BI017744
OPERATING INSTRUCTIONS RH 340 Inspection and servicing
Plan A - after every 250 OH (at 250, 750, 1250 ... OH)
Plan B - after every 500 OH (at 500, 1500, 2500 ... OH)
Plan C - after every 1000 OH (at 1000, 2000, 3000, 4000 ... OH)
Plan D - after every 5000 OH (at 5000, 15000, 25000 ... OH)
Plan E - after every 10000 OH (at 10000, 20000, 30000, ... OH) Page 5 of 7 Location
Servicing work
Quant. / No.
Pump transfer gearbox - Breather filter
Plan Plan Plan Plan Plan A
Carry out oil analysis
2
Change oil
2
12
Clean
2x1
B
C
D
E
12
- Pre-chamber
Change oil
2x5
- Breather filter
Clean
2x1
Oil filter
Check for contamination and damage
2x1
Replace
2x1
Slewing gearbox Travel gearbox
- Magnetic rod Pre-chambers
Carry out oil analysis
4
Change oil
4
12
Carry out oil analysis
2
Check oil level
2
12
Change oil
2
Clean
2x1
Check oil level
2x1 12
Change oil
2x1
- Magnetic rod
Clean
2x1
Brake chambers
Check oil level
2x2 2x2
Breather filter
Clean / replace
2x3
Slewing ring
Check grease filling
Gearing / pinion
Check condition
Fastening screws (slewing ring, undercarriage and superstructure)
Check for tightness (see Technical Handbook)
12
12
Change oil
1
see “Refilling quantities – Oil“ table
BA RH340(3 720 350.01)-EN
3-23