Parameter settings Adjusting parameters
Adjustable parameters Transfer Under Way Vodia text: "TransferUnderWay". This parameter is used to activate the Transfer Under Way mode which makes it possible to change the active station while gear is engaged. This function has to be activated in the PCU using the VODIA tool. This will affect all helm stations in the actual drive line, which means up to four possible HCUs (per drive line). Activated for a PCU (MID 787)..
Classified engine Vodia text: "Classified engine".. This parameter is used to change the engine alarm function. The VODIA diagnostic tool can be used to adjust EVC-parameters. This is done with the "Parameter programming" tool in the "Service and maintenance" menu.
Activated for a PCU (MID187)..
VODIA is a Volvo Penta special tool. Complete tool part no. is 3838619.
Volvo Penta Lowspeed
Once you have established contact with the system, you have to choose type of engine and there after the specific ECU (Engine Control Unit) in the drop down menu to show its adjustable parameters. VODIA only shows the adjustable prameters for one ECU at a time and only for an HCU if it is in Service mode. To enter Service mode, press the MULTIFUNCTION BUTTON for at least 5 sec. NOTE! Some of the parameters may require special authorization. More information about handling the VODIA tool is given in the VODIA Operator’s Manual.
There are three adjustable parameters in the Volvo Penta lowspeed function:. - Maximum slip factor for VP Lowspeed . Vodia text: "MaxLowspeedSlip" -
Maximum slip factor for VP trolling. Vodia text: "MaxTrollingSlip"
-
Upper lever limit for slip function at forward Vodia text: "LeverFwdZeroSlip"
-
Upper lever limit for slip function at reverse. Vodia text: "LeverRevZeroSlip"
-
Sets the gear ratio for the reverse gear. Vodia text: "Gear ratio".
-
VP Lowspeed mode at startup. Vodia text: "Low speed default setting"
.
117