Maintenance - Maintenance schedule Every 1000 hours of operation Refer to the contents to find the page number of the sections referred to ! Pos. in fig

Action

Comment

4

Clean the outside/inside of the radiator core

In dusty environments, as necessary

2

Check lubrication on controls and joints

Lubricate if necessary

5

Check the tension and condition of the fan belt

Replace if necessary

7

Replace the air cleaner filter element, check that hoses and connectors are tight

6

Change the fuel filter

Refer to the engine manual

6

Change the engine oil and oil filter

Refer to the engine manual

4

Check coolant freezing point

Change the coolant every other year

16

Check the oil level in the drums

13

Check the hydraulic reservoir cover/breather

12

Change hydraulic fluid filter

6

Check the engine valve clearances

Refer to the engine manual

5

Replace fan belt

Refer to the engine manual

Check the belt tension on the hydraulic vibration and steering pump drive belt