CLAAS Arion 430-410 Diagnostics Repair Manual - PDF DOWNLOAD

Page 10

Error codes

List of error codes Error code

Native code

Sender module

Id75C0h

301

TR1 (A57-1)

Designation

Inconsistent current measurements obtained on the forward gear solenoid valve.

Cause/System response

Comment/Solution

Audio warning:: No.

Check:

"ISC" reset requested: No.

– The "Auto 5" module using tool n° 60 05 033 249, and change if required.

A different value is received from each of the two measuring points on the return. The "Auto 5" working with the estimated current.

Id75C1h

302

TR1 (A57-1)

Inconsistent current measurements obtained on the reverse gear solenoid valve. A different value is received from each of the two measuring points on the return. The "Auto 5" working with the estimated current.

Id75C2h

TR1 (A57-1)

Supply voltage measured on the Audio warning:: Yes. forward gear solenoid valve "ISC" reset requested: Yes. when the driver is not controlled (setpoint PWM = 0).

Id75C3h

304

TR1 (A57-1)

Supply voltage measured on the reverse gear solenoid valve when the driver is not controlled (setpoint PWM = 0).

Id75C4h

305

TR1 (A57-1)

Actual current measured on the return of the forward gear solenoid valve is too high relative to the setpoint.

Id75C5h

Id75C6h

Id75C7h

10

303

306

307

308

TR1 (A57-1)

TR1 (A57-1)

TR1 (A57-1)

Actual current measured on the return of the reverse gear solenoid valve is too high relative to the setpoint.

The current consumed by the forward gear solenoid valve is greater than 1,4 A (maximum allowable).

The current consumed by the reverse gear solenoid valve is greater than 1,4 A (maximum allowable).

Arion 430-410 – 04.2010 – GB

Check: – For a possible 12 V short circuit on the solenoid valve power supply harness. – The "Auto 5" module using tool n° 60 05 033 249, and change if required.

Check: – For a possible 12 V short circuit on the solenoid valve power supply harness. – The resistance of the solenoid valve winding. – The "Auto 5" module using tool n° 60 05 033 249, and change if required.

Check: – The solenoid valve if 301/302 are not shown. – For a possible 12 V short circuit on the solenoid valve power supply harness. – The resistance of the solenoid valve winding. – The "Auto 5" module using tool n° 60 05 033 249, and change if required.