2 minute read

Technical Service Data

Next Article
Assembly

Assembly

F-code Section C-code

PS M2.0 Technical Service Data

Version no T-code

000 HMX,RMX

MODEL

RMX HMX

DRIVE MOTOR

Type Shunt wound Shunt wound Power 1.8 hp. 1.8 hp. Duty factor 60 min. 60 min. Minimum brush length 0.62 in. 0.62 in. Minimum commutator diameter 2.80 in. 2.80 in.

Minimum brush spring tension 40 oz. 40 oz. Part no 12 Volt - 302112-000 24 Volt - 305880-000 305880-000

TRANSMISSION/GEAR

Type Vertical Motor spiral-bevel output Gear ratio 22:1 14.8:1

Oil volume About 1 Quart About 1 Quart Normal temperature SAE 80W90 SAE 80W90 < +5oF-15°C ATF ATF

WHEELS

Drive wheel 10.5 in. x 5 in. x 6.5 in.10.5 in. x 5 in. x 6.5 in.

Drive wheel weight without load with battery lb lb Drive wheel weight with rated load and battery lb lb Torque axle nut 250 ft-lb 250 ft-lb Load wheel 3¼ in. x 6 in. 3¼ in. x 6 in.

Load wheel weight with rated load, lb lb lb

F-code Section C-code

PS M2.0 Technical Service Data

Version no T-code

000 HMX,RMX

HYDRAULIC UNIT MODEL

RMX HMX

Power 12 Volt 24 Volt 24 Volt

Revolutions/min at work pressure 2200 rpm. 2200 rpm. Duty factor 20% on 5 min. cycles 20% on 5 min. cycles Minimum brush length 0.25 in. 0.25 in. Minimum commutator diameter 1.5 in. 1.5 in.

Minimum brush spring tension 32-40 oz. 32-40 oz. Motor part number 12 Volt - 301821-000 24 Volt - 301822-000 301822-000

Relief pressure 4000 psi 4000 psi Pump flow 0.8 cc 0.8 cc Tank volume About 1 quart About 1 quart Normal temperature Sunoco TH Sunoco TH < -10°F - 23°C Texaco 15 Texaco 15

FUSES

Circuit breaker 12 Volt - 150 Amp 24 Volt - 80 Amp 24 Volt - 80 Amp Control circuit 12 Amp 12 Amp

BATTERIES

Dimension W x L x H 31¾ in. x 8c in. 31¾ in. x 13e in. 31¾ in. x 8c in. 31¾ in. x 13e in.

Capacity (Min./Max. Amp-hrs.) 12 Volt - 375/765 24 Volt - 255/660 24 Volt - 255/660

Weight (Minimum) 400 lbs. 400 lbs.

DRIVING SPEEDS MODEL

F-code Section C-code

PS M2.0 Technical Service Data

Version no T-code

000 HMX,RMX

RMX HMX

Without load 3.7 mph 8.0 mph With rated load 2.3 mph RMX50 2.6 mph RMX65 2.4 mph RMX80 6.0 mph HMX65 5.0 mph HMX80

LIFTING/LOWERING TIME

Lift without load

Lift with rated load

Lower without load, electrical valve Lower with rated load, electrical valve

CURRENT CONSUMPTION

Driving without load 12 Volt - 75 Amp 24 Volt - 30 Amp 24 Volt - 30 Amp

Driving with rated load Lifting without load Lifting with rated load 12 Volt - 200 Amp 24 Volt - 115 Amp 24 Volt - 115 Amp

NOTE! Performance may vary up to -10% due to motor and system efficiency tolerance. The performance shown represents nominal values obtained under typical operating conditions. NOTE! These products and specifications are subject to change without notice.

F-code Section C-code

PS M2.0 Technical Service Data

Version no T-code

000 HMX,RMX

This article is from: