1,650
200
200
200 200
300 200 200
200 200 200
2,050
1,650
200
Movement area Movement 600/800 area 600/800 2,050
300
3
1,550 350 350 350 350
200
600
1,150
300 200 200
200 200
200
1,150
300 200 200
1,550
c
300
300
Movement area 600/800
200
200
1,150
200
2,050
200
Partition
1,150
200
200
350 350 350 350
Movement area 600/800
300
300 200
200
Movement area 600/800
200
600
600
Movement area 600/600
1,650
Partition 1,650
Partition 200
450
600 600 350 350 350 350 600 350 350 350 350
1,550
d
450
600
350 350 350 350 200
200 200
200
200
MovementMovement area area 600/800 600/800
003
200 200 003
600
1,650
Partition
2,000
300
2,000
1,250
1,250
200
200
200
1,250
450
450 800 800
800
Movement area 600/800
Movement area 600/800
800
450
200
800
300
800
8
200
1,000
Movement area 600/800
7
ange washbasin in sanitary facilities at BMW R Welt, Munich (D) 2007, Coop Himmelb(l)au Minimum number of toilets including urinals, hand washing facilities (acc. to the ASR) Toilet in compliance with the ASR: a Toilet with a single row of toilets, doors open inwards b Toilet with a single row of toilets c Toilet with a single row of toilets and urinals, doors open inwards d Toilet with a single row of toilets and urinals e Toilet with a double row of toilets, doors open inwards f Toilet with a double row of toilets g Washroom
31
003 00
6
1,000
8 g
200 200
200
200 200
200
f
e
1,000
200
300
300
MovementMovement area area 600/800 600/800
00
200
600
Partition 1,550
200
450
Movement area 600/600
450 600
Equipment
Toilet cubicles must be lockable from inside. In the cubicle, a clothes hook, toilet paper and toilet brush must be provided, and rubbish bins with lids in women’s toilets. Soap and a means of drying the hands (e.g. disposable hand towels, cloth towel dispenser or a warmair dryer) and rubbish bins must be provided with hand washing basins. Washing and shower areas must have hot and cold running water in drinking water quality, as defined in the Drinking Water Ordinance (Trinkwasserverordnung), as well as soap holders and towel rails. A hand rail should also be installed in shower areas. Facilities for drying towels and drying the hair may also be required. In shower areas with no direct access to a changing room, receptacles for clothes must be provided in the dry area. At least one seat for every four employees who use the room at the same time must be provided in changing rooms. Sufficiently large, ventilated and lockable lockers with receptacles for clothes must be provided for storing clothing. The work and protective clothing and personal
200
200 200
b
200
ASR A4.1 stipulates that a movement area in front of toilets or urinals is required in toilets or toilet cubicles. It should be symmetrically positioned in front of the toilets and urinals. The minimum dimensions shown in Fig. 10 must be complied with for toilets. The direction in which the door opens must also be taken into account. A door that opens outwards is generally preferable because it allows easier access to people in emergencies (Fig. 8). The partition walls and doors of toilet stalls must be at least 1.90 m high. If partition walls and /or doors are not flush with the floor, the distance between the floor and door’s lower edge must be 10 to 15 cm.
200
300
Partition
a
450
Movement area 600/600
Movement area Movement 600/800 area 600/800
200
Movement area 600/800
200
1,250
Movement area 600/800
Partition
Partition
300
300 200
350 350 350 350
200
200
600
Partition
Partition
600
Movement area Movement 600/600 area 600/600
planning criteria for public sanitary facilities
2,050
1,650
Partition
Fundamental 600 350 350 350 350 600 600 350 350 350 350
450 600
450
450
350 350 350 350
600
600
450
600
1,150 600 350 350 350 350 2,050
450