1 minute read

Inspection

Next Article
Disassembly

Disassembly

F-code Section C-code

PS M6.2 6140 Lift Pump Assembly

Version no T-code

001

3. Inspection

NOTE!CLEANLINESS! Perform procedures in a clean environment. Make sure all parts are cleaned before disassembly and kept clean during assembly. 1.Thoroughly clean all parts and remove all nicks and burrs with emery cloth.

WARNING

Be extremely careful when working with solvent. Even a small explosion or fire could cause injury or death.

WARNING

Compressed air used for cleaning MUST be reduced to less than 30 psi. and then only with effective chip-guarding and personal protective equipment.

2.Inspect all parts for excessive wear or scoring. If heavy scoring is found replace part. 3.Inspect inlet strainer (21) for clogging or excessive wear. Wash in solvent and air dry from inside out. 4.Inspect inlet tube (22) for clogging or excessive wear. Wash in solvent and air dry. 5.Inspect inside edges of reservoir (18) for any burrs or nicks that may cut the O ring (11) during installation. Wipe inside of reservoir (18) clean. 6.Clean and inspect valve cavity to be sure it is free of all foreign matter. Inspect solenoid operated valve (2) strainer.

CAUTION

DO NOT bend or apply pressure to center stud or hold cartridge body any place but on flat sides of sub-assembly.

7.Inspect hydraulic hose and replace if worn.