1 minute read

Initiate a rear AFC advance adjacent group

WARNING

Mine safety procedures in regards to shield movement MUST be observed.

1. Press

2. Select which side you want the function to operate by pressing either or

The PMC-R display shows that the Rear Bank Pull will start at Shield 35 and move in the direction of Shield 54.

3. Pressing , the operator can toggle between the operating modes (ALL, SNAKE).

All =all Shields will attempt to RCP until they reach their target stroke. Snake = The Rear AFC will pull to form a snake.

4. Pressing , the operator can toggle between the directions that the group function will operate.

RCP: SNAKE 54 < r2 c100 s100 SA-Idle

NOTICE

The default direction assumes that when snake mode is selected the operator wishes to bring the snake towards him.

5. Press to begin the Rear AFC advance.

The Shields will pull the Rear AFC in the group range to the target stroke.

Press to stop the Rear Conveyor Pull anytime.