Table 7: Controller Area Network (CAN) Functional Detail Function
Activate Beacon/Position/ Work Lights
Inputs/Conditions
• Ignition switch in ON / RUN position. • Beacon / beacon / position / work lights button is pressed.
Outputs/Actions Pressing beacon / position / work lights button once activates the beacon, the rear red position lights, and turns on the left LED in the button.
Malfunction Indicators
Pressing beacon / position / work • Burned out bulb(s). lights button a second time • Ignition switch activates the beacon, the rear malfunction. red position lights, the front work lights, and turns on the right LED • Electrical fault (switch, components, connections in the button. or battery). Pressing beacon / position / work lights button a third time activates • Component / safety interlock system the beacon, the rear red position malfunction. lights, the front and rear work lights, and turns on both LEDs in • Hydraulic system the button. malfunction. Pressing beacon / position / work lights button a fourth time turns off all beacon, position and work lights, and turns off both LEDs in the button.
Self Level Activated when system power is turned on
•
• • Self Level Disable (Cancel)
• •
• Electrical fault (switch, components, connections When the ignition is turned to the or battery). ON/RUN position, the self-level Ignition switch in ON / RUN • Component / safety bypass solenoid is turned off, position. interlock system activating self-level and turning malfunction. off the self level cancel indicator. • Hydraulic system malfunction. Self-level bypass solenoid is turned on (self-level is turned off) and the self-leveling cancel indicator is turned on. Repeated • Electrical fault (switch, Ignition switch in ON / RUN pressing of self-leveling cancel position. components, connections button on the control keypad or battery). Seat switch CLOSED (seat toggles self-level, and the selfoccupied). level cancel indicator light, on/off. • Component/safety interlock system Restraint bar switch CLOSED Self-leveling is reset to ON when malfunction. (restraint bar down). system power is turned off. • Hydraulic system Self-leveling cancel button is NOTE: When the self-level malfunction. pressed. cancel indicator light is ON selfleveling is OFF. Resets when engine stopped.
168
50950421/A1218
PRINTED IN USA