2 minute read
Technical Service Data
F-code Section C-code
PS M2.0 Technical Service Data
Version no T-code
000 HMX,RMX
MODEL
RMX HMX
DRIVE MOTOR
Type Shunt wound Shunt wound Power 1.8 hp. 1.8 hp. Duty factor 60 min. 60 min. Minimum brush length 0.62 in. 0.62 in. Minimum commutator diameter 2.80 in. 2.80 in.
Minimum brush spring tension 40 oz. 40 oz. Part no 12 Volt - 302112-000 24 Volt - 305880-000 305880-000
TRANSMISSION/GEAR
Type Vertical Motor spiral-bevel output Gear ratio 22:1 14.8:1
Oil volume About 1 Quart About 1 Quart Normal temperature SAE 80W90 SAE 80W90 < +5oF-15°C ATF ATF
WHEELS
Drive wheel 10.5 in. x 5 in. x 6.5 in.10.5 in. x 5 in. x 6.5 in.
Drive wheel weight without load with battery lb lb Drive wheel weight with rated load and battery lb lb Torque axle nut 250 ft-lb 250 ft-lb Load wheel 3¼ in. x 6 in. 3¼ in. x 6 in.
Load wheel weight with rated load, lb lb lb
F-code Section C-code
PS M2.0 Technical Service Data
Version no T-code
000 HMX,RMX
HYDRAULIC UNIT MODEL
RMX HMX
Power 12 Volt 24 Volt 24 Volt
Revolutions/min at work pressure 2200 rpm. 2200 rpm. Duty factor 20% on 5 min. cycles 20% on 5 min. cycles Minimum brush length 0.25 in. 0.25 in. Minimum commutator diameter 1.5 in. 1.5 in.
Minimum brush spring tension 32-40 oz. 32-40 oz. Motor part number 12 Volt - 301821-000 24 Volt - 301822-000 301822-000
Relief pressure 4000 psi 4000 psi Pump flow 0.8 cc 0.8 cc Tank volume About 1 quart About 1 quart Normal temperature Sunoco TH Sunoco TH < -10°F - 23°C Texaco 15 Texaco 15
FUSES
Circuit breaker 12 Volt - 150 Amp 24 Volt - 80 Amp 24 Volt - 80 Amp Control circuit 12 Amp 12 Amp
BATTERIES
Dimension W x L x H 31¾ in. x 8c in. 31¾ in. x 13e in. 31¾ in. x 8c in. 31¾ in. x 13e in.
Capacity (Min./Max. Amp-hrs.) 12 Volt - 375/765 24 Volt - 255/660 24 Volt - 255/660
Weight (Minimum) 400 lbs. 400 lbs.
DRIVING SPEEDS MODEL
F-code Section C-code
PS M2.0 Technical Service Data
Version no T-code
000 HMX,RMX
RMX HMX
Without load 3.7 mph 8.0 mph With rated load 2.3 mph RMX50 2.6 mph RMX65 2.4 mph RMX80 6.0 mph HMX65 5.0 mph HMX80
LIFTING/LOWERING TIME
Lift without load
Lift with rated load
Lower without load, electrical valve Lower with rated load, electrical valve
CURRENT CONSUMPTION
Driving without load 12 Volt - 75 Amp 24 Volt - 30 Amp 24 Volt - 30 Amp
Driving with rated load Lifting without load Lifting with rated load 12 Volt - 200 Amp 24 Volt - 115 Amp 24 Volt - 115 Amp
NOTE! Performance may vary up to -10% due to motor and system efficiency tolerance. The performance shown represents nominal values obtained under typical operating conditions. NOTE! These products and specifications are subject to change without notice.
F-code Section C-code
PS M2.0 Technical Service Data
Version no T-code