NBC Air Filtration Unit

OUTSIDE 35 C HUMIDITY 90%

22ยบ C

Inside

PROVIDED BY HEINEN & HOPMAN

Heating

Ventilation

Air Conditioning

Refrigeration


INTRODUCTION Naval vessels have to operate now a day more and more under the threat of an attack by TIC’s and TIM’s. To be able to operate under these circumstances without being contaminated, reliable NBC filter systems are of the essence. With our NBC filter units, provided with STANAG4447 filter elements, in combination with our

overpressure controllers, a safe operating environment (citadel) is created, ensuring the optimal performance of the crew and electronic equipment. Our NBC filter units are available in a capacity range of 900 up to 1800m3/h.

APPLICATION Our nuclear, biological and chemical (NBC) filtration system provides clean filtered fresh air, free from NBC contaminates in an over pressure citadel. Three levels of filtration (coalescer, dust, and composite filtration) is applied to incoming air before being supplied to the citadel. The over pressure citadel removes the need for occupants to wear gas masks and protective clothing during NBC attacks. Two modes of operation allows clean fresh air to be supplied during peace time, or conventional combat times, and filtered fresh air during NBC warfare. The control system constantly compares inside and outside pressures, and should the citadel pressurization fail, provide a visual and/or audible warning. The NBC filter unit is designed for external installation to citadels with a supply duct to the citadel interior. The NBC control unit is designed to be installed internally within the citadel covering the air duct to diffuse air entering the citadel. When the NBC filter unit is operational the unit is designed as a fail-safe system, i.e. should the unit sustain damage or an air seal leak, then clean air will leak out of the unit rather than contaminated air being drawn in.

KEY FEATURES • • • • • • • • • • •

Unique innovative design; Smart and powerful NBC / TIM Filter clamping system; Easy service and maintenance access; Compact and lightweight; Completely closed system; Doors equipped with end switches Analyzed for gas tightness, shock, vibration and EMC; High shock resistance. Up to 60g vertical Design according NATO standard; Design according STANAG 4447; NBC Filter capacity 900, 1200 and 1800m³/h.


FUNCTIONING


AFU 1800 & AFU 1200

Technical Data AFU-1800 50Hz / 60Hz Air quantity

1.800m3/h

Pst

1.000Pa

Execution

SS316L

Filters

6pcs

Power supply fan

3x380V-50Hz / 3x440V-60Hz

Rated power

4.0kW / 4.8kW

Power supply heater

3x380V-50Hz / 3x440V-60HZ

Capacity

10kW

Power supply valves

1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters)

1.350kg

Weight (excl. NBC filters)

1.170kg

Control panel (separate delivery)

760x760x300mm

Technical Data AFU-1200 50Hz / 60Hz Air quantity

1.200m3/h

Pst

1.000Pa

Execution

SS316L

Filters

4pcs

Power supply fan

3x380V-50Hz / 3x440V-60Hz

Rated power

4.0kW / 4.8kW

Power supply heater

3x380V-50Hz / 3x440V-60HZ

Capacity

10.5kW

Power supply valves

1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters)

1.350kg

Weight (excl. NBC filters)

1.170kg

Control panel (separate delivery)

760x760x300mm


AFU 900

Technical Data AFU-900 50Hz / 60Hz Air quantity

900m3/h

Pst

1.000Pa

Execution

SS316L

Filters

3pcs

Power supply fan

3x380V-50Hz / 3x440V-60Hz

Rated power

2.6kW / 3.12kW

Power supply heater

3x380V-50Hz / 3x440V-60HZ

Capacity

10.5kW

Power supply valves

1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters)

900kg

Weight (excl. NBC filters)

810kg

Control panel (separate delivery)

760x760x300mm

Alternatives available on request. Owing to continuous product development Heinen Hopman reserves the right to introduce alterations without prior notice.


Brazil T: +5521 3587 4241/4244 E: info@br.heinenhopman.com France - La Ciotat T: +334 4204 8685 E: info@heinenhopmanfrance.com France - Grasse T: +336 3090 7786 E: info@heinenhopmanfrance.com Germany T:+49 4073 1680 E: info@drewsmarine.com

India T: +9133 6499 1293 E: info@heinenhopmanindia.com Italy T: +3901 8745 7970 E: info@it.heinenhopman.com The Netherlands (HQ) T: +313 3299 2500 E: info@heinenhopman.com The Netherlands (Rotterdam) T: +317 8890 8050 E: binnenvaart@heinenhopman.nl

Norway T: +47 6919 0900 E: admin@teknotherm.no Peoples Republic of China T: +8621 3253 2896 E: info@cn.heinenhopman.com Peoples Republic of China T: +86 510 8528 1763 E: ivo.klaric@teknotherm.no Poland T: +489 1433 1800 E: tmh@teknotherm.no

Romania T: +402 3644 8222 E: office@ro.heinenhopman.com Russia T: +7 (4012) 308 801 E: info@heinenhopman.ru Singapore T: +65 6897 7879 E: info@sg.heinenhopman.com South Korea T: +8270 4901 0000 E: info@kr.heinenhopman.com

Spain T: +349 3225 9668 E: info@es.heinenhopman.com Sweden T: +46 3121 7500 E: mats.uden@teknotherm.no Turkey T: +9021 6493 8118 E: info@tr.heinenhopman.com UAE (Abu Dhabi) T:+971 2550 4147 E: info@caspuae.com

UAE (Dubai) T: +971 4263 5453 E: info@caspuae.com USA - Fort Lauderdale, Florida T: +195 4463 0110 E: info@arwmaritime.com USA - Houma, Louisiana T: +198 5876 7989 E: leblanc@leblancandassociates.com

Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions. Visit greenmanifest.info for more information.

www.heinenhopman.com

NBC Air Filtration Unit  

Naval vessels have to operate now a day more and more under the threat of an attack by TIC’s and TIM’s. To be able to operate under these ci...

NBC Air Filtration Unit  

Naval vessels have to operate now a day more and more under the threat of an attack by TIC’s and TIM’s. To be able to operate under these ci...