Document Revision History
V7 Software
-Inclusion of ASQ Gate Parameters and subsequent adjustment to ASQ parameters.
-TCC ret.ram0 parameters and timeout parameters included.
- RCP BSL Push.ext parameter included.
- Default values updated as per software release.
North Goonyella PMCR-V12 Parameter Manual Page 2 - 180 M01676-07 Issue Information
Revision Id Date Description of Change 00 30/10/2013 First Release 01 07/11/2013 Minor software update from Germany 02 09/12/2013 Software update, S_GateAdvAuto notice included for MG shield advance, default parameter value changes for RCP snake
S_turn Main. 03 05/03/2014
and
update.
Name Signature Position
V8 Software update
Auxiliary Functions
Reflect new 4-leg shield.
Subsequent updates to TG 3-leg shield functions.
Bleed Valve included for 4-leg shield.
Auger included for TG 3-leg shield.
Seal2 included for 2-leg transition shield (missed in last manual)
Appendix.
PLC Table Included
Min / Max / Password values removed from parameter descriptions.
Default Parameter listing including Min / Max and Password values now included at end of manual.
PMCR Code plug information updated.
3-4 leg pre-lower functionality examples included.
3-4 leg retry tip functionality examples included. Support type shown in code plug list.
Batch Parameters.
Batch Parameter, ‘AsqMgSeq’, Option 4 included.
Batch Parameter, ‘AsqTgSeq.’ Option 4 and 5 included.
SRB Parameters.
SRB Parameter ‘S_TG adv.type’ parameter included.
SRB Parameter ‘S_GateAdvAuto’ parameter updated.
‘S_RCPpush TAIL’ parameter description updated for new functionality.
‘S_turn TAIL’ parameter updated.
‘S_grp.modeMAIN’ / ‘TAIL’ parameters updated. Prime point Positions display included in SRB menu.
Temporary inclusion of ‘NewPrimePointCom.’.
North Goonyella PMCR-V12 Parameter Manual Page 3 - 180 M01676-07 04
Gate ASQ parameters.
ASQ Gate Parameters removed. Following modules included:-
ASQ MAINGATE PARAMETERS.
ASQ TAILGATE PARAMETERS.
ASQ TG-BUTTRESS PARA.
‘RCanExtStr.’ Parameter included in all gate ASQ menu’s.
ASQ Parameters.
Caving Shield Ramp Group parameters moved into ASQ parameter menu.
‘T26 rear can.ext.’ Parameter included in ASQ menu.
‘ASQ P1 trans.’ description updated.
Flipper parameters.
Flipper overview description included. ‘flp.retrigger’ parameter included.
All Flipper parameters from SRB menu migrated into Flipper menu with description updates.
Flipper parameters included for Gate shield shearer position initiation extension.
TCC parameter changes
Removal of Type 2 TCC sequence and dependant parameters. (e.g. ret.sl2 and ret.sl3)
Removal of ‘TCC ret.ram MT’ and ‘TCC ret.ram TM’ parameters and associated timeout parameters.
New description for ‘TCC ret.ram’
New description for ‘TCC type MT’ and ‘TCC type TM’ parameters.
‘TCC cancel’ trigger included detailing new functionality.
‘TCC PLC Inhibit’ parameter and facewide message has replaced ‘BSL O/Load Monitor’ parameter in service menu. PLC table descriptions updated accordingly for this change.
North Goonyella PMCR-V12 Parameter Manual Page 4 - 180 M01676-07
System parameters
System Parameter / ‘Mastercod’ Note included regarding 2-shield network set up.
Local parameters.
Notice included in Local values recommending switching OFF automatic functions during nonproduction activities.
‘s.seal diff.loc’ parameter included.
Global parameters.
Notice included in Global values recommending switching OFF automatic functions during nonproduction activities.
‘TG diff.adv.’ Parameter included. Auto Flippers description updated.
Anti-collision.
Anti-collision section updated in general. Included the ‘ACORoadwayBlockStroke’ parameter.
‘ACO TCC Mode Gate’ / ‘Face’ parameter descriptions updated.
‘ACO Caving Shield’ / ‘Slide limit’ parameter descriptions updated.
Emergency Stop Menu. Updated Emergency Stop menu descriptions.
Service Parameters.
Service parameter – ‘Overload limit’ description updated.
Service parameter – ‘Rear AFC Monitor’ description updated.
Ret.Bleed tmo parameter included.
‘TCC PLC Inhibit’ parameter replaces ‘BSL O/Load Monitor’ parameter.
North Goonyella PMCR-V12 Parameter Manual Page 5 - 180 M01676-07
29/08/2016
RCP Parameters.
‘RCP Ram Safe’ parameter description updated.
‘RCP extens.TG’ parameter included.
‘RCP Auger tmo’ parameter included.
Conveyor Pullback Parameters.
Conveyor Pullback menu updated to reflect new functionality. New parameters included.
Updated to V10
No change to content.
Update to V11
TCC Functionality Removed
All rear reed rod measured values inactive
All rear pressure tx measured values inactive
All Top Coal Caving Parameters inactive
All RCP Parameters inactive except RCP push parameters.
Global Parameters
Inactive Parameters: ‘Auto TCC’
Local Values
13/07/2017
Inactive Parameters: ‘Auto TCC’, ‘RearConveyorPull’, ‘SRB-RearConveyorPull’
Service Parameters
Inactive parameters: ‘TCC PLC Inhibit’, ‘Overload limit ’, ‘Rear AFC monitor ’
SRB Parameters
Parameters Inactive: ‘S_Save TCC MT’ , ‘S_Save TCC TM’, ‘S_TCC seq #’, ‘S_Save RCP’, S_RCP push MAIN’, S_RCP push TAIL’,
Parameters added: ‘MODE=BIDI’, ‘S_Shr TG seq’,
Description Changed: ‘S_GateAdvAuto’, ‘S_BSL push’
ASQ Parameters
North Goonyella PMCR-V12 Parameter Manual Page 6 - 180 M01676-07
5
6
Inactive parameters: ‘St9 RampGate MG’, ‘St10 RampFace MG’, ‘St11 RampGate TG’, ‘St12 RampFace TG’,
Descriptions Changed: ‘T26 rear can.ext.’
Parameters Added: ‘T25 rear can.ret ’, ‘CavShExt_Loc’
ASQ MAINGATE PARAMETERS:
Inactive Parameters: ‘St6MG rear.can.ret’, ‘St7MG rear.can.ext’, ‘St13MG RCanExtStr.’
Parameters Added: ‘MGCavShExt_LOC’, ‘S30MG preset_1’, ‘S31MG preset_2’, ‘S32MG preset_3’, ‘T31MG_preset_1’, ‘T32MG_preset_2’, ‘T33MG_preset_3’, ‘T34MG_presetDelay’
Decription Changed: ‘T25MG rearCan.ret’, ‘T26MG rearCan.ext’
ASQ TAILGATE PARAMETERS
Inactive Parameters: ‘St6TG rear.can.ret’, ‘St7TG rear.can.ext’, ‘St13TG RCanExtStr.’
Parameters Added: ‘TGCavShExt_LOC’, ‘S30TG preset_1’, ‘S31TG preset_2’, ‘S32TG preset_3’, ‘T26TG rearCan.ext’, ‘T31TG preset_1’, ‘T32TG preset_2’, ‘T33TG preset_3’, ‘T34TG presetDelay’
Descriptions Changed: ‘T25TG rearCan.ret’
ASQ TG-BUTTRESS PARAM.
Inactive Parameters: ‘St6TGB rear.canRet’, ‘St7TGB rear.canExt’, ‘St13TGB RCanExtStr’
Parameters Added: ‘T26TGB rearCanExt’, ‘TGBCavShExt_LOC’, ‘S30TGB preset_1’, ‘S31TGB preset_2’, ‘S32TGB preset_3’, ‘T31TGB preset_1’, T32TGB preset_2’, ‘T33TGB preset_3’, ‘T34TGBpresetDelay’.
Descriptions Changed: ‘T25TGB rearCanRet’
FLIPPER PARAMETERS
Parameters removed: ‘FLPRetVertDist.’, ‘flpret.dist’, ‘flpext.dist’
Parameters Added: ‘FLPRetVertDist.MT’, ‘FLPRetVertDist.TM’, ‘flpret.dist.MT’,
North Goonyella PMCR-V12 Parameter Manual Page 7 - 180 M01676-07
‘flpret.dist.TM’, ‘flpret.dist.MT’, ‘flpret.dist.TM’
RCP Parameters
All parameters inactive except for: ‘RCP BSL accept‘,‘RCP BSL tmo‘ & ‘RCP Auger tmo‘
ANTICOLLISION
Inactive Parameters: ‘ACO TCC mode GATE‘, ‘ACO TCC mode FACE‘, ‘ACO c.sh.limitGATE‘, ‘ACO c.sh.limitFACE‘, ‘ACO c.slide limit‘, ‘TCC slowdn. Start‘, ‘TCC slowdn. Stop‘, ‘TCC start speed‘, ‘TCC Shr.Buf.start‘, ‘TCC Shr.Buf.stop‘
MAINGATE BUTTRESS PARAMETERS
Inactive Parameters: ‘MGB RCP INT’, ‘MGB RCP INT Limit’, ‘MGB RCP/BP suspend’, ‘MGB RCP/BP protect’, ‘MGB BP NBprot.Master’
For
North Goonyella PMCR-V12 Parameter Manual Page 8 - 180 M01676-07
07 29/09/2017
V12 Removed Inactive Parameters
default parameter list ‘flpext.dist.TM’ & ‘flpext.dist.MT’ were named incorrectly. Signatories 01 02 03 04 05 06 Prepared P Long P Long P Long P Long P Long C Davis Reviewed P Schumer J Hamilton J Hamilton J Hamilton P Clamp P Clamp Approved J Hamilton J Hamilton J Hamilton P Clamp P Clamp 07 08 09 10 11 12 Prepared C Davis Reviewed P Clamp Approved
Corrected
North Goonyella PMCR-V12 Parameter Manual Page 9 - 180 M01676-07 CONTENTS Issue Information ................................................................................ 2 Document Revision History ............................................................... 2 Signatories ..............................................................................................................8 PMC-R Menu Navigation ................................................................ 11 Menu Plan 11 PMC-R Menu Headings 12 Short-cut Keys.......................................................................................................13 Changing Parameters ....................................................................... 17 Numeric Parameters 17 Text Parameters....................................................................................................17 Parameter Descriptions 18 Remote Operation 18 Auxiliary Functions 22 Operation 22 Example of an Auxiliary Function 22 Special Auxiliary Functions .......................................................................................... 22 Measured Values ..................................................................................................24 System Parameters 27 Error Messages .....................................................................................................29 Global Parameters 36 Local Values 40 Service Parameters...............................................................................................45 SRB Parameters (Shearer Random Batch) 49 ASQ Parameters ...................................................................................................60 ASQ MAINGATE PARAMETERS 68 ASQ TAILGATE PARAMETERS 77 ASQ TG-BUTTRESS PARA..................................................................................86 Batch Parameters 95 Rear Conveyor Pull Parameters............................................................................99 Bankpush Parameters 100 Conveyor Pullback Parameters 104 PSA Parameters .................................................................................................107 Flipper Parameters 109 Position Spray Parameters .................................................................................114 Caving Spray Parameters 117 Goaf Spray Parameters 118 Side Spray Parameters .......................................................................................120 Walkway Water Spray Parameters 122 Canopy Spray Parameters ..................................................................................124 Travel Zone Parameters .....................................................................................126 Anticollision Parameters 127 Line Parameters ..................................................................................................131 Roadway Shields Parameters 133 Buttress Shields Parameters 138
North Goonyella PMCR-V12 Parameter Manual Page 10 - 180 M01676-07 Windblast Parameters ......................................................................................... 143 Valve Cycle Count Parameters 145 Emergency Stop 146 Diagnostics ......................................................................................................... 148 APPENDIX: ..................................................................................... 158 Server LED Indications 158 PMC-R code plug information ............................................................................. 159 PLC Tables 160 3-4 Leg Shields Pre-Lower Functionality Examples 162 3-4 Leg Shields Retry Tip Functionality Examples .............................................. 164 Parameter List 165
PMC-R Menu Navigation
By pushing the key ‘R’ or ‘K’ keys it is possible to select different menus. The selected menu is shown in the LCD information display.
By pushing the key ‘L’ or ‘M ’ it is possible to scroll up and down the menu to select various menu displays. These displays provide information on the functioning of the PMC-R system or allow the user to alter parameters affecting the operation of the PMC-R system.
Menu Plan
North Goonyella PMCR-V12 Parameter Manual Page 11 - 180 M01676-07
Figure 1 Menu Structure in PMC-R
PMC-R Menu Headings
AUXILIARY FUNCTIONS
IDLE DISPLAY
MEASURED VALUES
SYSTEM PARAMETER
ERROR MESSAGES
GLOBAL PARAMETER
LOCAL VALUES
SERVICE
SRB PARAMETERS
ASQ PARAMETER
ASQ MAINGATE PARAMETERS
ASQ TAILGATE PARAMETERS
ASQ TG-BUTTRESS PARA.
BATCH PARAMETER
TCC PARAMETERS
REAR CONVEYOR PULL
BANKPUSH PARAM.
CONV PULLBACK
PSA PARAMETER
FLIPPERS
POSITION SPRAY
GOAF SPRAY
CANOPY SPRAY
CAVING SPRAY
SIDE SPRAY
WALKWAY SPRAY
TRAVEL ZONE PARAMETER
ANTICOLLISION
LINE PARAMETER
ROADWAY SHIELDS PARAMETERS
BUTRESS SHIELDS PARAMETERS
WINDBLAST
VALVE CYCLE COUNT
EMERGENCY STOP
DIAGNOSTIC
North Goonyella PMCR-V12 Parameter Manual Page 12 - 180 M01676-07
Short-cut Keys
Short-cut keys can be used to access menu displays directly, these are:
Stops all automatic functions on the face
Stop of all automatic functions on the face
Cancel of the input
No function Start key for automatic/adjacent auto sequence functions
Input of number U
Select the adjacent SCU to the LEFT. Accesses Auxiliary Functions Menu
Select the adjacent SCU to the LEFT. Adjacent SCU goes into slave mode
Input of letter H
Select the adjacent SCU to the RIGHT. Accesses Auxiliary Functions Menu
Select the adjacent SCU to the RIGHT. Adjacent SCU goes into slave mode
Input of letter I
Switches `Positive Set Automatic’ (PSA) on / off Selects the PSA menu.
Automatic key Manual trigger for Positive Set function to set shield
No Function Selects Batch group to the LEFT (View to SCU)
No Function Selects batch group to the RIGHT (View to SCU)
Input of number 0
Automatic key
Input of letter G
Hot key
access to bank pull rear conveyor
Press twice = Lock on pull
LED On = RCP Complete.
LED Off = RCP Required
Automatic key advance rear conveyor (Deadman Key)
access rear conveyor menu
Input of letter G
Input of number 6
Automatic key
North Goonyella PMCR-V12 Parameter Manual Page 13 - 180 M01676-07
Keyboard symbol Idle mode Work mode Input mode
• Thank you very much for reading the preview of the manual.
• You can download the complete manual from: www.heydownloads.com by clicking the link below
• Please note: If there is no response to CLICKING the link, please download this PDF first and then click on it.
CLICK HERE TO DOWNLOAD THE COMPLETE MANUAL
CLICK HERE TO DOWNLOAD THE COMPLETE MANUAL