Fuse Replacement [NOTICE]

◆ Be sure to turn OFF the starter switch to prevent a short circuit when replacing a fuse.

◆ Using a fuse with a larger capacity than the rated capacity may cause the wiring or electrical devices to be burned in the event of a short circuit. Always replace a fuse with a fuse of the specified capacity.

Fuses for AML are installed on the inside of the adjustment covers on the top of the AML. When a fuse is burnt out, check for the cause, remove the cause and replace the fuse.

SymbolNameRatingCircuits

CNTL 1, 2 250 V, 2 ASOL 1, 2

CNTL 3, 4 250 V, 2 ASOL 3, 4

CNTL 5, 6 250 V, 2 ASOL 5, 6

F1MAIN250 V, 3 AMain fuse

F2 RLY 1,2 250 V, 3 AFor relay output 1,2

F3 RLY 3,4 250 V, 3 AFor relay output 3,4

F4 RLY 5,6 250 V, 3 AFor relay output 5,6

F5 RLY 7,8 250 V, 3 AFor relay output 7,8

F6SIF 2250 V, 2 A Fuse to SIF2SRC power source output terminal

F7SIF 1250 V, 2 A Fuse to SIF1SRC power source output terminal

◆ It is prohibited to connect new wiring to fuses other than reserve fuses.