HALL OF DEMOCRACY DEVELOPMENT DOCUMENTATION - 40 GEORGE STREET, BRISBANE CBD, 4000, QLD, AUSTRALIA DEVELOPMENT SUMMARY
www.autodesk.com/revit
ABBREVIATIONS DRAWING SCHEDULE
PROPERTY NO: LOT/DP: PARISH: SITE AREA: ZONING: BUILDING CLASS:
40 2B32444 BRISBANE CITY 6491m2 PRINCIPAL CENTRE 9B
PROPSOED BUILDING GFA BASEMENT GFA: GROUND FLOOR GFA: LEVEL 1 GFA: LEVEL 2 GFA: TOTAL BUILDING GFA:
3130 m2 1399 m2 1836 m2 1589 m2 7954 m2
PARKING SPACE INFORMATION PARKING BAY: PWD PARKING BAY: MOTORBIKE PARKING: TOTAL PARKING SPACE: BICYCLE PARKING SPACE:
55 5 13 73 35
GENERAL NOTE 1. ANY DEVELOPMENT AND CONSTRUCTION SHOULD NOTIFY ALL RELEVANT LOCAL AUTHORITY DEPARTMENTS FOR CONNECTION AND SEALING PROCEDURES OF EXITING SERVICES SUCH AS DRAINAGE, GAS, CABLE, WATER SUPPLY,ETC. 2. ANY CONSTRUCTION WORKS ON SITE SHOULD COMPLY WITH RELEVANT AUSTRALIAN STANDARDS, NATIONAL CONSTRUCITON CODE AND BRISBANE CITY COUNCIL 3. ALL NEIGHBOURING PROPERTY AND OWNERS SHOULD BE NOTIFIED OF THE BUILDING DEVELOPMENT DURATION BEFORE CONSTRUCTION 4. ALL DISPARITY DURING THE PLANNING AND CONSTRUCTION STAGES OF THE BUILDING SHOULD NOTIFY THE ARCHITECT AND CONTRACTOR 5. ALL DRAWINGS SHOULD COMPLY WITH REQUIREMENTS AND LEGISLATION AS OUTLINED IN AUSTRALIAN STANDARDS, NATIONAL CONSTRUCTION CODE, AND BRISBANE CITY COUNCIL 6. CONSTRUCTION SHOULD HAVE A MINIMUM OF 2m CLEARANCE FROM COUNCIL SEWER AND STORMWATER MAINS EXCEPT THERE IS SPECIFIC APPROVEMENT 7. DRAWINGS TO BE UNDERSTOOD BY REFFERING TO THE STRUCTURAL, MECHANICAL, ELECTRICAL, HYDRAULIC AND FIRE ENGINEER DETAILS 8. ALL NECESSARY CONSTRUCTION AND EXPANSION JOINTS REFER TO STRUCTURAL ENGINEER SPECIFICATIONS 9. ALL PIPING DIMENSIONS, CONFIGURATION AND INSTALLATION OF ANY WATER SYSTEM REFER TO HYDRAULIC ENGINEER SPECIFICATIONS 10. ALL DRAWINGS ARE DRAWN IN A0 SIZE SHEETS 11. DIMENSIONS ARE ALL WRITTEN IN MILLIMETRES UNLESS INDICATED OTHERWISE
BICYCLE PARKING GLASS BALLUSTRADE WITH STEEL FRAME CEILING LEVEL STRUCTURAL COLUMN TYPE 1 - 450 X 850mm RECTANGULAR CONCRETE COLUMN STRUCTURAL COLUMN TYPE 2 - 300mm CIRCULAR CONCRETE COLUMN STRUCTURAL COLUMN TYPE 3 - 200 X 800mm RECTANGULAR BLADE COLUMN STRUCTURAL COLUMN TYPE 4 - 500 X 150mm VERTICAL STEEL COLUMN CONCRETE WALL FINISH END OF TRIP FACILITY FIRE EXTINGUISHER FINISH FLOOR LEVEL FIRE HYDRANT SINGLE VALVE FIRE HOSE REEL FIRE RESISTANCE LEVEL FLOOR WASTE MOISTURE RESISTANT PLASTER BOARD PLASTER BOARD PLASTERBOARD WALL FINISH PEOPLE WITH DISABILITY WATER CLOSET RELATIVE LEVEL STRUCTURAL SLAB LEVEL TOP OF WALL TACTILE GROUND SURFACE INDICATOR
BP BAL-01 CL COL1 COL2 COL3 COL4 CWF E.O.T FE FFL FH FHR FRL FW MPB PB PWF PWD WC RL SSL T.O.H TGSI
A000 A001 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112
WALL TYPE
A113
WT-01 WT-02 WT-03 WT-04 WT-05 WT-06
A115
A114
300mm CONCRETE WALL 64mm METAL STUD WALL WITH TILE FINISH 92mm METAL STUD WALL WITH FIBRE CEMENT FINISH 200mm CONCRETE BLOCK WALL 300mm CONCRETE BLOCK WALL 32mm DOUBLE GLAZED CURTAIN WALL
A116 A117
SITE LOCATION
A118 A119
DRAWING SYMBOLS
A120 A121
E
E
ELECTRICAL SUPPLY
FC
FC
FIBRE OPTIC CABEL
A123
G
G
GAS SUPPLY
A124
Se
Se
SEWAGE DRAIN
W
W
WATER SUPPLY
A122
A125 A126
E
A127 A128
ELECTRICAL CONNECTION
A129
FC
FIBRE OPTIC CONNECTION
Se
SEWAGE CONNECTION
W
WATER SUPPLY CONNECTION
A130 A131 A132 A133 A134
EMERGENCY LIGHTING
A135
FIRE ALARM
A136 A137
SMOKE DETECTOR CAPSULE LIGHTING - LED - LSI_INDUSTRIES
BUILDING OVERVIEW
A138 A139 A140
DISCLAIMER 1. THE REPRODUCTION, COPYING AND DISTRIBUTING THIS DRAWING HARD COPY SET OR THE ELECTRONIC DATA SET WITHOUT THE PERMISSION OF LW&TK DESIGN IS PROHIBITED 2. NO RESPONSIBILITY FOR THE ACCURACY OR FOR ANY CONSEQUENCE RESULTING FROM THE USE OF ALTERNATION OF THIS INFORMATION IS ACCEPTED 3. CONTRACTORS SHALL VERIFY JOB DIMENSIONS BEFORE COMMENCING ANY WORK. DO NOT SCALE OFF THIS DRAWING - USE FIGURED DIMENSIONS 4. THE DRAWING SHOULD BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS AND SPECIFICATIONS. COPYRIGHT OF THE DRAWING AND ALL WORKS EXECUTED FROM SUCH REMAIN THE PROPERTY OF THE ARCHITECT
LIGHTING_CEILING - MOUNTED 1300X100X100 ELECTRIC CABLE PATH EMERGENCY LIGHTING ELECTRIC CABLE PATH
A141 A142 A143 A144 A145
EMERGENCY EXIT SIGNAGE EMERGENCY EXIT SIGNAGE LEFT
Sheet Name PROJECT COVER PAGE
Drawn By
H.Y.K & M.H.W CODE COMPLAINCE H.Y.K & M.H.W SITE INFRASTRUCTURE H.Y.K & PLAN M.H.W SITE PLAN H.Y.K & M.H.W BASEMENT FLOOR PLAN H.Y.K & M.H.W BASEMENT ROOM SETOUT H.Y.K & PLAN M.H.W GROUND FLOOR PLAN H.Y.K & M.H.W GROUND FLOOR ROOM H.Y.K & SETOUT PLAN M.H.W LEVEL 1 FLOOR PLAN H.Y.K & M.H.W LEVEL 1 ROOM SETOUT H.Y.K & PLAN M.H.W LEVEL 2 FLOOR PLAN H.Y.K & M.H.W LEVEL 2 ROOM SETOUT H.Y.K & PLAN M.H.W ROOF PLAN H.Y.K & M.H.W BASEMENT RCP H.Y.K & M.H.W GROUND FLOOR RCP H.Y.K & M.H.W LEVEL 1 RCP H.Y.K & M.H.W LEVEL 2 RCP H.Y.K & M.H.W HVAC H.Y.K & M.H.W HVAC H.Y.K & M.H.W HVAC H.Y.K & M.H.W HVAC H.Y.K & M.H.W BASEMENT EGRESS PLAN H.Y.K & M.H.W GROUND FLOOR EGRESS H.Y.K & PLAN M.H.W LEVEL 1 EGRESS PLAN H.Y.K & M.H.W LEVEL 2 EGRESS PLAN H.Y.K & M.H.W CROSS SECTION 1-1 H.Y.K & M.H.W CROSS SECTION 1-2 H.Y.K & M.H.W CROSS SECTION 2-1 H.Y.K & M.H.W CROSS SECTION 2-2 H.Y.K & M.H.W CROSS SECTION 3-1 H.Y.K & M.H.W CROSS SECTION 3-2 H.Y.K & M.H.W CROSS SECTION 4-1 H.Y.K & M.H.W CROSS SECTION 4-2 H.Y.K & M.H.W CROSS SECTION 5-1 H.Y.K & M.H.W CROSS SECTION 5-2 H.Y.K & M.H.W CROSS SECTION 6-1 H.Y.K & M.H.W CROSS SECTION 6-2 H.Y.K & M.H.W ELEVATION H.Y.K & M.H.W ELEVATION 2 H.Y.K & M.H.W BASEMENT FIRE STAIR 01 H.Y.K & DETAILS M.H.W BASEMENT FIRE STAIR 02 H.Y.K & DETAILS M.H.W GROUND FLOOR FIRE H.Y.K & STAIR 01 DETAILS M.H.W GROUND FLOOR FIRE H.Y.K & STAIR 02 DETAILS M.H.W GROUND FLOOR FIRE H.Y.K & STAIR 1 & 2 DETAILS M.H.W LIFT CORE 1&2 DETAILS H.Y.K & M.H.W PWD DETAILS Author CONSTRUCTION DETAILS H.Y.K & M.H.W CONSTRUCTION DETAILS H.Y.K & M.H.W
Checked By ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN ROBERT TAKKEN Checker ROBERT TAKKEN ROBERT TAKKEN
Project Address 40 GEORGE STREET, BRISBANE, QLD 4000
CLIENT: GREVIOUS KEPPLER PROJECT: HALL OF DEMOCRACY
PROJECT COVER PAGE DAH811
Project number Date
Drawn by Checked by
EMERGENCY EXIT SIGNAGE RIGHT
Issue Date H.Y.K & M.H.W ROBERT TAKKEN
A000
EGRESS DIRECTION Scale
1 : 100
2/11/2020 9:13:52 PM
PROPERTY INFORMATION
Sheet Number