2 minute read

Air Conditioner (Option)

Next Article
Maintenance Table

Maintenance Table

While the engine and the air conditioner are running, be sure not to touch the rotating objects (fan belt, etc.).

Do not disconnect the piping of the air conditioner carelessly. To replenish refrigerant gas, do not use an improper method.

Touching the air conditioner’s piping is dangerous since it is filled with high-pressure refrigerant gas. Anyone other than qualified persons must not touch the piping.

Maintenance Table

Condenser Check and Cleaning

Refrigerant Level Check

Stop the engine when washing a condenser.

[NOTICE]

◆ Do not use a detergent.

Wash away dirt and dust attached on the fins of condenser with water.

Turn ON the air conditioner switch. While magnet clutch of the compressor is ON, check the sight glass to see how the bubbles are coming out. No bubbles are seen when the amount is proper.

◆ The cover for the inspection port is located upper part on the right of the vehicle.

Refrigerant Piping Connection Check

Outside Air Filter Replacement

Every 2 Years

Replace the filter, taking care of the arrow located on the top of the filter.

In case the extreme amount of oil leaks, perform inspections and maintenance properly to check any gas escaping from the refrigerant piping.

Check any oil leaking from the refrigerant piping connections visually.

Inside Air Filter Check and Cleaning

Every 6 Months

◆ Do not use the organic solvent such as gasoline, trichloroethylene and thinner.

Normally

Blow the air from the clean side.

When it is extremely dirty

Immerse the filter in the warm water that household detergent dissolved. Wash it well, rinse it with clean water, and wait till it dries out completely.

◆ The cover for the inspection port of the inside air filter is located behind the driver's seat.

◆ The cover for the inspection port of the outside air filter is located behind the driver's seat.

V-belt Check ・・・・・Every 3 Months (During the Summer) [NOTICE]

◆ Fasten the belt and nuts after adjustment. Too much tension of the belt will damage the belt and bearings.

◆ Do not put grease on the belt, because the life of the belt will be shortened by slipping.

Check the tension of the belt by following the table below. Check any damage of the belt, too.

Check point

Deflection when Belt tension depressing centergauge of belt by approx. 98 N (10 kg) force

When checking 0.39 to 0.47˝ 44 to 77 lbs. {10 to 12 mm}{196 to 343 N} the new one{5 to 6 mm}{441 to 539 N}

When installing0.2 to 0.24 99 to 121 lbs.

Parts Recommended Regular Replacement

Some components of the air conditioner use parts which wear with time. For safety, such parts must be inspected regularly. The following table gives recommended replacement intervals for the parts. Contact your nearest TADANO distributor or dealer to have these parts inspected at the regular intervals.

Parts recommended regular replacement Interval

Receiver dryer4 years

Blower motor2 years (Differs by usage.)

Electromotive fan motor2,000 hrs (Differs by usage.)