BI017744
OPERATING INSTRUCTIONS RH 340 Operation
Assemblies resp. Measuring device reservoirs Cooling system reservoir
Level indicator (4, Fig. 2-70:) Stop filling when the level indicator indicates maximum filling level. (see chapter "Cooling system - Cooling liquid").
Grease container BCS display (2, Fig. 2-71:) – cental lubricating system
Fig. 2-70:
Remarks
BCS gives a warning if the grease container is nearly empty. Switch on the display system (optional) with the toggle switch (23, Fig. 2-72:), indicator lamp (22) comes on. Stop filling when the grease container is full, the indicator lamp (34) lights up. On completion of filling, switch the display system off again with the toggle switch (23), indicator lamp (22) is off.
Fig. 2-72:
Fig. 2-71:
2-62