Cat Feeder Breaker FBL-10 LHDUtility Operator’s Manual (1)

Page 77

BI620122

Operator’s Manual

Section

20

Attaching Attachments 1. 2. 3. 4. 5. 6.

Ensure the PTO lines to the lock cylinder are connected. Check the RAS locking tongue is retracted. Drive the machine toward the attachment, roll the RAS back plate forward and engage the upper cradle of the attachment back plate with the top lip of the RAS back plate. Roll the RAS back plate back fully and engage the RAS lock tongue in the RAS back plate by pulling the RAS Pilot Lock Cylinder Release Button. Select neutral, apply the park brake and raise the lift arms and attachment 1200 mm 1500 mm above the ground. Exit the machine and visually inspect the RAS lock tongue is fully engaged into the attachment back plate. The operator should always exit the machine and check for engagement before using the attachment.

Do not stand underneath the raised lift arms.

Never walk under the attachment or lift arms.

Top lip of the RAS back plate Attachment Upper Cradle

ATTACHMENT BACK PLATE

RAS BACK PLATE

The lift arms function and motion test on the raise/lower and tilt forward/back needs to be carried out after connecting an attachment.

Rev. 0

FBL-10 LHD/Utility Serial No. 80042

71