S-831 25 Östersund Tel: +46 63 1 560 00 Fax: 063-15 61 99 www.emcinfo.se www.saabgroup.com Contact: Henrik Risemark Products & Services: We offer accredited EMC testing in accordance with most commercial and military standards and methods, including airborne equipment. We can also provide pre-compliance testing and qualified reviews and guidance regarding EMC during product design.

Saab EDS Nettovägen 6 175 88 Järfälla Tel: 08-580 850 00 www.saabgroup.com Scanditest Sverige AB Box 182 184 22 Åkersberga Tel: 08-544 019 56 Fax: 08-540 212 65 www.scanditest.se info@scanditest.se

Scandos AB Varlabergsvägen 24 B 434 91 Kungsbacka Tel: 0300-56 45 30 Fax: 0300-56 45 31 www.scandos.se

Stigab Fågelviksvägen 18 145 53 Norsborg Tel: 08-97 09 90 info@stigab.se www.stigab.se

Schaffner EMC AB Turebergstorg 1 191 86 Sollentuna Tel: 08-579 211 22 Fax: 08-92 96 90 Schroff Skandinavia AB Box 2003 128 21 Skarpnäck Tel: 08-683 61 00

TEBAB, Teknikföretagens Branschgrupper AB Storgatan 5, Box 5510, 114 85 Stockholm Tel +46 8 782 08 08 Tel vx +46 8 782 08 50 www.sees.se SEES är den svenska branschföreningen för miljötålighetsteknik.

Skandinavia AB Box 2003 128 21 Skarpnäck Tel: 08-683 61 00 Turebergstorg 1 191 86 Sollentuna Tel: 08-579 211 22 Fax: 08-92 96 90

SEK Svensk Elstandard Box 1284 164 29 KISTA Tel: 08-444 14 00 sek@elstandard.se www.elstandard.se Shop.elstandard.se Produkter och Tjänster: Du kan genom deltagande i SEK Svensk Elstandard och den nationella och internationella standardiseringen vara med och påverka framtidens standarder samtidigt som ditt företag får en ökad affärsnytta och ökad konkurrenskraft. På SEK Shop, www.elstandard.se/shop, hittar du förutom svensk standard även europeisk och internationell standard inom elområdet. SEK ger även ut SEK Handböcker som förklarar och fördjupar, vägleder och underlättar ditt användande av standarder. Läs mer på www.elstandard.se.

Swentech Utbildning AB Box 180 161 26 Bromma Tel: 08-704 99 88 www.swentech.se

Schurter Nordic AB Sandborgsvägen 50 122 33 Enskede Tel: 08-447 35 60 Fax: 08-605 47 17 www.schurter.se

Swerea KIMAB AB Box 7047 Isafjordsgatan 28 164 40 Kista Tel: 08-440 48 00 elektronik@swerea.se www.swereakimab.se

SEBAB AB Sporregatan 12 213 77 Malmö Tel: 040-601 05 00 Fax: 040-601 05 10 www.sebab.se SGS Fimko AB Mörtnäsvägen 3 (PB 30) 00210 Helsingfors Finland www.sgs.fi

Shortlink AB Stortorget 2 661 42 Säffle Tel: 0533-468 30 Fax: 0533-468 49 info@shortlink.se www.shortlink.se

Technology Marketing Möllersvärdsgatan 5 754 50 Uppsala Tel: 018-18 28 90 Fax: 018-10 70 55 www.technologymarketing.se Tesch System AB Märstavägen 20 193 40 Sigtuna Tel: 08-594 80 900 order@tufvassons.se www.tesch.se

Sims Recycling Solutions AB Karosserigatan 6 641 51 Katrineholm Tel: 0150-36 80 30 www.simsrecycling.se STF Ingenjörsutbildning AB Malmskillnadsgatan 48 Box 1419 111 84 Stockholm Tel: 08-613 82 00 Fax: 08-21 49 60 www.stf.se

Testhouse Nordic AB Österögatan 1 164 40 Kista Landskronavägen 25 A 252 32 Helsingborg Tel: 08-501 260 50 Fax: 08-501 260 54 info@testhouse.se www.testhouse.se

Vanpee AB Karlsbodavägen 39 168 67 Bromma Telefon: 08-445 28 00 www.vanpee.se order@vanpee.se

RISE Elektronik Box 857 501 15 Borås Tel: 010-516 50 00 info@ri.se www.ri.se Kontaktperson: Christer Karlsson Produkter och tjänster: RISE Elektronik (fd SP Sveriges Tekniska Forskningsinstitut) hjälper dig med oberoende kunskap och provning inom elsäkerhet, EMC, radioutrustning, maskinsäkerhet, IP-klassning, funktionssäkerhet samt mekanisk och klimatisk miljötålighet. I laboratorierna sker allt från utvecklingsprovning till ackrediterade prov. Vi ger både öppna och kundspecifika kurser inom flera områden. En omfattande forskning bedrivs för att säkra spetskompetensen i samverkan med industri, akademi och andra forskningsinstitut. Kontaktperson: Christer Karlsson

Weidmüller AB Box 31025 200 49 Malmö Tel: 0771-43 00 44 Fax: 040-37 48 60 www.weidmuller.se Wretom Consilium AB Olof Dalins Väg 16 112 52 Stockholm Tel: 08-559 265 34 info@wretom.se www.wretom.se Würth Elektronik Sweden AB Annelundsgatan 17 C 749 40 Enköping Tel: 0171-41 00 81 eiSos-sweden@we-online.com www.we-online.se Kontaktperson: Martin Danielsson

Yokogawa Measurement Technologies AB Finlandsgatan 52 164 74 Kista Tel: 08-477 19 00 Fax: 08-477 19 99 www.yokogawa.se Österlinds El-Agentur AB Box 96 183 21 Täby Tel: 08-587 088 00 Fax: 08-587 088 02 www.osterlinds.se

Tormatic AS Skreppestad Naringspark N-3261 Larvik Tel: +47 33 16 50 20 Fax: +47 33 16 50 45 www.tormatic.no Trafomo AB Box 412 561 25 Huskvarna Tel: 036-38 95 70 Fax: 036-38 95 79 www.trafomo.se Treotham AB Box 11024 100 61 Stockholm Tel: 08-555 960 00 Fax: 08- 644 22 65 www.treotham.se TRESTON GROUP AB Tumstocksvägen 9 A 187 66 Täby Tel: 08-511 791 60 Fax: 08-511 797 60 Bultgatan 40 B 442 40 Kungälv Tel: 031-23 33 05 Fax: 031-23 33 65 info.se@trestoncom www.treston.com

Trinergi AB Halltorpsvägen 1 702 29 Örebro Tel: 019-18 86 60 Fax: 019-24 00 60 UL International (Sweden) AB An affiliate of Underwriters Laboratories Inc. Stormbyvägen 2-4 163 29 Spånga Tel: 08-795 43 70 Fax: 08-760 03 17 www.ul-europe.com

www.electronic.nu – Electronic Environment online

39


POSTTIDNING B  Returer till: Break a Story Mässans gata 14 412 51 Göteborg

v

EMC-TESTUTRUSTNING RadiPower –Effektmetrar för EMC mätningar, 9kHz-18GHz Radipower är en serie RF-effekthuvuden för mätning inom 9kHz-18GHz. Två modeller täcker området 9(4)kHz-18GHz. Modell RPR2006C, 9kHz-6GHz med option10 mäter från 4kHz som krävs enligt Mil.Std 461, CS-114. Levereras med USB-kabel och programvara för avläsning i en PC. Med interface USB1004A till centralenheten RadiCenter kan 4 st effekthuvuden anslutas och man mäter ut- och reflekterad effekt från 2 st förstärkare.

Modell RPR2006C m.opt.10 RPR2006P RPR3006W RPR2018C

Frekv.område 9kHz-6GHz 4kHz-6GHz 9kHz-6GHz 9kHz-6GHz 80MHz-18GHz

Läshastighet 20-100kSps eller 1MSps 20-100kSps eller 1MSps Burst & Puls WLAN enl. ETSI300328 20-100kSps eller 1MSps

Pris ex. moms 19 640:3 480:25 000:36 000:38 000:-

RadiSense–Laserdrivna probar 4GHz, 6GHz, 10GHz och 18GHz Robusta-tillförlitliga-små och batterifria är egenskaper som krävs för att mäta E-fält i en EMC-hall. De sfäriska modellerna för 6 och 10GHz har en diameter mindre än en halv tändsticka. Den senaste modellen har dessutom 6 sensorer med kalibreringdata lagrade inne i sfären. Levereras med laserkälla, 10 meter fiberkabel och programvara. Modell RSS1004A Opt.10 RSS1006A RSS2010A RSS1006A

Frekv.omr. 9kHz-4GHz 4kHz-4GHz 9kHz-6GHz 9kHz-10GHz 30MHz-18GHz

Mätomr. 1-1000V/m 1-1000V/m 0,5-600V/m 1-600V/m 1-600V/m

Läshastighet Pris 5 gånger/s 5 gånger/s 60 gånger/s 1000 gånger/s 104 000:60 gånger/s 101 000:NYHET: 10GHz – prob Model RSS2010A

Ackrediterad kalibrering enl. ISO17025 som option

EMI-filter för undertryckning av störningar på nätet Dessa filter skyddar Er utrustning och tar bort störningar som ofta förekommer på nätet och skyddsjord. Levereras i utförande för 3A, 10A, 20A och 30A. Enkelt att installera på kontoret, laboratoriet eller i utrustningar. Modell AF = 20-30A Pris från 5 500:Modell AL = 10A Pris 4 380:Modell AP = 3A Pris 2 700:-

Filtermodell GLE04-01 för störningar på skyddsjord. Blockerar högfrekventa signaler och ESD. Monteras i utrustningen. Pris 930:-

Filter för servomotorer

EMI-adapter

Störningar på nätet orsakar fel på servomotorer och frekvensriktare. Framför allt skadar de kullager och motorlindningar. Modell VFD dämpar störningar och förlänger livslängden på utrustningen. Pris 3 600:-

Adaptern isolerar från nätspänningen men släpper igenom högfrekventa signaler för anslutning till oscilloskop eller spektrmanalysator. Ett enkelt och säkert sätt att mäta “common mode” och “differential mode”. Pris 3 900:-

CE-BIT – Box 7055, 187 11 Täby, Sweden – Tel: +46 8-735 75 50 - Fax. +46 8-735 61 65 – E-Mail: info@cebit.se – www.cebit.se