Final Design Project - Hall of Democracy

Page 1

AGE OF GLASS A HALL FOR DEMOCRACY DEVELOPMENT

GENERAL NOTES

STANDARD BUILDING NOTES

COMPLIANCE TO THE BCC

PERFORMANCE/ DESIGN SOLUTIONS

PROPOSED BUILDING

NOTIFY ALL RELEVANT LOCAL AUTHORITY DEPARTMENTS FOR CONNECTION AND SEALING PROCEDURES FOR EXISTING SERVICES AS REQUIRED.

CLASS 5,6 9B BUILDING

CLASS 5,6 9B BUILDING

BUILDING SETBACK

BASEMENT LEVEL HARDSTAND (EXCL. RAMP) CORE/SERVICES END OF TRIP FACILITIES

1990 SQ.M 432 SQ.M 163 SQ.M

BASEMENT GFA TOTAL AREA

2585 SQ.M

GROUND LEVEL PUBLIC HALL TENANCY SPACE 1 RETAIL SPACE RESTAURANT/DINING CORE SERVICES AREA WET AREA

403 SQ.M 54 SQ.M 38 SQ.M 261 SQ.M 124 SQ.M 87 SQ.M

GROUND GFA TOTAL AREA

967 SQ.M

LEVEL ONE LECTURE HALL EXHIBITION SPACE LIBRARY/SERVICES CORE SERVICES AREA WET AREA

195 SQ.M 407 SQ.M 329 SQ.M 124 SQ.M 87 SQ.M

GROUND GFA TOTAL AREA

1142 SQ.M

LEVEL TWO GOVERNMENT TENANCY 1 FUNCTION ROOM AREA TERRACES (NON GFA) CIRCULATION SPACE WET AREA

141 SQ.M 181 SQ.M 323 SQ.M 149 SQ.M 122 SQ.M

LEVEL TWO GFA TOTAL AREA

916 SQ.M

ROOF OPEN ROOF SPACES CORE SERVICES AREA

(NON GFA) (NON GFA)

ROOF GFA TOTAL AREA

N/A

COMPLY WITH ALL RELEVANT SAFETY STANDARDS INCLUDING REQUIREMENTS FOR REMOVAL OF HAZARDOUS MATERIALS.

REFER TO RELEVANT DRAWINGS FOR DETAIL INFORMATION RELATED TO MECHANICAL VENTILATION, HYDRAULIC, ELECTRICAL AND OTHER ENGINEERING ISSUES. REFER TO SURVEY DRAWINGS FOR BUILDING SET OUT.

NOTIFY ALL ADJOINING OWNERS WHEN WORK WILL COMMENCE AND OF THE DURATION OF DEMOLITION WORKS.

40 GEORGE STREET BRISBANE CBD, 4000 DA SUBMISSION

VERIFY THE LOCATION OF EXISTING SERVICES AND PUBLIC UTILITIES PRIOR TO COMMENCEMENT CONTACT THE OVER OF THE PROPERTY FOR ANY CLARIFICATION OF SCOPE OF WORK AS NECESSARY PROPR TO COMMENCEMENT OR DURING DEMOLITION.

REGISTERED PLAN NUMBER: BC735 LOT NO. PARISH: COUNTY:

ENSURE EXISTING STRUCTION REMAIN STRUCTURALLY SOUND ON COMPLETION AND DURING DEMOLITION. ALL DISCREPANCIES TO BE REFERRED IMMEDIATELY TO THE ARCHITECT.

B32444 318°55′ 19" NORTH BRISBANE STANLEY AREA

PROVIDE ALL NECESSARY EXPANSION AND MOVEMENT JOINTS . THE EXTERIOR OF THE BUILDING IS TO BE COMPLETELY WEATHERPROOF AT COMPLETION. TEST AND CERTIFY ALL WARRANTY PAPERS AND MANUALS FOR INSTALLATIONS.

SITE AREA:6491m2

PROVIDE ACCESS FOR PEOPLE WITH DISABILITIES IN ACCORDANCE WITH THE REQUIREMENTS OF THE BCA ALL WORK IS TO COMPLY WITH THE REQUIREMENTS AND BYLAWS OF THE BCA. EXACT POSITION OF SEWER MAIN AND STORM WATER MAIN TO BE LOCATED BY BUILDER PRIOR TO COMMENCEMENT OF CONSTRUCTION. PLOTTED LOCATION INDICATIVE ONLY BASED ON EBIMAP INFORMATION. BUILDING ANY STRUCTURE WITHIN 2M OF COUNCIL SEWER OR STORMEWATER IS NOT PERMITTED UNLESS SPECIALLY APPROVED. IF REQUIRED ALL RETAINING WALL SHALL BE PROVIDED IN STRICT ACCORDANCE WITH ENGINEERS DETAILED DESIGN AND REQUIREMENT.

REFER TO RELEVANT DRAWINGS FOR DETAIL INFORMATION RELATED TO MECHANICAL VENTILATION, HYDRAULIC, ELECTRICAL AND OTHER ENGINEERING ISSUES. REFER TO SURVEY DRAWINGS FOR BUILDING SET OUT.

The proposed building will be set back on ground level at least 1.5m, and allow for overhangs that do not go past toe property boundary

REFER TO CIVIL ENGINEERS DRAWINGS FOR ROAD WORK LEVELS AND ALL OTHER STRUCTURAL WORK.

PUBLIC FOOTPATH REFER TO ENGINEERS DRAWINGS FOR CONCRETE SLABS, FOUNDATION AND FOOTING DETAILS, TIE DOWN DETAILS BEAM SIZES ETC.

George Street is described as a ‘Subtropical Boulevard’ street in BCC CITY PLAN CH4 Fortitude Valley Local plan.

EXCAVATE AS REQUIRED, FALL PLATFORM AWAY FROM BUILDING DRAIN ALL CUTS.

Requires 6m of new minimum public footpath width (table 3 BCC Ch4FV) Adjacent properties provide approximately 4.5m clearance from ground building face (NOT property boundary) to edge of street throughout the building’sfrontage to George and William Street.

LEVELS ARE TO BE CONFIRMED ON SITE. R.C SLABS SHALL BE LAID OVER WATERPROOF MEMBRANE AND OVER 50mm SAND BED POSITION UNDER SLAB TO CURRENT AUSTRALIAN STANDARDS.

In addition to maintaining this consistency with adjoining properties, the footpath will be repaved upon completion of woks, with landscaping, lighting, seating andcity cycle provisions provided.

ALL SLABS HAVE A MINIMUM WORKING TOLERANCE OF +/-3MM PER 3000mm. ALL HANDRAILS AND BALUSTRADES TO COMPLY WITH BCA BY-LAW D.2.16 AND D2.14. STAIRS ARE TO COMPLY WITH BCA BY-LAW D2.14 AND D2.13. CARRY FIRE WALLS UP TO UNDERSIDE OF ROOF SHEETING. MATERIALS AND FORMS OF CONSTRUCTION TO BE IN ACCORDANCE WITH STRUCTURAL ENGINEER’S DRAWINGS AND DETAILS. FIRE WALLS TO BE CONSTRUCTED IN ACCORDANCE WITH BCA BY-LAW C2.7. PROVIDE HEADROOM TO ALL STAIRS AND STAIRWELLS TO COMPLY WITH BCA D1.6. AT ALL TIMES COMPLY WITH BCA AND LOCAL BUILDING AUTHORITY REQUIREMENTS.

COMPLIANCE TO THE NCC

DISCLAIMER

CLASS 5,6 9B BUILDING

THE HARD COPY ACCOMPANYING THE ELECTRONIC DATA IS THE LEGAL TRANSMISSION OF INFORMATION. THE ELECTRONIC DATA ARE ISSUED ONLY FOR CONVENIENCE OF USE.

REFER TO RELEVANT DRAWINGS FOR DETAIL INFORMATION RELATED TO MECHANICAL VENTILATION, HYDRAULIC, ELECTRICAL AND OTHER ENGINEERING ISSUES. REFER TO SURVEY DRAWINGS FOR BUILDING SET OUT.

BUILDER TO SATISFY ALL REQUIRED DA CONDITIONS.

DRAWING LIST Sheet Number

WET AREAS TO COMPLYWITH BCA BY-LAWS F1.7 FLASS ALL PENETRATIONS THROUGH ROOF.

D101 D102 D103 D104 D105 D107 D108 D109 D110 D112 D111 D113 D106 D121 D119 D120 D124 D123 D117 D118 D125 D114 D115 D116 D122 D127 D126

Sheet Name COVER SHEET SITE PLAN BASEMENT PLAN GROUND PLAN LEVEL ONE PLAN LEVEL TWO PLAN ROOF PLAN ELEVATIONS ELEVATIONS SECTION A2 SECTION A1 SECTION B1 LEVEL ONE REFLECTED CEILING PLAN SERVICES CORE PLAN FIRE STAIR DETAIL FIRE STAIR DETAIL SECTION WET AREA ELEVATIONS WET AREA ELEVATIONS DETAILS DETAILS LUXFOR WATER WALL SECTION B2 SECTION C1 SECTION C2 WET AREA FLOORPLAN EVACUTION PLAN MARBLE FACADE DETAIL

Sheet Issue Drawn Approved Date By By 01/25/07 10/09/16 10/10/16 10/10/16 10/10/16 10/10/16 10/10/16 10/11/16 10/11/16 10/11/16 10/11/16 10/11/16 10/11/16 11/07/16 11/07/16 11/07/16 11/08/16 11/08/16 11/08/16 11/10/16 11/10/16 11/14/16 11/14/16 11/14/16 11/14/16 11/15/16 11/15/16

JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB JB Author Author

SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG SG Approver Approver

NO RESPONSIBILITY FOR THE ACCURACY OR FOR ANY CONSEQUENCE RESULTING FROM THE USE ALTERATION OF THIS INFORMATION IS ACCEPTED.

GFA SUMMARY TOTAL BUILDING GFA: ALLOWED GFA:

COPYING OR REPRODUCTION OF THIS DRAWING OR ELECTRONIC DATA WITHOUT THE WRITTEN PERMISSION OF AGV ARCHITECTURE PTY. LTD. IS NOT PERMITTED CONTRACTORS SHALL VERIFY JOB DIMENSIONS BEFORE COMMENCING ANY WORKS.

CHECK ALL DIMENSIONS BEFORE STARTING ON SITE. DRAWING LIST

BCC CITY PLAN CH5 Centre Design Code - P11 A11:1: “ A 3 m wide set back is provided at ground level for Pedestrians, or where a lesser setback exists for adjoining properties, the setback is no less than that of the adjacent property.

GENERAL NOTES

DO NOT SCALE OFF THIS DRAWING - USE FIGURED DIMENSIONS.

FOR ALL DOWN PIPE LOCATIONS REFER TO HYDRAULIC ENGINEERS DRAWINGS.

THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS AND SPECIFICATIONS.

TACTILE INDICATORS TO COMPLY WITH BCA BY-LAW D3.8.

COPYWRITER OF THIS DRAWING AND ALL WORKS EXECUTED FROM SUCH, REMAIN THE PROPERTY OF THE ARCHITECT.

ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH BCA AND RELEVANT STANDARDS AND BY-LAWS. FIRE WALLS TO BE CONSTRUCTED IN ACCORDANCE WITH BCA BY-LAW C2.7. PROVIDE HEADROOM TO ALL STAIRS AND STAIRWELLS TO COMPLY WITH BCA D1.6.

DIMENSIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT, PREPARATION OF SHOP DRAWINGS OR MANUFACTURING, FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALING. VERIFY LOCATION OF EXISTING SERVICES BEFORE COMMENCEMENT. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA, BUILDING ACT 1975 AS AMENDED, STANDARD BUILDING BY-LAWS AND RELEVANT AUSTRALIAN STANDARDS.

CITED STANDARDS: AS 4674-2004 AS 1428.1-2009 AS 2293.1—2005 AS 1668.2-2012 AS 2118.1-2006 AS 1100 AS/NZS 2890.6 2009 AS/NZS 2890.1:2004 AS/NZS 2890.2-2002 AS/NZS 1428.1 2009 AS 1428.2 AS/NZS 1428.4.1:2009

AT ALL TIMES COMPLY WITH BCA AND LOCAL BUILDING AUTHORITY REQUIREMENTS. BUILDER TO SATISFY ALL REQUIRED DA CONDITIONS. CHECK ALL DIMENSIONS BEFORE STARTING ON SITE. AT ALL TIMES COMPLY WITH BCA AND LOCAL BUILDING AUTHORITY REQUIREMENTS. BUILDER TO SATISFY ALL REQUIRED DA CONDITIONS.

PROJECT ADDRESS

CHECK ALL DIMENSIONS BEFORE STARTING ON SITE.

40 GEORGE STREET, BRISBANE, QUEENSLAND, 4000.

WET AREAS TO COMPLY WITH BCA BY-LAWS F1.7 FLASH ALL PENETRATIONS THROUGH ROOF. FOR ALL DOWN PIPE LOCATIONS REFER TO HYDRAULIC ENGINEERS DRAWINGS.

ABBREVIATIONS B BCT BP BEN COL DBR DP ELEC. FD FHR HC HD HR1 HR2 HYD MIR MECH. WC W.S SD SNK SHD SHR TGSI TRD UR

- WASHBASIN - BABY CHANGE TABLE - BARRIER POLE - FIXED BENCH - COLUMN - DISABLE BACK REST - DOWN PIPE - ELECTRICAL RISER - FLOOR DRAIN - FIRE HOSE REEL - HOSE COCK - HAND DRYER - AMBULANT TOLIET HANDRAIL - DISABLE TOLIET HANDRAIL - FIRE HYDRANT - MIRROR - MECHANICAL RISER - WATER CLOSET - WHEEL STOP - SOAP DISPENSER - SINK - SHADING DEVICE - SHOWER - TACTILE INDICTOR - TOILET ROLL DISPENSER - URINAL

AGE OF GLASS HALL FOR DEMOCRACY

COVER SHEET

PROJECT NO#

01

DATE

09/11/2016

DRAWN BY

JB

CHECKED BY

SG

D101

SCALE

N/A NORTH POINT

N/A

CORNER OF ALICE STREET AND GEORGE STREET PERSPECTIVE

LOCATION PLAN N/A