1 minute read
Initiate an auto TCC adjacent group
WARNING
Mine safety procedures in regards to shield movement MUST be observed.
1. Press to select the TCC operation in Batch group.
2. To select the neighbour group of shields you want the function to operate, push
or . The PMCR display will now show:
3. Using the key, the operator can toggle between the operating modes (STAG,
SEQ & RAND).
STAG = TCC’s will operate in the Stagger Sequence. (See TCC Stagger section) SEQU = TCC’s will operate in sequence across the selected shields in the direction specified. (See TCC Sequential section) RAND = TCC’s will operate randomly across the selected shields. (See TCC Random section)
3. Using the key, the operator can toggle between the directions that the group function will operate.
1. Press the key to begin the TCC batch operation.
Press the key to stop the TCC group at anytime. This will stop all automatic functions on the face.
Press the key and then to stop TCC’s in individual shields without stopping automatic functions in other shields.
Operating Mode Direction
TCC: SEQU 34 < 30
r2 c100 s100 SA-Idle
NOTICE
When using the STOP key to stop a TCC group any shields that are currently performing a TCC will park its caving shield and slide first.