Air Motors - Critical Maintenance after each use

Page 1


Air Motors - Critical maintenance after each use

Place Horizontally 1

Maintain after each use

After each use of the air tools, the motors MUST be maintained properly to prevent internal corrosion and malfunction from water and condensation in the high pressure air. Maintenance MUST be performed immediately after each use on a daily basis.

Dismount motor from tool and place horizontally. Or place motors with tool horizontally.

Applies for [HPT0014] Hull Brush Tool

Flush with Oil

Blow air into the motor through L or R use 2-3 bar pressure with a short hose. While blowing air into the motor in 2-3 min, pour 50 ml air lubrication oil into the motor.

Ø8 mm Plugs [MHH0154]

x3

With some oil still inside the motor, plug all three holes, to prevent remnants, salt mist and corrosion before next use.

Applies for [HPT0013] Cement Cleaning Tool