Industrial Automation Solutions Catalogue 2018

Page 276

3

IN-LINE SOLENOID VALVE 26230, 80107  3/2, 5/2 & 5/3, G1/4 & G1/2

VALVES

• Straight-through flow, high Cv-factor • Standard manual override • Compact design • Easily interchangeable solenoid system

Technical Data

Materials

Medium: Compressed air filtered, lubricated or non-lubricated

Housing: Aluminium

• Maintenance-free, easy to service

Operation: Solenoid, indirectly controlled

• The valves and solenoids (see solenoid table) are ATEX approved

Operating pressure: 1 … 10 bar (see table below)

Pilot flange: Plastic Seat seal: NBR

Nominal size: 6 and 12 mm Flow direction: Fixed Mounting position: Optional, preferably vertical Ambient temperature: -10°C … +50°C Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C

274

Online at www.imi-precision.com

Models Model *

Port size

Function

Operation/return

Nominal size (mm)

Operating pressure min. max. (bar) (bar)

Flow (l/min)

Power consumption (W)

Dimensions No.

8010750 *2)

G1/4

3/2 NC

Solenoid/air

6

1,0

10 *3)

1200

<5

1

8010850 *2)

G1/2

3/2 NC

Solenoid/air

12

1,5

10 *3)

3000

<5

2

8012750 *2)

G1/4

3/2 NO

Solenoid/air

6

1,0

10 *3)

1200

<5

1

8012850 *2)

G1/2

3/2 NO

Solenoid/air

12

1,5

10 *3)

3000

<5

2

8011750

G1/4

3/2 NC

Solenoid/solenoid

6

1,0

10

1200

<5

3

2623000 *2)

G1/4

5/2

Solenoid/air

6

1

10 *3)

1200

<5

5

2623500 *2)

G1/2

5/2

Solenoid/air

12

2

10 *3)

3000

<5

6

2623100

G1/4

5/2

Solenoid/solenoid

6

1

10

1200

<5

7

2623600

G1/2

5/2

Solenoid/solenoid

12

2

10

3000

<5

8

2623200

G1/4

5/3 COE

Solenoid/solenoid

6

3

10

900

<5

9

2623700

G1/2

5/3 COE

Solenoid/solenoid

12

2,5

10

2200

<5

10

2623300

G1/4

5/3 APB

Solenoid/solenoid

6

3

10

900

<5

9

2623800

G1/2

5/3 APB

Solenoid/solenoid

12

2,5

10

2200

<5

10

2623400

G1/4

5/3 COP

Solenoid/solenoid

6

3

10

900

<5

9

* When ordering please indicate solenoid, voltage and current type (frequency). *2) Port 3 is not throttleable. *3) Stagnation pressure at 3 ≤ operating pressure -1 bar. APB = All Ports Blocked,  COE = Centre Open Exhaust,  COP = Centre Open Pressure.

For further information, visit www.imi-precision.com and use the new improved search function. If you cannot see the option you require please contact us.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Industrial Automation Solutions Catalogue 2018 by Norgren - Issuu