Hyster F001 (H1.6-1.8FT, H2.0FTS Europe) Service Manual - PDF DOWNLOAD

Page 1

General Maintenance and Diagnostic Data

Table 9030-03-1. Cummins QSB 3.3L Fault Codes (Continued) DTC Codes

Cummins Fault Codes

Description

108-3

221

Barometric Pressure Sensor Circuit – Voltage Above Normal, or Shorted to High Source

108-4

222

Barometric Pressure Sensor Circuit – Voltage Below Normal, or Shorted to Low Source

110-16

146

Coolant Temperature High - Data Valid but Above Normal Operational Range Moderately Severe Level

111-3

195

Coolant Level Sensor Circuit -Voltage Above Normal, or Shorted to High Source

111-4

196

Coolant Level Sensor Circuit -Voltage Below Normal, or Shorted to Low Source

111-18

197

Coolant Level -Data Valid but Below Normal Operational Range - Moderately Severe Level

157-0

449, 1911

Fuel Pressure High - Data Valid but Above Normal Operational Range – Moderately Severe Level

157-1

2249

Injector Metering Rail 1 Pressure - Data Valid but Below Normal Operational Range -Most Severe Level

157-2

554

Fuel Pressure Sensor Error - Data Erratic, Intermittent, or Incorrect

157-3

451

Injector Metering Rail #1 Pressure Sensor Circuit - Voltage Above Normal, or Shorted to High Source

157-4

452

Injector Metering Rail #1 Pressure Sensor Circuit - Voltage Below Normal, or Shorted to Low Source

157-16

553

Injector Metering Rail #1 Pressure High – Data Valid but Above Normal Operational Range - Moderately Severe Level

157-18

559

Injector Metering Rail #1 Pressure Low – Data Valid but Below Normal Operational Range -Moderately Severe Level

168-16

442

Battery #1 Voltage High - Data Valid but Above Normal Operational Range – Moderately Severe Level

168-18

441

Battery #1 Voltage Low - Data Valid but Below Normal Operational Range – Moderately Severe Level

190-0

234

Engine Speed High - Data Valid but Above Normal Operational Range -Most Severe Level

611-31

757

Electronic Control Module data lost -Condition Exists

612-2

115

Engine Speed/Position Sensor Circuit lost both of two signals from the magnetic pickup sensor - Data Erratic, Intermittent, or incorrect

627-2

434, 1117

Power Lost without Ignition Off - Data Erratic, Intermittent, or Incorrect

629-12

111

Engine Control Module Critical internal failure - Bad intelligent Device or Component

629-12

343

Engine Control Module Warning internal hardware failure - Bad Intelligent Device or Component

629-12

351

Injector Power Supply - Bad Intelligent Device or Component

9030-03-2