SERVICE DATA

PERFORMANCE CRITERIA

2

Hydraulic pump assignment table

P4 P3

P2

P1

2DAA01Z

P1 P2 P3 P4

Left travel Right travel Arm, bucket, auxiliary Charge pressure, pilot pressure

70.0 L/min 70.0 L/min 69.5 L/min 40.5 L/min

Pressure: 34.3 MPa

Test port P1

Pressure: 34.3 MPa

Test port P2

Pressure: 20.6 MPa Pressure: 20.6 MPa Pressure: 20.6 MPa

Test port P3 Test port P3 Test port P3

Pump P1 Left travel

Pump P2 Right travel

Pump P3 Arm Bucket Auxiliary

Pump P4 Charge pressure:Low/ Pressure: 1.6/2.1 MPa high Pilot pressure Pressure: 3.1 MPa

Test port C Test port P4

2-9