Cat 416C 426C & 436C Backhoe Loader Electrical System Schematic Manual - PDF DOWNLOAD

Page 1

Wire Number

Wire Color

101

RD

102

Wire Description Wire Number

Wire Color

Bat (+)

508

PU

Radio Speaker - Left

BU

Hd Lmp

509

WH

Radio Speaker - Left (Common)

104

YL

Aux Ckt

511

BR

Radio Speaker - Right

105

BR

Key Sw

512

GN

Radio Speaker - Right (Common)

110

GN

Aux Ckt

513

OR

A/C Compressor/Refrigerant Press. Sw

111

YL

Aux Ckt

515

GY

Blower Motor (Hi)

112

PU

Main Power Rly Output

516

GN

Blower Motor (Medium)

113

OR

Opr Mon Panel B+ Switched

517

BU

Blower Motor (Lo)

115

PK

Aux Ckt

520

WH

Opr A/C Sw to Thermostat/Fuse

116

BR

Aux Ckt

521

YL

A/C Sw to Refrinerant Sw

118

GY

Aux Ckt

522

WH

A/C Clutch to Thermostat Sw

119

PK

Aux Ckt

536

WH

Hazard Sw to Turn Sw

121

YL

Bckp Alarm to Lamp

537

GN

Turn Signal Sw to Flasher

122

BU

Aux Ckt

552

WH

Four Wheel Drive Sol

123

WH

Aux Ckt

564

GY

Rear Wiper Interrupt Sw to Wiper Sw

124

GN

A/C

568

GN

Warning Buzzer to Diodes

128

PK

Aux Ckt

C558

BU

Front Wiper Switch Jumper

130

GN

Aux Ckt

C559

GN

Rear Wiper Switch Jumper

140

BU

Aux Ckt

143

BR

Aux Ckt

602

WH

Dome Lamp

144

GN

Aux Ckt

603

PK

Rotary Beacon

157

YL

Aux Ckt

604

OR

Stop Lamp

161

PK

Aux Ckt

605

YL

Turn Lamp - Left

170

YL

Aux Ckt

606

GY

Turn Lamp - Right

194

GN

Aux Ckt

607

PK

Flood Lamp - Front

197

GN

Aux Ckt

608

GN

Flood Lamp - Rear

198

PK

Aux Ckt

614

PU

Park/Tail/Dash Lamp

620

WH

Flood Lamp - Front (Eng. Flood Lamp)

630

GY

Flood Lamp Rear (Attach)

Description Power Circuits

SENR1212-01 January 1998

Description Accessory Circuits (Continued)

Related Electrical Service Manuals Title

Part No.

Lighting Circuits

Ground Circuits 200

BK

Main Chassis

201

BK

Opr Mon Panel CMS

202

BK

XMSN Ctrl

303

BR

Key Sw Acc Position

304

WH

306

Form Number

Axle, Differential, and Brakes (All Wheel Steer)

SENR1205

Resistor, Sender and Solenoid Specifications Component Description

Resistance (Ohms)¹

3E-9362

A/C Relay, Accy, Cab, Lamp Test, Main, Start

90 ± 9

3E-7572

Relay - Left/Right Steer, Shutoff

7T-3828

Resistor - A/C Blower

3E-8622

Solenoid - Shutoff, Valve Gp

10.5

129-4531

Solenoid - Lock

10.5

3E-7507

Solenoid - Front Drive

113-5320

Solenoid - Circle Steer, Left Steer, Right Steer

8.5

3E-8620

Solenoid - Aux Detent, Bucket Position

32.1

3E-1907

A/C Clutch

160 Overall - 1.0 ± .1 Tap - .5 ± .05

7.7 ± .77

3.5 ± .15

¹ At room temperature unless otherwise noted.

Control Circuits 752

YL

XMSN Shift Sol No.2

754

BU

XMSN Shift Sol No.3 or 1

762

YL

Bucket Positioner Sol Sw

Starter Rly No.1 Output

766

GN

XMSN Disconnect Sol

GN

Starter Rly Coil to Neut Start Sw or Key Sw

779

WH

Coupler Engage Sol

307

OR

Key Sw to Neut Start Sw

C720

BU

Relay Interlock

308

YL

Main Power Rly Coil

E764

OR

Sol 1 to Sw 1

309

GY

Alt Regulator Term.

G726

GY

Relay to Sol

310

PU

Start Aid Sw to Start Aid Sol

G742

GN

Relay Coil to Diode

321

BR

Bckp Alarm Lamp Travel Alarm

G743

OR

Relay Coil to Diode

322

GY

Warning Horn (Forward)

G789

BR

Mode Sw to Press Sw

G795

OR

AWS Mode Sw to Rear Steer Sw

Basic Machine Circuits

Monitoring Circuits

Part No.

Off Machine Switch Specification

Function

6T-2665

Engine Coolant Temperature

114-5333

Refrigerant Pressure (AC)

Actuate

Deactuate

Contact Position

107.2 ± 2.8°C (225 ± 5°F)

93°C MIN (196°F MIN)

Normally Open

275 to 1750 kPa ¹ (40 to 255 psi)

— —

Normally Open ²

128-5091

Pressure

551 kPa (36.3 psi)

344 kPa ± 20 kPa (49.9 psi ± 2.9 psi)

Normally Closed (Contacts A-C Below Deactuation Press) Normally Open (Contacts A-C Below Deactuation Press)

9X-5446

Thermo

.25 Nm to .43 Nm (.19 ft lb to.32ftlb)

— —

Normally Open

405

GY

Opr Mon Oil Press. (Lo Setting)

G796

YL

AWS Mode Sw to Rear Steer Sw

406

PU

Opr Mon Coolant Temp

G797

BU

Sw to Relay Coil

¹ A hysteresis band exists: with increasing pressure the closed condition can be maintained up to 2800 kpa (405 psi), with decreasing pressure the closed condition can be maintained down to 170 kpa (25psi).

415

GN

Opr Mon Test Sw

G798

PU

Sw to Relay Coil

² Contact postion at the contacts of the harness connector.

419

YL

Opr Mon Parking Brake

H767

BR

AWS Sol Gnd

429

YL

Opr Mon Brake Oil Temp

H768

BR

AWS Sol Gnd

441

OR

Eng Coolant Temp Gauge

H769

BR

AWS Sol Gnd

443

YL

Power Train Temp Gauge

H770

BR

AWS Sol Gnd

447

PK

Fuel Level Gauge

F871

PU

L/S Strg Jumper

450

YL

Tach Sender(+)

F872

BU

R/S Strg Jumper

483

BR

Brake Fluid Level

F874

PK

Switch to Timer Input

F877

WH

Switch to Relay 1

BR

XMSN Sol No 2 Return

Accessory Circuits 500

BR

Wiper - Front (Park)

922

501

GN

Wiper - Front (Lo)

923

GY

XMSN Sol No 3 or 1 Return

502

OR

Wiper - Front (Hi)

C993

WH

Neutral Switch

503

BR

Wiper - Rear (Park)

L998

OR

Aux Hyd Sol B

504

YL

Wiper - Rear (Lo)

L999

GN

Aux Hyd Sol C

505

BU

Wiper - Rear (Hi)

M913

PU

Diode to Indicator Lamp

M968

BU

Coupler Switch Interconnect

416C, 426C, and 436C Backhoe Loader Electrical System 416C: 4ZN1-5634 1AR1-648 1KR1-415 1WR1-2946

426C: 6XN1-1244 1CR1-363 1MR1-455 1YR1-516

436C: 8TN1-390 1FR1-415 1PR1-597 2AR1-603

Harness And Wire Electrical Schematic Symbols

Alarm - Backup Alarm - Park Brake Alternator Arc Suppressor (A/C) Arc Suppressor.A (AWS) Arc Suppressor.D (AWS)

Connector Location

Schematic Location

Machine Location

CONN 1

B-11

A

CONN 2

C-11

A

CONN 3

C-11

A

CONN 4

B-10

D

CONN 5

B-10

D

CONN 6

C-10

CONN 7

C-9

CONN 8

Connector Number

Component Location Machine Location 1

Component Service Meter

Schematic Location C-12

Machine Location A

B-14

A

Solenoid - A/C Clutch

H-11

15

D-2

2

Solenoid - Aux Detent

A-5

16

G-11

9

Solenoid - Bucket Position

A-7

16

I-4

B

Solenoid - Circle Steer

H-6

14

I-5

B

Solenoid - Engine Shutdown

E-2

18

Battery

C-2

3

Solenoid - Front Drive

E-3

19

Breaker - Running Lamp

F-8

A

Solenoid - Left Steer

H-6

14

Coil - Start Aid

D-3

10

Solenoid - Lock

H-6

14

Control - Shuttle

D-6

F

Solenoid - Right Steer

G-6

14

Control Gp - Electronic

C-14

A

Solenoid - Shutoff

H-6

14

Diode Assembly (AWS)

G-2

B

Starter

C-3

20

Flasher

F-8

B

Switch - A/C Blower

H-11

A

Fuses

E-9, E-8

E

Switch - Aux Coupler

B-4

B

Fuses

1-9, 1-8

D

Switch - Aux Front Floods

F-10

D

Fuses

E-12, F-12

D

Switch - Aux Rear Floods

F-9

D

Gauge - AWS Position

H-2

B

Switch - AWD

D-4

B

D

Gauge - Converter Temp

B-13

A

Switch - AWS Mode Select

I-2

B

B

Gauge - Coolant Temp

B-12

A

Switch - Beacon

E-10

D

C-8

B

CONN 9

C-8

B

Gauge - Fuel Level

C-13

A

Switch - Brake Fluid Level

C-3

21

CONN 10

C-7

B

Ground - Engine

F-3

11

Switch - Coolant

E-3

12

CONN 11

D-6

B

Horn - Forward

B-3

5

Switch - Coupler

C-4

B

CONN 12

E-6

B

Lamp - Beacon

A-11

6

Switch - Engine Oil Pressure

E-3

22

CONN 13

E-6

B

Lamp - Dome

G-11

C

Switch - Front Floods

G-10

D

CONN 14

A-4

19

Lamp - Indicator

I-3

A

Switch - Front Wiper

D-10

D

CONN 15

B-4

19

Lightbar

D-13

A

Switch - Hazard

E-4

B

CONN 16

B-4

19

CONN 17

C-4

19

Lightbar - Action

E-4

B

Switch - Heater

A-13

A

CONN 18

H-5

23

Motor - A/C Blower

H-13

7

Switch - Horn

B-4

B

CONN 19

H-4

19

Motor - Fan Assembly

E-14

8

Switch - Orops Aux Front Floods

H-7

D

CONN 20

I-4

19

Motor - Front Wiper

F-5

C

Switch - Orops Beacon

G-7

D

CONN 21

H-2

B

Motor - Rear Wiper

D-14

4

Switch - Orops Front Floods

I-7

D

CONN 22

H-2

B

Radio

H-14

C

Switch - Orops Rear Floods

G-7

D

Relay - A/C

F-7

B

Switch - Park Brake

A-5

A

Relay - Accessory

E-7

E

Switch - Rear Floods

E-10

D

Relay - Cab

D-7

E

Switch - Rear Steer

I-5

B

Relay - Lamp Test

D-12

A

Switch - Rear Wiper

C-10

D

The connectors shown in this chart are for harness to harness connectors. Connectors that join a harness to a component are generally located at or near the component. See the Component Location Chart.

Relay - Left Steer

H-1

B

Switch - Refrigerant

Relay - Main

E-7

E

Switch - RTD (Bucket Positioner)

H-11

9

I-11

13

Relay - Right Steer

H-1

B

Switch - Start

B-14

A

Relay - Shutoff

H-1

B

Switch - Start Aid

C-14

A

Relay - Start

D-7

E

Switch - Thermo

G-12

B

Resistor - A/C Blower

H-12

A

Switch - Turn Signal

E-4

B

Sender - Converter

F-3

11

Switch - XMSN Neutral

C-3

23

Sender - Coolant

D-3

12

Switch - XMSN Neutral

I-5

23

Sender - Fuel

F-4

13

Switch - XMSN Neutral Lock

D-4

B

Sensor - Rear Steering Position

G-6

14

Tachometer

C-13

A

Sensor - RTD (Bucket Positioner)

I-12

17

Machine location are repeated for components located close together A = Operator Compartment - Right Console

D = Operator Compartment - Right Overhead Console

B = Operator Compartment - Front Dash

E = Operator Compartment - Steering Column Top Panel

C = Operator Compartment - Front Overhead Console

F = Operator Compartment

1 Receptacle

Plug 13

16

4 7

14

6

1

F

C

23

E

B

21 8

22 10

12

20

2

5

* C-C4* AG-C3 130-6795 130-6795

17

D

Wire, Cable, or Harness Assembly Identification

Pin or Socket Number

9

15

18

11

24 A

3

Pin

D

* Harness identification letter(s) and a serializing code. The "C" stands for connector and the number indicates which connector in the harness.

C

1

E

B

14

13

11

17

20

19 16

Flow Symbol

Harness identification code This example indicates wire 32 in harness "L'.

Normally closed switch that is open due to an applied condition, and will close again with a specific decrease in that condition.

200-L32 BK-14

2 Circuit Number Identification

Wire Color

Normally closed switch that will open with an increase of a specific condition.

Wire Gauge

The circle indicates that the component has screw terminals and a wire can be disconnected from it.

Electrical Schematic Symbols And Definitions

8 24

Level Symbol

Normally open switch that is closed due to an applied condition, and will open again with a specific decrease in that condition.

21

FUSE - A component in an electrical circuit that will open the circuit if too much current flows through it.

A

1

Temperature Symbol

Normally open switch that will close with an increase of a specific condition (temp-press-etc.).

4 F

T

Pressure Symbol

9X-1123

Socket

Single Wire Connector 6

L-C12* 3E-5179

AG-C4* 111-7898 325-A135 PK-14

7

Component Part Number

2

19

Typical representation of a Sure-Seal connector. The plug and receptacle contain both pins and sockets.

Typical representation of a Deutsch connector. The plug contains all sockets and the receptacle contains all pins.

L-C12 * 3E-5179

AG-C4 * 111-7898

Electrical Schematic Symbols And Definitions

1 2

1 2

Part Numbers For Connector Assembly

325-L25 PK-14

Component

Schematic Location B-15

Printed in U.S.A.

© 1998 Caterpillar All Rights Reserved

10

18 22

2

12 5 15

REED SWITCH - A switch whose contacts are controlled by a magnet. A magnet closes the contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.

9

23 3

D74859

Machine Harness Connector And Component Locations

T

SENDER - A component that is used with a temperature or pressure gauge. The sender measures the temperature or pressure. Its resistance changes to give an indication to the gauge of the temperature or pressure. RELAY (Magnetic Switch) - A relay is an electrical component that is activated by electricity. It has a coil that makes an electromagnet when current flows through it. The electromagnet can open or close the switch part of the relay. CIRCUIT BREAKER (C/B) - A component in an electrical circuit that will open the circuit if too much current flows through it. This does not destroy the circuit breaker and it can be reset to become part of the circuit again. SOLENOID - A solenoid is an electrical component that is activated by electricity. It has a coil that makes an electromagnet when current flows through it. The electromagnet can open or close a valve or move a piece of metal that can do work.

No circle indicates that the wire cannot be disconnected from the component.

This indicates that the component has a wire connected to it that is connected to ground.

This indicates that the component does not have a wire connected to ground. It is grounded by being fastened to the machine.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.