DIRECT ACTING SOLENOID VALVE MICROSOL  2/2, 3/2 - 15 mm

VALVES

Technical Data

• Manifold mounting • Compact design • High flow rate • In excess of 100 – Mio. cycle rate • Up to 3,6 mm orifice

Medium: Air, oxygen, neutral gases (10% to 95% humidity, non condensing), 40 μm filtered

Life expectancy: ≥100 million cycles (except Hit & Hold valves)

Operation: Direct acting 2-way and 3-way valves, normally closed and normally opened

Ambient temperature: -10°C … +50°C Air supply must be dry enough to avoid ice formation at temperatures below +2°C

Operating pressure: see table

Materials

Flow: 6 … 120 l/min at 2 bar at +20°C

Body: PPS

kv factor: 0,15 … 3 (Cv: 0,01 … 0,2)

Seat seals: NBR, FPM

Orifice: 2/2 way valves: 0,5 … 3,6 mm 3/2 way valves: 0,5 … 1,5 mm

Internal parts: Stainless steel, PA 6/6

Response time: 10 … 15 ms Response time measured according to ISO 12238

Models Model

Accessories Operation

284

Orifice Operating kv *1) Power Voltage Manual Seal Dimension Mounting plate with M5 (mm) pressure consumption (V d.c.) override material No. thread — 1 position for (bar) (l/min) (W) *2) 2 ways valve up to 2 mm orifice and 3 ways valve

Electrical connector MPM 9,4 mm industry standard (C192) to mate AMP spade 2,8 x 0,5 mm

Online at www.imi-precision.com

01-211P-036H0+63111+AZN 2/2 NC (Flow direction from 2 » 1) 3,6

0…6

3

12/0.5

24

Without NBR

1

S050.1010

N050.1456

01-311P1011H0+63111+AYZ 3/2 NC

1,1

0 … 10

0,42

2

24

Without NBR

2

S050.1010

N050.1456

01-211P200-H0+13111+AYV 2/2 NC

0,5

0 … 15

0,15

1

24

Without NBR

3

S050.1010

N050.1456

01-211P201-H0+13111+AYV 2/2 NC

0,8

0 … 10

0,4

1

24

Without NBR

3

S050.1010

N050.1456

01-211P202-H0+63111+AYZ 2/2 NC

1,2

0 … 10

0,75

2

24

Without NBR

3

S050.1010

N050.1456

01-211P204-H0+63111+AYZ 2/2 NC

2

0…4

1,3

2

24

Without NBR

3

S050.1010

N050.1456

01-221P200-H0+631A1+AYZ 2/2 NO

0,5

0 … 16

0,15

2

24

Without NBR

4

S050.1010

N050.1456

01-221P202-H0+631A1+AYZ 2/2 NO

1,2

0 … 10

0,75

2

24

Without NBR

4

S050.1010

N050.1456

01-221P204-H0+631A1+AYZ 2/2 NO

2

0…6

1,4

2

24

Without NBR

4

S050.1010

N050.1456

01-311P101-H0+13111+AYV 3/2 NC

0,8

0…8

0,28

1

24

Without NBR

2

S050.1010

N050.1456

01-311P1015H0+63111+AYZ 3/2 NC

1,5

0…6

0,55

2

24

Without NBR

2

S050.1010

N050.1456

01-321P101-H0+631A1+AYZ 3/2 NO

0,8

0 … 10

0,28

2

24

Without NBR

5

S050.1010

N050.1456

01-321P1011H0+631A1+AYZ 3/2 NO

1,1

0…6

0,42

2

24

Without NBR

5

S050.1010

N050.1456

01-321P1015H0+631A1+AYZ 3/2 NO

1,5

0…3

0,55

2

24

Without NBR

5

S050.1010

N050.1456

01-331P1070H0+63111+AYZ 3/2 UNI

0,7

0…6

0,24

2

24

Without NBR

2

S050.1010

N050.1456

01-331P1010H0+63111+AYZ 3/2 UNI

1

0 … 3.5 0,36

2

24

Without NBR

2

S050.1010

N050.1456

01-331P1015H0+63111+AYZ 3/2 UNI

1,5

0…2

2

24

Without NBR

2

S050.1010

N050.1456

Models Available on Request

0,55

*1) Cv - Value in [gal/min] = kv x 0,07; kv for 3/2 way valves represents flow value between ports 2 and 3. *2) Valve models with 2 power consumption values are equipped with ‚Hit & Hold‘ power saving electronic.

3/2 Intrinsically safe solenoid valve - MICROSOL IS Model

Operation

Orifice Operating (mm) pressure (bar)

kv *1)

01-311P-00-H0+H012003+BCC 3/2 NC

0,5

01-311P-00-H0+H012004+BDH 3/2 NC

0,5

01-311P-00-H0+H010014+AWD 3/2 NC 01-311P-00-H0+H010016+AYG 3/2 NC

Accessories

Seal material

Dimension No.

(l/min)

Power Voltage Manual consumption (V d.c.) override (W) *2)

Mounting plate with M5 thread — 1 position for 2 ways valve up to 2 mm orifice and 3 ways valve

Electrical connector MPM 9,4 mm industry standard (C192) to mate AMP spade 2,8 x 0,5 mm

0…7

0,12

0,55

12

With

NBR

6

S050.1010

N050.1456

0…7

0,12

0,70

24

With

NBR

6

S050.1010

N050.1456

0,5

4…7

0,07

0,10

12

With

NBR

7

S050.1010

N050.1456

0,5

4…7

0,07

0,10

24

With

NBR

7

S050.1010

N050.1456

*1) Cv - Value in [gal/min] = kv x 0,07; kv for 3/2 way valves represents flow value between ports 2 and 3. *2) Push only.

For further information, visit www.imi-precision.com and use the new improved search function. If you cannot see the option you require please contact us.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Industrial Automation Solutions Catalogue 2018 by Norgren - Issuu