ENGLISH
A message will be displayed, light will flash and alarm will sound when engine oil pressure falls below 10psi (0.7bar). Stop the engine when this alarm is activated. Check engine oil levels. Refer to STARTING AND STOPPING THE ENGINE for more information. See the Oil viscosity grade in relation to ambient temperature chart in the back of this manual. See FLUID CAPACITIES in this manual for oil specifications.
REPLACEMENT OF ENGINE OIL AND FILTER The lubricating oil and filters should be changed at regular intervals. See the Planned Maintenance chart for frequency of oil and filter changes. Draining the engine oil
Warm up engine Place an oil collection container under the oil pan, directly beneath the oil drain plug. (Ensure that the container will hold approx. 20 litres.) Unscrew the oil drain plug, then take out the oil level dipstick and remove the fill cap to ease the down flow of the lubrication oil. Once the oil has been drained, replace the drain plug. 27